  1. Replies
    317
    Views
    29,951

    I am a Supervisor for a major HVAC contractor in...

    I am a Supervisor for a major HVAC contractor in NYC. It is very hard to find good apprentices. Most of the young guys just starting out want to talk on their phones all day or text their friends....
  2. Replies
    4
    Views
    638

    Thanks. Don't have much hope, Liebert could'nt...

    Thanks. Don't have much hope, Liebert could'nt answer. Seems the BMS has precedence over the unit control panel.
  3. Replies
    4
    Views
    780

    You seem to know about all the companies in NYC....

    You seem to know about all the companies in NYC. Bounce around a lot or have you found a place to stay?
  4. Replies
    4
    Views
    638

    Liebert ICOMM

    Large server room on BACNET. Units won't accept parameter changes. Trying to change Autorestart TD. Any changes made revert back to default. Any ideas?
  5. Replies
    3
    Views
    908

    McQuay ALSD Chiller

    Looked at 3 of these today. Had only one compressor run out of 12. Looked like 3 compressors were not pumping, suct/disch were both the same. Several of them had EXV Alarms, and several of them were...
  6. Your local supply house should have RX11 flush...

    Your local supply house should have RX11 flush kits. They are a little expensive but will help clean your system.
  7. Replies
    18
    Views
    1,401

    15-20 degrees s/h at compressor, higher than 25...

    15-20 degrees s/h at compressor, higher than 25 and you risk overheating compressor motor. All IOM manuals do not specify s/h at compressor, only at the outlet of the evap coil. 15-20 is the best, I...
  8. Replies
    5
    Views
    1,911

    Thats what I'm thinking, PSIO has original...

    Thats what I'm thinking, PSIO has original battery and unit is over 15 years old. I did shut power down to replace some waterside sensors, when I repowered there was no more communications. I already...
  9. Replies
    5
    Views
    1,911

    I have 24volts, all connections are tight. I get...

    I have 24volts, all connections are tight. I get red status blinking, communication green led is blank.
  10. Replies
    146
    Views
    9,664

    I spend 80% of my time following guys on...

    I spend 80% of my time following guys on callbacks. The problem is either over their heads or they just don't care. If my guys get too many callbacks they wind up just doing maintenance 40 hours a...
  11. Replies
    5
    Views
    1,911

    carrier flotronic chiller

    Have a 30HR090E500 chiller, I have a blank display and am not getting comm leds lit up. Status leds are blinking. I believe its the processor module, all fuses good. Any ideas, can't run unit.
  12. Replies
    7
    Views
    2,124

    about 10 degrees subcooling, unit is a split air...

    about 10 degrees subcooling, unit is a split air cooled dx system. Multiaqua puts a TXV on their evaps and you have to supply a condensing unit. Manufacturer states they rate this coil at 250cfm per...
  13. Replies
    7
    Views
    2,124

    multiaqua blues

    Recently installed 5 ton multiaqua dx evap mated to a 5 ton skillaire condensing unit. With unit running we are getting 40# suct/200# disch. 35dt across evap, little to no superheat. Evap only...
  14. Replies
    18
    Views
    2,166

    Subcooling

    Correctamundo, like I said subcooling is only part of your troubleshooting. But it can and does help diagnose a problem. This post can be pages long if we list all the symptoms for...
  15. Replies
    15
    Views
    4,660

    Compressor sweating

    Whats the delta across the barrel? You are looking for a 10 lb pressure drop across the chiller barrel. If you are not moving enough water you will start sweating back to the compressor. 20 degrees...
  16. Replies
    18
    Views
    2,166

    Subcooling

    High subcooling would let you know if you were overcharged. Low subcooling would let you know if you were undercharged. However it depends on the superheat, TD across the evap/cond etc. It can be a...
  17. Replies
    47
    Views
    4,942

    Wine Cellar Problems

    Wine Cellar, refrigeration condensing unit indoor (R22). EMI Ductless split Evaporator section inside wine cellar. Manufacturer calls for 8 degrees superheat. System has a CPR valve, manufacturer...
  18. Thread: UA STAR

    by muchofreeo
    Replies
    24
    Views
    3,038

    Taking it this Saturday, practice test has...

    Taking it this Saturday, practice test has questions on everything. They say only 20% pass this exam. Never took the NATE, did'nt see the point. You get 30 college credits if you pass the Star. Boss...
  19. Replies
    48
    Views
    19,938

    http://www.citymulti.com is the answer to all...

    http://www.citymulti.com is the answer to all your questions.
  20. Replies
    23
    Views
    2,664

    To find out if you damaged the valve, all you...

    To find out if you damaged the valve, all you have to do is remove the powerhead. Flip it over and feel the disc where the threads are. If it can move with your fingers it is NG. If you can't press...
  21. Replies
    19
    Views
    1,509

    TXV, 80-85 suction, 200-225 discharge. I will try...

    TXV, 80-85 suction, 200-225 discharge. I will try lowering the fan speed, the only thing that bothers me is the customer says the unit used to kick a.....
  22. Replies
    19
    Views
    1,509

    Water temp is good, unit has a water regulating...

    Water temp is good, unit has a water regulating valve. I'm thinking restriction as the suction goes into the compressor. Thinking about adding a couple of piercing valves to check pressures in...
  23. Replies
    19
    Views
    1,509

    Water flow is good, strainer is clean. Entering...

    Water flow is good, strainer is clean. Entering air was 79 degrees, supply air was about 69 degrees. Direct drive fan motor running high speed, customer says unit used to run very good. This is a...
  24. Replies
    19
    Views
    1,509

    Was working on a 1/2 ton florida heat pump that...

    Was working on a 1/2 ton florida heat pump that was only putting out 10 degree delta (evap) in cooling. Suction 80-85psig, Discharge 200-225psig.
    This is a water source unit, another technician...
  25. Replies
    32
    Views
    1,842

    Thank you R12 for your reply. My recent reply in...

    Thank you R12 for your reply. My recent reply in this post was targeted to FAT EDDY. I had the audacity to question him in another post. His ego is probably bigger than his waist line. I really do...
Results 1 to 25 of 34