Search Results - HVAC-Talk: Heating, Air & Refrigeration Discussion

Search:

Type: Posts; User: chillerguru

Page 1 of 9 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    0
    Views
    195

    York Maxe chiller

    I have 2 York Centrifugal Maxe with Opti drives, model ykcpcqq4-cfg. one has approx. 11000 hours of operation with 12000 starts, the other chiller has approx. 14000 hours with 9300 starts. I noticed...
  2. Replies
    1
    Views
    267

    Centrifugal impeller repairs

    Anybody know of a outfit that is expierenced in rebuilding, repairing and balancing of centrifugal impellers, Trane impeller if that matters???
  3. Replies
    12
    Views
    2,595

    looking for compressor breakdown and operation of...

    looking for compressor breakdown and operation of capacity control, weather slide valve or piston unloading.
    1) Mcquay chiller M# ALS090AS27-ER10 S#stnu990600101
    Compressor M# ...
  4. Replies
    0
    Views
    258

    Siemans SIMOVERT MASTERDRIVES

    Has anybody encountered a fault on a Siemans drive F026 and if so what was done to correct problem.
  5. Replies
    2
    Views
    726

    Carrier 19XR frame 5

    Has anybody expierenced:
    Alarm 247 DIFFUSER POSITION FAULT. If so please give me details. i did find a few service bulletins with information. what kind of failure have youve seen. is it more...
  6. Replies
    1
    Views
    626

    trane adaptaview on carrier chiller

    anybody installed or worked on an adaptaview upgrade on carrier chillers:gah:
  7. Replies
    1
    Views
    460

    Carrier Commercial Offices

    rumor is Carrier is downsizing and closing some of their Commercial offices. anybody have any insights.
  8. Replies
    1
    Views
    499

    york chiller

    try to figure out tonnage on this york chiller. model) ycws02205c172aamb:gah:
  9. Thread: wye-delta

    by chillerguru
    Replies
    14
    Views
    1,994

    the compressor does not run at all and in wye...

    the compressor does not run at all and in wye configuration, shorting contactor and start contactor are engaged to measure wye amps. this compressor only engages the start contactor , that should not...
  10. Thread: wye-delta

    by chillerguru
    Replies
    14
    Views
    1,994

    wye-delta

    I encountered a wye- delta starter on a Trane aircooled srew chiller (RTAC). When starting up a replacement compressor, chiller has a starter integrity test, that engages start contactor and checks...
  11. Replies
    8
    Views
    1,461

    Absorption Chillers

    I had a question brought up to me. A customer forgot to close purge pump valves, vacuum drain line was open and connected to a 5 gallon bucket of old oil. all 5 gallons of oil were sucked into...
  12. Replies
    153
    Views
    34,192

    Can I get a copy , I have a compressor that...

    Can I get a copy , I have a compressor that shutdown at 30% and wont restart without bleeding oil pressure.
  13. Replies
    8
    Views
    1,912

    york oil filled purge

    Looking for oil filled purge iom for operation and troublshooting
  14. Replies
    4
    Views
    693

    help

    Local york guy said the oil line going toward rotors should be closed at the middle of compressor., was ommitted on style d machine the intention of this line was to cut down on noise levels. looking...
  15. Replies
    4
    Views
    693

    YORK YSDBCBS3-CLAS

    There has been a change in oil filters part number 026-32831-000. the original filter is a pleated element that will produce a total oil filter pressure drop of 12 - 16 psid. The new filter that...
  16. Replies
    5
    Views
    1,178

    Mcquay PEH050(1985) Chiller

    I have a peh 050 that is expierencing oil pump over amping at 7.5 to 8.5 amps, design is 6.2 amps. Tripping on overload after about 5-8 minutes. oil pressure above 120 a130 psig. Any recommendations.
  17. Replies
    1
    Views
    1,517

    York turbopak parts manual

    looking for parts breakdown on this particular manual form 160.43-RP
    (all sections preferred)
    106592
  18. Replies
    5
    Views
    572

    This chiller has a condenser and evaporator in a...

    This chiller has a condenser and evaporator in a unishell configuration.
  19. Replies
    5
    Views
    572

    York chiller

    I would like to see a lubrication diagram. I believe there is a oil cooler in between the oil sump and the oil filter, i just want to be sure. thanks
  20. Replies
    5
    Views
    572

    YORK Y-DTJ-76

    I AM LOOKING FOR LIERATURE ON THIS YORK R-11 MACHINE. I HAVE A LEAK ON A THREADED FITTING ON A OIL LINE. THERE IS A FEW ISOLATION VALVES, HOWEVER MAY HAVE TO BRING IT UP TO 0 PSI. LOOKING FOR IOM FOR...
  21. Replies
    10
    Views
    1,391

    Can

    chillerguru@sbcglobal.net
  22. Replies
    10
    Views
    1,391

    23XL

    CAN PLEASE SEND ME PDF ON TEARDOWN MANUAL.
  23. Replies
    0
    Views
    492

    23xl stop major manual

    i am looking for stop major manual...........sometime ago i had it along with a video and a buddy kept it and lost touch from him. let me know if i someone can give me a copy chillerguru@sbcglobal.net
  24. Replies
    10
    Views
    1,391

    i am looking for stop major...

    i am looking for stop major manual...........sometime ago i had it along with a video and a buddy kept it and lost touch from him. Let me know if i can get a copy. chillerguru@sbcglobal.net
  25. Replies
    14
    Views
    3,981

    23xl teardown

    Anyone have copy of 23 xl stop major manual. I am looking to do rebuild slide valve and inspection of compressor.
Results 1 to 25 of 220
Page 1 of 9 1 2 3 4