  1. Replies
    3
    Views
    176

    Technically everything can be done through a...

    Technically everything can be done through a terminal. I don't know what rep you are talking to but they don't know what they are talking about. Basically you can do it 1 of 2 ways. You can use a P2...
  2. Replies
    3
    Views
    176

    There is no reason that the JCI Devices cannot be...

    There is no reason that the JCI Devices cannot be used on a Siemens system. Are you trying to replace the FX60 or use it as a router? The MSTP part might be tricky as I know that with the FEC line...
  3. Thread: JCI lon

    by NickDeal
    Replies
    7
    Views
    993

    Yes, you can use any brand Lon network management...

    Yes, you can use any brand Lon network management tool though it is better to have the original network configuration if possible.
  4. Thread: JCI lon

    by NickDeal
    Replies
    7
    Views
    993

    You replaced the NAE but probably didn't...

    You replaced the NAE but probably didn't commission it on to the LON network. This must be done with a network management tool like LN-Builder 3, which was probably used to startup the job to begin...
  5. The last version for a -0 is 4.0.6 or something...

    The last version for a -0 is 4.0.6 or something like that. 4.1 wouldn't go on a -0.
  6. Replies
    3
    Views
    592

    CFM = SQRT ($AVGSVP) * 4.005 * SQFT * (SAF .EQ....

    CFM = SQRT ($AVGSVP) * 4.005 * SQFT * (SAF .EQ. PRFON)

    Where $AVGSVP is the average or current velocity pressure and SQFT is the square foot of your duct. The last part prevents the equation from...
  7. Replies
    2
    Views
    376

    You cannot setup a trend using commander. You...

    You cannot setup a trend using commander. You need to use the Trend Definition Editor. Use the wizard (looks like a wizard hat) to make the trend and setup all of the steps. Attached is the icon for...
  8. Replies
    5
    Views
    488

    Just use an Analog Value, a Mux block and a...

    Just use an Analog Value, a Mux block and a timer. Add the AV as an input and output, connect the input to one side of the Mux block, and your trended point to the other input on the Mux block. Set...
  9. Replies
    5
    Views
    488

    You should be able to do that with LCT pretty...

    You should be able to do that with LCT pretty easily.
  10. Replies
    2
    Views
    480

    You should only need to create the...

    You should only need to create the MetasysExpertPreferences.xml file in your user profile on the machine you are using.
  11. Thread: Need help!

    by NickDeal
    Replies
    3
    Views
    256

    This forum is more for Commercial control...

    This forum is more for Commercial control systems, but depending on where you live and the heat load in your home will decide on the size of unit that you need. If you live in a hot climate and your...
  12. Replies
    10
    Views
    480

    To actually answer your question, no the M5...

    To actually answer your question, no the M5 software cannot run on Windows 7 or 2008 32-bit. It actually won't even run on Windows XP SP3. You have to have SP2 or lower, preferably SP1 as there are...
  13. Replies
    8
    Views
    442

    http://www.adafruit.com/products/50

    http://www.adafruit.com/products/50
  14. Replies
    40
    Views
    2,700

    Sounds like a JCI tech. When I worked for JCI...

    Sounds like a JCI tech. When I worked for JCI doing a Modbus integration was expensive. You had basically 2 blessed and readily available options. 1 was to go to Field Server and get a preconfigured...
  15. Replies
    2
    Views
    187

    This is an issue with older firmware. The only...

    This is an issue with older firmware. The only way the an AI point can be commanded in BACnet is by putting it Out of Service. The TEC needs to do this in order to update the value. This is normal...
  16. Replies
    10
    Views
    783

    Rip it out and start over. Hopefully the district...

    Rip it out and start over. Hopefully the district has a decent set of installation drawings (doubtful). If they are using a machine that operated in the 80s the controls on the units can't be very...
  17. How many devices are on the NAE? What type of...

    How many devices are on the NAE? What type of NAE? Have you tried disconnecting a few of the other cards and seeing if the discovery improves? What is the bus health of the MSTP trunk?
  18. Replies
    5
    Views
    407

    What's the bus health look like? Did you check...

