  1. Thread: Trane Rtha 255a

    by absctv
    Replies
    7
    Views
    1,732

    I do not understand ! The RTHA never had a clasic...

    I do not understand ! The RTHA never had a clasic black panel. The CVHE made in the 80's did.
  2. hulk ride

    Trane has the contract for the park and supplied the chellers. I also saw the units but had no camra. Didn't want to bring it on the ride.
  3. Thread: CVHE Dry Run

    by absctv
    Replies
    19
    Views
    2,076

    CVHE Dry Run

    I have alot of overhauls foe the trane co. and enart9591
    is 100% correct . The only chiller that did not transition was the ucp1, so we jumped all the safeties by going from 7 to 9 on mod. 1
  4. Replies
    37
    Views
    4,226

    Bearing Problems VFD's & Fluting

    Did not get the brand name of the problem unit. If it is Trane centravac,then the new bearings will fix it.
  5. Replies
    15
    Views
    2,255

    I HAVE BEEN TESTING FOR OPEN ROTERS ON COAST DOWN...

    I HAVE BEEN TESTING FOR OPEN ROTERS ON COAST DOWN FOR MANY YEARSNOW. GUESS WHAT it workes!!!
  6. Replies
    7
    Views
    1,046

    I fig. you are talking low pressure units. You...

    I fig. you are talking low pressure units. You take half the low and add it to the high. This gives you your net.
  7. Thread: Trane Series

    by absctv
    Replies
    19
    Views
    2,014

    Trane has a policy of less leak spots on a unit!...

    Trane has a policy of less leak spots on a unit! So many times i feel a valve is needed and the answer is less chance of a leak withoiut it. work around it.
  8. Replies
    30
    Views
    3,561

    oilless magnetic bearings

    I cann't help to wonder how they are going to keep the bearing from copper plating?
  9. Thread: LOCTITE-515

    by absctv
    Replies
    22
    Views
    2,706

    I have been overhauling trane chillers for about...

    I have been overhauling trane chillers for about 12 years. I have always used 515 onall oring groves. on the first stage vane flange i smear dow111 on it befor i install it into the suction cover. On...
  10. Replies
    3
    Views
    710

    Trane airhandler

    You need a modle\seral number to get a om manuel.
  11. Replies
    2
    Views
    778

    Sounds like ammonia. A refrig. sample test should...

    Sounds like ammonia. A refrig. sample test should be done.
  12. If you talk with your service rep. he can work...

    If you talk with your service rep. he can work out a service only cotract with you i beleve. What is your location?
  13. Replies
    5
    Views
    1,125

    nailaton

    If I were you I would contact the trane office in Dallas. Thay are by far the best in the area!!!!
  14. Replies
    2
    Views
    1,026

    The cond. unit.

    The cond. unit.
  15. Replies
    2
    Views
    1,026

    I have what i think is a modal number from a...

    I have what i think is a modal number from a whirlpool cond. unit. Does anyone know if i can cross ref. this number NCAFB47(867.817160)
  16. Thread: R-11

    by absctv
    Replies
    6
    Views
    732

    R-11

    You should be in the commercial section with that type refig. !
  17. Replies
    28
    Views
    5,028

    You can find the name plate on control panel...

    You can find the name plate on control panel cover just below the three lights. the model and seral numbers you gave sound right for the unit you dicribed. It is a doubble ender and it comes from the...