  1. Replies
    16
    Views
    4,808

    last 10 years and same employer is all i have to...

    last 10 years and same employer is all i have to say about your comment with only 92 posts.

    Good day to you too
  2. Replies
    16
    Views
    4,808

    Frostybeer, there was a restriction in the port...

    Frostybeer, there was a restriction in the port on the cold manifold that i didnt notice because the tubing that was visible was black and the tubing in behind was white so my eye subconciously...
  3. Replies
    16
    Views
    4,808

    Time Builder and City Hvac, boy has this site...

    Time Builder and City Hvac, boy has this site changed. I've been a member almost 7yrs and dont remember attitudes like this. Skipping the real roots and getting ready for retirement eh, no more...
  4. Replies
    16
    Views
    4,808

    Good to see that your at least capable to guide...

    Good to see that your at least capable to guide someone in English grammar on this site.
  5. Replies
    16
    Views
    4,808

    Sounds good gregp. Realized today from tech...

    Sounds good gregp. Realized today from tech support that there is another pressure port hidden in behind pressure switch. Differential pressure of neg. 1.55" is what its looking for. Since that...
  6. Replies
    16
    Views
    4,808

    Why you can't think outside the box JACKASS

    Why you can't think outside the box JACKASS
  7. Replies
    16
    Views
    4,808

    TRANE PRESSURE SWITCH

    TRANE TUX120C960D3. 3 CODE FLASH(PRESSURE SWITCH FAILURE)REMOVED VENTING FROM FURN TO NELIMINATE VENTING PROBLEMS AND MEASURED 0.4"WC NEGATIVE WITH NEW TUBING ATTACHED AND GAS OFF(NO OBSTRUCTIONS...
  8. Replies
    17
    Views
    1,464

    Pneumatics

    I have a building that has an area that is only recieving 12 psi from the main compressor system. The buliding is all drywall. I know i have a leak somewhere. where i have access to check its only...
  9. Replies
    6
    Views
    1,005

    yeah I should, but out of a curiosity of a tech...

    yeah I should, but out of a curiosity of a tech mind do you think something like that would work? & why or why not? I understand the way a ductless uses the lineset, but if you take out the orifice...
  10. Replies
    6
    Views
    1,005

    Slim Condensers, 2 Part Question

    I had an enquiry from a friend about a slim condenser to be installed on a desired side of his home. The problem is the new condensers nowadays gets it too close to his neighbours property line. I...
  11. Thread: 13 Seer

    by chill factor
    Replies
    17
    Views
    1,355

    The propert manager doesnt care about efficiency...

    The propert manager doesnt care about efficiency and doesnt want to replace the air handler. He just wants to give them cooling. If i put in the rated 067 piston will the system still perform...
  12. Thread: 13 Seer

    by chill factor
    Replies
    17
    Views
    1,355

    A Ducane condensor replaced a Carrier condensor. ...

    A Ducane condensor replaced a Carrier condensor. Air handler is still 15 year old Carrier. Original piston is 053. Ducane wants 067 for their condenser. It did not come with piston so i ran it...
  13. Thread: 13 Seer

    by chill factor
    Replies
    17
    Views
    1,355

    13 Seer

    --------------------------------------------------------------------------------

    If you change out an old 10 SEER or less condenser, and keep the original air handling unit & evap, with a 13 SEER...
  14. Thread: 13 Seer

    by chill factor
    Replies
    1
    Views
    577

    13 Seer

    If you change out an old 10 SEER or less condenser, and keep the original air handling unit & evap, with a 13 SEER condensor will it work ok as long as you change the piston to the recommended size...
  15. Replies
    9
    Views
    816

    He didnt know that the system was in electric...

    He didnt know that the system was in electric defrost and thats why the compressor and evap fans were off
  16. Replies
    2
    Views
    418

    What do you guys normally do on a maintenance for...

    What do you guys normally do on a maintenance for these tube heaters that is not to time consumining? Just check condition of tubes, reflectors and see if it fires up?
  17. Replies
    6
    Views
    1,080

    For a Honeywell 7800 flame safeguard, what is the...

    For a Honeywell 7800 flame safeguard, what is the best way to verify if the amplifier is no good. Just a general question, there is no unit that I'm working on.
  18. Replies
    9
    Views
    1,778

    Jogas What happens if you have to do a repair in...

    Jogas
    What happens if you have to do a repair in the hydronics and you need to reset the loop water/air pressures? Or for trouble shooting checks do you always carry a spare sight glass and pop it...
  19. Replies
    24
    Views
    1,601

    You better adjust your manifold pressure to what...

    You better adjust your manifold pressure to what it is rated for if you dont want TSSA up your you know what! Especially with all the problems your unit is giving you, leave that machine to...
  20. Replies
    17
    Views
    1,815

    venting is under 20 feet with 3 elbows and 3"...

    venting is under 20 feet with 3 elbows and 3" pipe.
    In DATA MODE guys, I feel like I have to keep repeating myself, the furnace starts vent mtr at low speed and lights off at low fire. Never gets a...
  21. Replies
    17
    Views
    1,815

    Yes it is a Smart valve. By placing the system...

    Yes it is a Smart valve.
    By placing the system into Data mode(jumping the 24 & data wire at smartvalve) its supposed to go directly to high speed ventor and high fire. Prior to Data mode it is...
  22. Replies
    17
    Views
    1,815

    I installed another 2 of the same furnaces and...

    I installed another 2 of the same furnaces and during set up I did the same thing W1,W2 & R were jumped with power off and then turned power on and right away I got high fire and high speed ventor...
  23. Replies
    0
    Views
    719

    Any of you guys know about Keeprite M#C9MPT100...

    Any of you guys know about Keeprite M#C9MPT100 High Eff.2stage furnaces?
    I jumped W1,W2 & R and alls i get is low fire.
    I removed t/stat wires from fan board and put system into data mode. I...
  24. Replies
    17
    Views
    1,815

    Dude, I wrote i installed a 2 stage stat. I...

    Dude, I wrote i installed a 2 stage stat. I jumped W1 & W2 at the fan board.
  25. Replies
    17
    Views
    1,815

    I recently installed a Keeprite M#C9MPT100 High...

    I recently installed a Keeprite M#C9MPT100 High Eff. 2 stage furnace with 2 stage t/stat. I converted it to propane with the recommended kit.
    My problem is, when i jump R,W1 & W2 together the...