    What's the bus health look like? Did you check the voltages of the wires to make sure that there is not something else going on? I had this issue once and it turned out to be a bad FEC. Didn't figure...
  19. Replies
    7
    Views
    596

    A Siemens LA546 Laboratory Electronic Actuator...

    A Siemens LA546 Laboratory Electronic Actuator can provide that. Goes faster than 5 seconds and is bloody expensive.
  20. Replies
    10
    Views
    601

    The CVT will allow you to connect to the Zone Bus...

    The CVT will allow you to connect to the Zone Bus of the controllers and the thermostats. If you have a lot of VAV controllers that you will be working on they the CVT is the better option as the USB...
  21. Replies
    4
    Views
    412

    http://www.echelon.com/resource-library-results?fi...

    http://www.echelon.com/resource-library-results?filters=software,software_downloads&ps=20
  22. Replies
    26
    Views
    5,088

    Hate to bring up an old thread, but if anyone has...

    Hate to bring up an old thread, but if anyone has a copy of this software it would be greatly appreciated,
  23. There isn't. Once you delete the reference from...

    There isn't. Once you delete the reference from the ADX/NAE database it shouldn't remove the data from the database but it will remove the reference that the SQL queries use to show the data. If you...
  24. Replies
    11
    Views
    812

    Depending on your area, the branch, and your...

    Depending on your area, the branch, and your level of experience it will either be sink or swim, or you might get lucky. When I started with JCI I was hired on a Friday and told to be on site Monday...
  25. Thread: 3 home owner

    by NickDeal
    Replies
    2
    Views
    403

    The Controls forum is for Building Automation...

    The Controls forum is for Building Automation Controls. Large scale HVAC systems. I don't believe this is the proper forum for home appliances.
  26. Replies
    4
    Views
    390

    Er, if you NUT the NAE it will completely erase...

    Er, if you NUT the NAE it will completely erase the NAE's database. I am assuming you have a SCT backup. You can use 2.2 or even 2.3 and it shouldn't affect the functionality of the NAE.
  27. Replies
    4
    Views
    390

    Jebus, why would you want that? Up until version...

    Jebus, why would you want that? Up until version 2.3 Metasys was buggy as hell. Not that 2.3 was much better. Best I can do is 2.2.
  28. Replies
    9
    Views
    1,049

    What type of TECs? Are they being commanded from...

    What type of TECs? Are they being commanded from PPCL or some other process? How old are the TECs? If you delete and readd the TEC to the system profile is does this continue?
  29. Replies
    4
    Views
    437

    No idea on the sourcing of TECs. Most customers...

    No idea on the sourcing of TECs. Most customers that I have seen have either found places the sell them or for the most part just order them through Siemens as they are backwards compatible and still...
  30. Replies
    4
    Views
    437

    Depending on the model of TEC and what it is...

    Depending on the model of TEC and what it is setup for you may or may not have a good road for this other than ripping out the controllers and installing new ones.

    Almost all of the new TEC...
  31. Replies
    13
    Views
    1,558

    The application files are built into the TEC's...

    The application files are built into the TEC's firmware. You don't need any additional files. WCIS stores text files for the different applications on the local machine but they are mainly for speed....
  32. Replies
    12
    Views
    2,087

    No the ADX software won't talk to BACnet. It uses...

    No the ADX software won't talk to BACnet. It uses SOAP connections to talk to the NAEs. The NAE-8500 series, which is an NAE engine working on a server machine, can do BACnet but not do everything...
  33. Replies
    12
    Views
    2,087

    The ADX does not support BACnet natively nor does...

    The ADX does not support BACnet natively nor does it support OPC that I have ever seen. JCI just came out with a product called ODS which is a BACnet operator workstation. Otherwise you would need to...
  34. Bigguy158 you are correct. Looked back at my...

