Search:

Type: Posts; User: RACLman

Search: Search took 0.01 seconds.

  1. Thread: Spyder VVT App

    by RACLman
    Replies
    0
    Views
    125

    Spyder VVT App

    Does anyone have a copy of the Spyder VVT App that John Hutchey wrote they would be willing to share?

    TIA
  2. Replies
    2
    Views
    300

    Jace login issue thru web browser

    Has anyone seen this additional login box (please see attached picture) that appears shortly after you complete the normal login to your station thru a web browser. Any way to make it go away?
    ...
  3. Replies
    7
    Views
    433

    I would love one as well. Thanks

    I would love one as well.
    Thanks
  4. Replies
    35
    Views
    2,952

    If it's still available I would like a copy as...

    If it's still available I would like a copy as well.

    TIA
  5. Did this stick come with Lon or BACnet?

    Did this stick come with Lon or BACnet?
  6. Replies
    3
    Views
    313

    No RC-Studio front end at the site but all VAV...

    No RC-Studio front end at the site but all VAV boxes have SSL's with LCD Displays.

    Thanks
  7. Replies
    3
    Views
    313

    Reliable MACH Air Balancing

    Does anyone have any documentation or detailed procedures for performing an air balance on a Reliable Controls MACH Air VAV controller?

    Any help would be greatly appreciated.

    Thanks
  8. Replies
    2
    Views
    342

    nviTodEvent_timeToNextState needs to be set to a...

    nviTodEvent_timeToNextState needs to be set to a value greater than zero.
  9. Thread: SymmetrE

    by RACLman
    Replies
    5
    Views
    374

    When using SymmetrE I have found that you should...

    When using SymmetrE I have found that you should image your machine before making any significant changes. It gives you a fallback position in case of a catastrophe :)
  10. Vykon is the direct sales channel for Tridium.

    Vykon is the direct sales channel for Tridium.
  11. Replies
    4
    Views
    584

    They are Honeywell W7751B XL10 VAV controllers.

    They are Honeywell W7751B XL10 VAV controllers.
  12. Replies
    285
    Views
    47,999

    Controltec, if it's not too much trouble I would...

    Controltec, if it's not too much trouble I would like to get a copy of the manuals as well.
    Thanks
  13. Replies
    23
    Views
    3,196

    If you had the XL10 configuration screen...

    If you had the XL10 configuration screen available in AX then the Wizards are already installed on the JACE. The Commit button only saves the changes to the AX database, you will still have to...
  14. Replies
    23
    Views
    3,196

    If you already have a complete database in AX why...

    If you already have a complete database in AX why would you want to bring Lonspec into the picture. Why not just load the Ax Wizards on the JACE and modify the XL10's
    in your AX database. Seems...
  15. Thread: AX custom tree

    by RACLman
    Replies
    49
    Views
    6,298

    I would like a copy as well if it's not too much...

    I would like a copy as well if it's not too much trouble.

    Thanks
  16. Replies
    9
    Views
    1,000

    As of 2009 when the App was last updated it was...

    As of 2009 when the App was last updated it was not compatible with Rapid Balance. It does have instructions on how to perform the balance proceedure included in the App's documentation.
  17. Thread: ABB LON Drive

    by RACLman
    Replies
    21
    Views
    2,222

    I believe it is found in the snvt nvoStatus and...

    I believe it is found in the snvt nvoStatus and is called manualControl. False = Auto, True = Manual
  18. Thread: JCI PCT VMWARE

    by RACLman
    Replies
    4
    Views
    659

    Just received my e6520 2-weeks ago. The legacy...

    Just received my e6520 2-weeks ago. The legacy port replicator attaches
    to the docking station connector on the bottom of the laptop. has worked
    perfectly so far.
  19. Replies
    3
    Views
    370

    Thanks for the responses. Unfortunately I am...

    Thanks for the responses. Unfortunately I am unable to upgrade the 3.08 LNS database as another contractor is also working on the system as part of a phased upgrade of the controls. The other...
  20. Replies
    3
    Views
    370

    2 versions of LNS on same PC

    Is it possible to run LNS Turbo on a Windows 7 PC with another version of LNS (3.08) running on a virtual Windows XP OS on the same PC?

    Will the two coexist or will they hose each other up?
  21. Replies
    8
    Views
    1,316

    I believe the BACnet Spyders auto adjust thier...

    I believe the BACnet Spyders auto adjust thier baud rate to the JACE when they power up. Cycle the power to the Spyders with the JACE up and online and they should syncronize themselves with the...
  22. Thread: CSI TO AX

    by RACLman
    Replies
    5
    Views
    697

    Ditto on Quicksilvers Driver. Works well.

