  1. Replies
    4
    Views
    686

    the access panal was too low to get to damper so...

    the access panal was too low to get to damper so i had to take off drive cleat and open elbows side to access to damper to get heat until we replace it
  2. thanks dandyme and pairman, i appriciate it, i...

    thanks dandyme and pairman, i appriciate it, i am waiting to find out if they will do it now which is the best time before this problem kills the ign contr board and gas valve , i do have that...
  3. Replies
    16
    Views
    2,448

    flue heats up gas line to not only pre warm gas ...

    flue heats up gas line to not only pre warm gas , but to evaporate condensate, this hurts to look at, thinking someone could leave it like that is down right scary
  4. American Standard YCD180???? shorted combustion blower

    i found this comb blower running all the time 1.3 amps @230v, tech support said we need to change motor(which i figured) but said a conversion kit needs to be installed as well, from the literature...
  5. Replies
    4
    Views
    686

    I love easy access

    replaced bad blower which someone else found dead. high limit was tripping out , went through system and this is what i found, guess we know what killed blower.
  6. Replies
    1
    Views
    324

    forseen issues or not ???

    i think so, but wanted to know other peoples

    ok carrier 10 ton rtu, fed area which is occupied by two spaces, dont know when they were seperated but were as one at one point. fed both stores but...
  7. Replies
    9
    Views
    680

    i havent heard of them, but, i think the only...

    i havent heard of them, but, i think the only thing that would make it a pos would be the person installing it. just my opinion
  8. Replies
    5
    Views
    527

    strait a/c boss wants them started and checked...

    strait a/c boss wants them started and checked to get paid, i dont add due to i dont want to over charge id rather wait til spring but not my call
    :couchhide:
  9. Replies
    5
    Views
    527

    OAT 43f and puron start ups

    hello new installs and needed to start up, am i too picky or does it not make sense to start up and check correct pressures, or will you be able to get target sc in any temp


    opinions anyone
  10. Replies
    2
    Views
    693

    the units have been serviced each year, im new...

    the units have been serviced each year, im new here i was aked to do check ups and cleanouts when neccessary. i noticed some oil under burner, found oil in blast tube to under blower wheel , nozzle...
  11. Replies
    2
    Views
    693

    av2a-7116 oil pump

    I have my oil license , but rent where im at and he wants me to take care of boiler, i noticed some dripage under burner and found pump at 100psi when running, when shuts off slow burn on flame...
  12. Replies
    6
    Views
    645

    I AGREE FRUECRUE THATS WHY I SAID AFTER BREAKER...

    I AGREE FRUECRUE THATS WHY I SAID AFTER BREAKER AND DISCONNECT FIXED WE WILL BE BACK. BEEN A WEEK AND NO PROBLEMS IT MUST HAVE BEEN BREAKER LIKE I SAID , BUT BOSS IS CONCERNED WHY IN 3 YRS...
  13. Replies
    89
    Views
    6,865

    :couch: SAM ADAMS ? MY FAVORITE CAN I SIGN...

    :couch: SAM ADAMS ? MY FAVORITE CAN I SIGN UP. JUST TOLD BONUS WAS WE HAVE WORK (4DAY WEEKS ) FOR THE NEXT 2 WEEKS. WHICH I AM GREATFUL FOR .
  14. Replies
    89
    Views
    6,865

    :eek2: wow im sure they look forward to that...

    :eek2: wow im sure they look forward to that each year :eek2:
  15. Replies
    9
    Views
    1,408

    when it fails DO NOT TOUCH IT then call...

    when it fails DO NOT TOUCH IT then call someone and let them see it while in the failed state , not after its reset
  16. Replies
    6
    Views
    645

    BREAKER TRIPPING

    no heat call old trane rtu non heat pump with electric heat, disconnect of ,found jumped out, only service switch is cb on first floor. i reset ran to roof, found all 3 banks working and at...
  17. Replies
    9
    Views
    1,320

    ok read page 48 it says it turns on 2nd stage ...

    ok read page 48 it says it turns on 2nd stage if 1st stage can not handle capacity, seems to be working fine
  18. well when whiskey isnt enough its time to bring...

    well when whiskey isnt enough its time to bring in the THE GLUG when made right , and drank at right temp, bottle empties quick, well cheers \_/
    having a few tonight for sure :couch:
  19. Replies
    89
    Views
    6,865

    no christamas party here ever, bottle of choice...

    no christamas party here ever, bottle of choice last year, doesnt look like its happeng this year, looks like only bounus this year is still having a job
  20. Replies
    17
    Views
    1,455

    well this is what my boss tells me to do when...

    well this is what my boss tells me to do when switching from r-22 to 410 make sure lines are not soldered, if so braze them. we do not carry nitro i know issues with c02 but its not my company, i...
  21. Replies
    4
    Views
    467

    NUETRALIZING CARTRIGE

    ok i have been working on and installing some of these 90+ furnaces, first time i ever had to install a nuetralizer which will tie into drain in bathroom. what am i missing how often should this be...
  22. Replies
    30
    Views
    1,873

    I dont like going into home when empmty but oh...

    I dont like going into home when empmty but oh well, its better than having there little dog jump on my leg annoying the the hell out of me where i feel like kicking the bas@#!* and saying shut the...
  23. Replies
    0
    Views
    318

    AMERICAN CARNAGE TOUR

    FINALLY slayer and megadeth together again, cant wait till feb to see them again.
  24. Replies
    0
    Views
    365

    no work again

    damn slow here no work again, :couch: economist say its getting better :eek2: i dont see it
  25. Replies
    5
    Views
    488

    \m/ \m/

    well i have to agree with whec720, there is too many but heres 2 of my favorites

    http://www.youtube.com/watch?v=jgqxQmAbTBc
    http://www.youtube.com/watch?v=b2za92DQOCw
Results 1 to 25 of 40
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event