    York 2DEG150N20025STD

    Looking for a wire diagram for york unit. Thanks.
  2. Replies
    15
    Views
    1,230

    Ok...but if heat start and runs in test mode I...

    Ok...but if heat start and runs in test mode I would think the problem would be something related to the intelepak board......but I'm not speaking from experience. Just don't know what to look at a...
  3. Replies
    15
    Views
    1,230

    Trane intelipak

    I found a unit in heat failure. I cycled the heat with no problems.....tried to clear unit using password but would not clear fault.....any suggestions? Thanks.
  4. Replies
    1
    Views
    310

    Trane GAM5AOC60M51SAA SN 13025L4B2V

    My company picked up a new account with a couple of these trane air handlers.....Looking to see if anyone has a manual they can send me. Thanks.
  5. Replies
    8
    Views
    740

    Thank you

    Thank you
  6. Replies
    8
    Views
    740

    Dual capacitor values

    Working on a Amana rcb36b2d. P1223311c compressorc15.3 rla 82 lra fan 1.7 rla Can't read compressor mf values....fan is 5 mf. Anyone know mf for compressor. Thanks.
  7. Replies
    3
    Views
    609

    I updated my profile.......appreciate any info.

    I updated my profile.......appreciate any info.
  8. Replies
    3
    Views
    609

    York split system

    I am working on a york split system. AH model is 3E4180A33A and the condenser is a H1CE150A46C. It is a 2 pipe system, tandem compressors. The unit has problem cooling space in the afternoon........
  9. Replies
    1
    Views
    798

    Carrier RTU Heat pump

    On a Carrier 50HJQO14 600SA S/N 0601F62130 I Noticed a 24volt resettable had tripped on cb4. I did take wires of the loads in the circuit and each time I turned on power the reset would trip. I...
  10. Replies
    9
    Views
    1,454

    Check tubing for blower switch. It may be out of...

    Check tubing for blower switch. It may be out of position and not be able to sense draft of blower motor...
  11. Replies
    2
    Views
    540

    Do you just want the Batteries???

    Do you just want the Batteries???
  12. Replies
    2
    Views
    540

    milwalkee 14.4 volt drill

    I have two batteries, charger, Flashlight( needs bulb), case and a drill that doesn't work for sale. I'm in the Bergen County, NJ area.
  13. Thread: Vacuum Pump

    by jmandtc
    Replies
    13
    Views
    1,209

    I'm interested but my financial situation is not...

    I'm interested but my financial situation is not that good right now.....
    I was hoping for some overtime but nothing is coming my way...Sorry. Jim P.
  14. Thread: Vacuum Pump

    by jmandtc
    Replies
    13
    Views
    1,209

    Vacuum pump

    Have you performed a vacuum test on the pump recently. If so how many microns did it pull down to. Thanks, Jim Peckio
  15. Thread: Vacuum Pump

    by jmandtc
    Replies
    13
    Views
    1,209

    v pump

    Is the pump still available
  16. Thread: Jb Dv-29

    by jmandtc
    Replies
    3
    Views
    1,411

    Jb Dv-29

    I am considering buying the above system to isolate my micron gauge from system. . I especially would like to use it on residential split systems. Any feedback would be appreciated. Thanks.
  17. Replies
    19
    Views
    4,019

    I have the same micron gauge. Can you tell me...

    I have the same micron gauge. Can you tell me your set up. Thanks. Jim
  18. Replies
    14
    Views
    5,327

    Could you tell me the model of the micron guage...

    Could you tell me the model of the micron guage and how much you want for it. Thanks, Jim P.
  19. Replies
    6
    Views
    2,251

    Fluke 902

    Is the meter still for sale???
  20. Replies
    2
    Views
    605

    I recently helped a friend start up a 9000 btu...

    I recently helped a friend start up a 9000 btu no name brand mini split. Put a vacuum on it, then open valves to let refrigerant into system. Due to a mathmatical error I added 1 lb instead of 1...
  21. Thread: Subcool

    by jmandtc
    Replies
    20
    Views
    2,615

    I've just started to do some refrigeration and...

    I've just started to do some refrigeration and was told that you can't check subcooling on a system if there is a reciever. Can I just check subcooling just before the reciever?????
  22. Replies
    1
    Views
    611

    Would anybody have a copy of a luxaire wiring...

    Would anybody have a copy of a luxaire wiring diagram for the DBUCWO72N125DA. I have been running in to alot of them and want to study the diagram at home. Thanks, Jim P.
  23. Replies
    8
    Views
    1,067

    Can anyone recommend a good electronic leak...

    Can anyone recommend a good electronic leak detector. Right now I'm looking at a Richie for around $350.00.
  24. Replies
    6
    Views
    833

    I just bought a pipe clamp temperature probe to...

    I just bought a pipe clamp temperature probe to go with my fluke 16. Is there a right or wrong way to put on liguid or suction line??? Also are there any calibration problems??
  25. Replies
    11
    Views
    4,228

    Can anyone tell me about a web site that carries...

    Can anyone tell me about a web site that carries the ultimate puller. Thanks, Jmandtc.
  26. Replies
    11
    Views
    4,228

    Can anyone recommend a good blower wheel, fan...

    Can anyone recommend a good blower wheel, fan blade puller. Thanks, Jmandtc
  27. Replies
    2
    Views
    652

    When installing a transformer is a in line fuse...

    When installing a transformer is a in line fuse put on the load side or the line side.
  28. Replies
    14
    Views
    1,651

    I didn't do anything but put my r22 guages on the...

    I didn't do anything but put my r22 guages on the 410a system. Im embarrassed to tell you I am 410 certified but that was a year ago and this 410 system was not marked. Did I contaminate my guages...
  29. Replies
    14
    Views
    1,651

    I just used my r22 guages on a 410 system. Should...

    I just used my r22 guages on a 410 system. Should I evacuate the lines and maniford???
  30. Replies
    6
    Views
    981

    Can anyone recommend a good ref detector. Right...

    Can anyone recommend a good ref detector. Right now I'm looking a Inficon for around $150. Thanks for your input. jmandtc.
  31. Thread: Liebert

    by jmandtc
    Replies
    20
    Views
    3,111

    I appreciate everyone's help. Apparently the...

    I appreciate everyone's help. Apparently the water doen't have enough minerals in it to operate properly. I know it uses steam to humidfy and we put an Alka selter tablet to get it to work...
  32. Thread: Liebert

    by jmandtc
    Replies
    20
    Views
    3,111

    Can you give me filter name so I can find out...

    Can you give me filter name so I can find out some specs. Thanks.
  33. Thread: Liebert

    by jmandtc
    Replies
    20
    Views
    3,111

    My company has a problem with the supply water to...

    My company has a problem with the supply water to the humidifier having to many minerals. Does anyone have any suggestions.
  34. Thread: Inspector

    by jmandtc
    Replies
    0
    Views
    648

    Has anyone been using "The Inpector" to examine a...

    Has anyone been using "The Inpector" to examine a heat exchanger on a forced hot air system. It's an infared type camera that you snake undeneath. I would appreciate any feedback on it. Thanks,...
  35. Replies
    7
    Views
    1,925

    I was working on carrier unit and came across two...

    I was working on carrier unit and came across two small boards that were in line with the condensor fans of the unit. The electrical diagram showed them as compressor lockout. Do they sense the...