    Bigguy158 you are correct. Looked back at my files. 1.6.0_21 is for 5.1. But IE 10 will not work at all. I am pretty sure that is your main issue.
  35. Thread: METASYS ADS

    by NickDeal
    Replies
    31
    Views
    2,797

    If you log into the NAEs under the NAE focus tab...

    If you log into the NAEs under the NAE focus tab in Advanced View it will show if the ADS is online to the NAE. To check whether you are using DHCP you need to log into the NAE and under the network...
  36. Metasys at the version you are at, guessing from...

    Metasys at the version you are at, guessing from the Java version 4.1, was never designed to run on IE 10. They are very specific about browser version with Metasys. I am assuming it is a 32 bit...
  37. Thread: METASYS ADS

    by NickDeal
    Replies
    31
    Views
    2,797

    Is the ADS online to the NAEs? Has something...

    Is the ADS online to the NAEs? Has something recently changed like an upgrade, IP address, NAE Name? Have any firewall ports been recently changed on the network?
  38. Replies
    4
    Views
    580

    Depending on the version of the NAE it required a...

    Depending on the version of the NAE it required a certain IE version to work. Before they switched to the Launcher I think the highest it would go is IE8.
  39. Replies
    30
    Views
    7,029

    There is not a way to get a value from Insight or...

    There is not a way to get a value from Insight or a panel unless you are storing the value locally. The panels don't store any last values but will poll the TEC for values. From what I have seen and...
  40. Replies
    4
    Views
    476

    Yes, you can link the fan status or commands to a...

    Yes, you can link the fan status or commands to a fan animation. There is a large library very similar to the one in Insight for animations. The only catch is they can take a bit longer to start if...
  41. Replies
    4
    Views
    476

    I have seen and built very nice graphics with...

    I have seen and built very nice graphics with FINlite. They are not as functional as full blown Insight or other large scale BAS graphics are, but they report data and allow you to change the values....
  42. Replies
    1
    Views
    338

    You should be able to swap the ALN settings, but...

    You should be able to swap the ALN settings, but the panel will coldstart. If it was on the FLN it was acting as a UC most likely. If you have Insight the panel would appear as a TEC with an app...
  43. Replies
    3
    Views
    427

    I have not used Datamate, and at least in our...

    I have not used Datamate, and at least in our branch no one is familiar with it. If there is an Insight machine you can upload the MBC and then do a backup that way. A Siemens person would use Comm...
  44. Siemens has P1 which is their proprietary EIA-485...

    Siemens has P1 which is their proprietary EIA-485 protocol. Most companies use Master devices on the MSTP level, but Siemens TEC controllers can be set up to do Slave as well. A Siemens PXC device...
  45. N2 is not BACnet. I am assuming you are talking...

    N2 is not BACnet. I am assuming you are talking about MSTP. Siemens has controllers that operate on the MSTP level. They can exist on the same wire as other MSTP devices as long as the communication...
  46. Not Dingman, but RENO has to be licensed on the...

    Not Dingman, but RENO has to be licensed on the Insight Server you are using. If it is there is a button on the Main Menu for Remote Notification.
  47. Replies
    13
    Views
    1,558

    PTECs can be loaded and edited using Insight 3.13...

    PTECs can be loaded and edited using Insight 3.13 before that it took a combination of files and a command line tool. They integrated the PPCL stuff into 3.13. I don't think Desigo CC has the...
  48. Replies
    13
    Views
    1,558

    You can use Terminal Emulation to do it. It is...

    You can use Terminal Emulation to do it. It is pain. You can also have Siemens install the webserver in the PXCs. This is free and is what installs the Apogee Editors. You can do everything but...
  49. Replies
    13
    Views
    1,558

    No idea. I do know that whenever I load it up on...

    No idea. I do know that whenever I load it up on my laptop it my RAM usage immediately goes from 2-3 GB to about 12 GB. And it runs like piss on the Core i5 that I have.
  50. Replies
    13
    Views
    1,558

    If it is South America you should have the choice...

    If it is South America you should have the choice of either. Desigo Insight is mostly a European product but can be used in different areas of the world. If it is a new installation you will probably...
Results 1 to 50 of 239