    Ditto on Quicksilvers Driver. Works well.
  23. Replies
    23
    Views
    4,591

    I also was certified in 06, back then the highest...

    I also was certified in 06, back then the highest score was a 149. Go figure.
  24. Replies
    13
    Views
    950

    Hope everyone has a safe and happy holiday

    Hope everyone has a safe and happy holiday
  25. Replies
    5
    Views
    823

    LonSpec v5.1.5 does support MS Windows Vista and...

    LonSpec v5.1.5 does support MS Windows Vista and is available for download on the Honeywell Buildings Forum website.
  26. The VAV1 or "1000 Series" XL10 VAV controller is...

    The VAV1 or "1000 Series" XL10 VAV controller is not compatible with RapidBalance. The VAV1 pre-dates the use of E-Vision. This controller was programmed and commissioned directly thru the Zone...
  27. Replies
    8
    Views
    3,123

    Honeywell has a Lonworks based package called...

    Honeywell has a Lonworks based package called RapidZone for VVT. It's simple to setup but requires an external dry contact closure for scheduling as the AHU/RTU controller (XL15C) has no real time...
  28. Thread: LON over IP

    by RACLman
    Replies
    24
    Views
    3,103

    That sounds dangerous, sharing anything with EBI...

    That sounds dangerous, sharing anything with EBI is problematic at best. How many lon channels are you dealing with and where does the 600 reside in all this?
  29. Thread: LON over IP

    by RACLman
    Replies
    24
    Views
    3,103

    What version of iLON? 600, 1000, Etc...

    What version of iLON? 600, 1000, Etc...
  30. Verify what version of the PCC-10 driver you are...

    Verify what version of the PCC-10 driver you are using. I have found with running E-Vision in WinXP that you must use this version (pcx10_20Win2k_Ver2.01_B) of the driver and not the latest and...
  31. Replies
    2
    Views
    853

    I'll let you know, I'm going to be trying it in...

    I'll let you know, I'm going to be trying it in the next 2-3 weeks.
  32. Replies
    11
    Views
    774

    Just upgraded 5 WEBS JACE-6's about 2 months ago...

    Just upgraded 5 WEBS JACE-6's about 2 months ago from 3.2.16 to 3.4.43 and they only charged me the single upgrade price on each one.
  33. Thread: AX problem

    by RACLman
    Replies
    5
    Views
    449

    If you are running MS Intellipoint software on...

    If you are running MS Intellipoint software on your machine you may want to
    uninstall it. This has corrected the problem for some who have experienced it.
  34. Replies
    14
    Views
    1,112

    Takes about 15 Minutes and that includes the...

    Takes about 15 Minutes and that includes the on-line licensing.
  35. Replies
    14
    Views
    1,112

    If you must keep the controller you can buy a...

    If you must keep the controller you can buy a copy of XL-Online which will allow a PC to connect to the controller directly, (no graphics but will get the job done). If it's only 1 controller the...
  36. Replies
    6
    Views
    657

    Use CARE with a serial null modem cable and...

    Use CARE with a serial null modem cable and connect directly to the controller, (C-Bus). The original CARE project back-ups will be needed to edit internal parameters in the XFM's or PID's.
    ...
  37. Replies
    5
    Views
    1,704

    Garet, e-mail me your .evb file and I can...

    Garet,

    e-mail me your .evb file and I can generate a list for you.
  38. Replies
    3
    Views
    1,178

    Yes, Both the Honeywell and Distech wizards can...

    Yes, Both the Honeywell and Distech wizards can be used from the web browser.
  39. Re: JACE 600 With Two LON Networks With Spyders?

    Sorry, I should clarify. I have an LPR-10 on the Lon-network to accomodate
    the additional Spyders. As always with this quantity of Spyders you will need
    to run the Spyder tool from your laptop...
  40. Re: JACE 600 With Two LON Networks With Spyders?

    I have a JACE-600-EM with 70 Spyders as well as Modbus and Ndio. all has been operating well for over a year.
  41. Replies
    9
    Views
    2,264

    Spyder VAV K Factor

    Enter the K-factor for your Box exactly- Do not guess. I noticed on an earlier project with 50+ VAV Spyders and Titus VAV Boxes that entering a K-factor that is close will cause wide variances in...
  42. Replies
    35
    Views
    2,464

    The latest version of the Spyder Tool is 2.0.2...

    The latest version of the Spyder Tool is 2.0.2 (for the new SYLK Enhanced controllers). If you are not using these then Spyder Tool 1.18.4 should work just fine. Spyders are slow, just the nature of...
  43. Replies
    3
    Views
    604

    I believe what you want is JCI PN#LP-KIT200-00C

    I believe what you want is JCI PN#LP-KIT200-00C
Results 1 to 43 of 45