Search:

Type: Posts; User: jmandtc

Page 1 of 3 1 2 3

Search: Search took 0.00 seconds.

  1. Replies
    1
    Views
    244

    York 2DEG150N20025STD

    Looking for a wire diagram for york unit. Thanks.
  2. Replies
    15
    Views
    1,119

    Ok...but if heat start and runs in test mode I...

    Ok...but if heat start and runs in test mode I would think the problem would be something related to the intelepak board......but I'm not speaking from experience. Just don't know what to look at a...
  3. Replies
    15
    Views
    1,119

    Trane intelipak

    I found a unit in heat failure. I cycled the heat with no problems.....tried to clear unit using password but would not clear fault.....any suggestions? Thanks.
  4. Replies
    1
    Views
    273

    Trane GAM5AOC60M51SAA SN 13025L4B2V

    My company picked up a new account with a couple of these trane air handlers.....Looking to see if anyone has a manual they can send me. Thanks.
  5. Replies
    8
    Views
    674

    Thank you

    Thank you
  6. Replies
    8
    Views
    674

    Dual capacitor values

    Working on a Amana rcb36b2d. P1223311c compressorc15.3 rla 82 lra fan 1.7 rla Can't read compressor mf values....fan is 5 mf. Anyone know mf for compressor. Thanks.
  7. Replies
    3
    Views
    530

    I updated my profile.......appreciate any info.

    I updated my profile.......appreciate any info.
  8. Replies
    3
    Views
    530

    York split system

    I am working on a york split system. AH model is 3E4180A33A and the condenser is a H1CE150A46C. It is a 2 pipe system, tandem compressors. The unit has problem cooling space in the afternoon........
  9. Replies
    1
    Views
    755

    Carrier RTU Heat pump

    On a Carrier 50HJQO14 600SA S/N 0601F62130 I Noticed a 24volt resettable had tripped on cb4. I did take wires of the loads in the circuit and each time I turned on power the reset would trip. I...
  10. Replies
    9
    Views
    1,301

    Check tubing for blower switch. It may be out of...

    Check tubing for blower switch. It may be out of position and not be able to sense draft of blower motor...
  11. Replies
    2
    Views
    529

    Do you just want the Batteries???

    Do you just want the Batteries???
  12. Replies
    2
    Views
    529

    milwalkee 14.4 volt drill

    I have two batteries, charger, Flashlight( needs bulb), case and a drill that doesn't work for sale. I'm in the Bergen County, NJ area.
  13. Thread: Vacuum Pump

    by jmandtc
    Replies
    13
    Views
    1,118

    I'm interested but my financial situation is not...

    I'm interested but my financial situation is not that good right now.....
    I was hoping for some overtime but nothing is coming my way...Sorry. Jim P.
  14. Thread: Vacuum Pump

    by jmandtc
    Replies
    13
    Views
    1,118

    Vacuum pump

    Have you performed a vacuum test on the pump recently. If so how many microns did it pull down to. Thanks, Jim Peckio
  15. Thread: Vacuum Pump

    by jmandtc
    Replies
    13
    Views
    1,118

    v pump

    Is the pump still available
  16. Thread: Jb Dv-29

    by jmandtc
    Replies
    3
    Views
    1,351

    Jb Dv-29

    I am considering buying the above system to isolate my micron gauge from system. . I especially would like to use it on residential split systems. Any feedback would be appreciated. Thanks.
  17. Replies
    19
    Views
    3,718

    I have the same micron gauge. Can you tell me...

    I have the same micron gauge. Can you tell me your set up. Thanks. Jim
  18. Replies
    14
    Views
    5,107

    Could you tell me the model of the micron guage...

    Could you tell me the model of the micron guage and how much you want for it. Thanks, Jim P.
  19. Replies
    6
    Views
    2,146

    Fluke 902

    Is the meter still for sale???
  20. Replies
    2
    Views
    573

    I recently helped a friend start up a 9000 btu...

    I recently helped a friend start up a 9000 btu no name brand mini split. Put a vacuum on it, then open valves to let refrigerant into system. Due to a mathmatical error I added 1 lb instead of 1...
  21. Thread: Subcool

    by jmandtc
    Replies
    20
    Views
    2,461

    I've just started to do some refrigeration and...

    I've just started to do some refrigeration and was told that you can't check subcooling on a system if there is a reciever. Can I just check subcooling just before the reciever?????
  22. Replies
    1
    Views
    567

    Would anybody have a copy of a luxaire wiring...

    Would anybody have a copy of a luxaire wiring diagram for the DBUCWO72N125DA. I have been running in to alot of them and want to study the diagram at home. Thanks, Jim P.
  23. Replies
    8
    Views
    1,031

    Can anyone recommend a good electronic leak...

    Can anyone recommend a good electronic leak detector. Right now I'm looking at a Richie for around $350.00.
  24. Replies
    6
    Views
    815

    I just bought a pipe clamp temperature probe to...

    I just bought a pipe clamp temperature probe to go with my fluke 16. Is there a right or wrong way to put on liguid or suction line??? Also are there any calibration problems??
  25. Replies
    11
    Views
    4,095

    Can anyone tell me about a web site that carries...

    Can anyone tell me about a web site that carries the ultimate puller. Thanks, Jmandtc.
Results 1 to 25 of 72
Page 1 of 3 1 2 3
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event