  1. I read all the posts. What do you think I meant...

    I read all the posts. What do you think I meant by "make the connections"? Do you seriously think that I was was assuming all he wanted a pro for is to connect tubing? I don't really know how to take...
  2. Timebuilder, he had already addressed post 39...

    Timebuilder, he had already addressed post 39 with post 23.

    He said "ditching the external disconnect was decided by the municipality" and "The installation of a lockable breaker was the solution"...
  3. Replies
    13
    Views
    426

    It does appear you have problems, try this link,...

    It does appear you have problems, try this link,

    http://efficientcomfort.net/asp/ACanalyzer_Web/ACanalyzer_Web.asp

    fill it out and see what it says. It may help.
  4. bzisnky, A link to my website with my contact...

    bzisnky, A link to my website with my contact info is in my sig.
  5. All I can say is that "not knowing what I don't...

    All I can say is that "not knowing what I don't know" has been both my friend and my enemy. Either way I have benefitted in the long run from the experience.

    I do appreciate everyone's concern.
  6. I don't know about that. I can write a decent...

    I don't know about that. I can write a decent contract specifying responsibility. I've consulted and contracted my labor before.
  7. I think the OP is accepting responsibility for...

    I think the OP is accepting responsibility for the project. I think he just wants to hire someone he trusts as a sub to make the connections, and as a consultant to verify the engineering. and so far...
  8. Replies
    13
    Views
    426

    Got it, 0.225"wc TESP. That's reasonable. The...

    Got it, 0.225"wc TESP. That's reasonable. The support tech prolly has no data on fan/coil or AHU coil pressure drops. Was everything else in range? Is anything influencing your suspicion of low air...
  9. Hardest part is running all those line sets. I...

    Hardest part is running all those line sets. I wouldn't to do it by myself but with/or as a helper, it sounds like a good reason to visit Jersey. Besides I actually like an install once in a while.
  10. Replies
    13
    Views
    426

    From your original post, you are actually...

    From your original post, you are actually measuring pressure drop and not TESP. I don't think any manufacturer publishes PD for fan/coil units, only TESP.

    You need to be on the positive side of...
  11. Replies
    13
    Views
    426

    That is one fantastically informative document!...

    That is one fantastically informative document! My gratitude goes out to rundawg for putting that together. The graphics make this the most understandable TESP literature I've ever seen.
  12. I love it when we experiment on our own systems,...

    I love it when we experiment on our own systems, good or bad we always end up learning something.

    Chances are that a 2-3 ton TXV is too big for a 2.5 HP outdoor unit. But maybe not too big. If it...
  13. Replies
    42
    Views
    2,257

    Jim, your onboard barometric sensor is your best...

    Jim, your onboard barometric sensor is your best bet over gps, as altitude conversion is just an estimate. Also the barometer that the weather stations report are calculated to represent sea level so...
  14. Replies
    42
    Views
    2,257

    Jim, I very much understand the reasoning for...

    Jim, I very much understand the reasoning for editing this thread. You're absolutely right about a clever patent attorney using information in the pubic domain against you. I have removed the...
  15. Don't know about glue. Metal reinforcement has...

    Don't know about glue. Metal reinforcement has always done the trick.
  16. Replies
    2
    Views
    179

    You heard wrong, the particles aren't small like...

    You heard wrong, the particles aren't small like asbestos. Our lungs will deal with it like any other dust particles.

    I wouldn't worry about any coming off unless you disturb it. The fact that...
  17. Sounds to me like what we call "oil canning"....

    Sounds to me like what we call "oil canning". Remember those old oil cans you would squeeze to get the oil out? Well no matter... Usually it happens when the blower turns on and (de)pressurizes...
  18. Replies
    12
    Views
    334

    X2 here. Well said golash, If you're in my...

    X2 here. Well said

    golash, If you're in my town in VA, I give no charge second opinions and 5 year parts and labor warranty on all my repairs.
  19. Replies
    4
    Views
    283

    I've used tif's ZX-1 for many years. When the...

    I've used tif's ZX-1 for many years. When the sensor is new it will easily pick up the leak from the H10's reference bottle. Aside from the false positives from disturbing the airflow or banging the...
  20. Replies
    15
    Views
    1,070

    Indoor conditions? dry bulb, wet bulb? Outdoor...

    Indoor conditions? dry bulb, wet bulb?
    Outdoor dry bulb? metering device?

    I'm guessing 80*OD, 78*ID/67 wet bulb with a TXV?

    IF so, then "TXV underfeeding or other restriction downstream of the...
  21. Replies
    42
    Views
    2,257

    I'm fairly certain that the iManifold is...

    I'm fairly certain that the iManifold is estimating the airflow from the readily available evaporator temperature difference chart.

    If the measured temperature split equals the target temperature...
  22. Replies
    1
    Views
    131

    I believe my fees are reasonable. Have you got...

    I believe my fees are reasonable. Have you got the Manual J and S done and documented? or should arbitrary data be used?
  23. He's doing it for his, yours and every other...

    He's doing it for his, yours and every other technicians benefit. If you do obtain the parts yourself, I hope you give him a tip for suggesting/insisting. :)
  24. It's worth every penny to be able to see inside...

    It's worth every penny to be able to see inside those copper lines. Seeing is believing.
  25. Replies
    21
    Views
    781

    Indeed, dedicated return or transfer...

    Indeed, dedicated return or transfer ducts/grilles will make a difference. You can't put more air into a room than you can let out. Some is coming out from under the door but some is also being...