  1. Replies
    3
    Views
    1,472

    The change out went well. Put in a new TXV and...

    The change out went well. Put in a new TXV and drier along with it. Note to Geocomfort : Please stop using foam tape . Its a bear to remove. The best route in my opinion the wire wheel attachment...
  2. Replies
    3
    Views
    1,472

    Coil Change out on a GEOCOMFORT today.

    Its going to be a great day today.... Disassemble.

    Always measure that new coil before taking the old one out.
    Hard lesson.
  3. What ever happened to relying on the wiring...

    What ever happened to relying on the wiring diagram and revert to the basics of electricity?? Its amazing how things start to make sense when you just stick to the basics and work your way through...
  4. Replies
    8
    Views
    825

    I saw his other entry after I posted. lol. My...

    I saw his other entry after I posted. lol. My guess is that he has other problems that killed his cap.
  5. Replies
    8
    Views
    825

    Is your Condenser bulging? If its Leaking and you...

    Is your Condenser bulging? If its Leaking and you can hear it than you have some serious issues. Better call your HVAC contact because most likely you have or had some High head press. issues.
  6. Replies
    7
    Views
    1,096

    I would think bringing it back down to ground...

    I would think bringing it back down to ground level to do a comp. change out would be in order.
  7. Replies
    7
    Views
    1,096

    Tall service.

    I love these calls . I know I have to go up there and possibly clean that coil. This Lennox was hung up in an alley. Ended up being just a routine clean & check. 279811
  8. Replies
    14
    Views
    1,185

    Ask yourself if its really worth spending all...

    Ask yourself if its really worth spending all that money on a new A/C system and not get a new indoor coil. It will be clean and no corrosion and provide more efficiantcy. Im sure the steel on your...
  9. Replies
    19
    Views
    3,098

    There has to be a place somewhere on an exterior...

    There has to be a place somewhere on an exterior wall. If you have that many windows your in trouble.
  10. Replies
    11
    Views
    1,076

    Who ever "Topped" off your system needs to look...

    Who ever "Topped" off your system needs to look at his readings again and see what his superheat and subcooling were . There is a reason why your Coil temp. td is so low.
  11. Thread: Freon Leaks

    by luskys a/c
    Replies
    44
    Views
    5,208

    ----- A dirty Condenser can cause a system to...

    -----
    A dirty Condenser can cause a system to leak if it was a 410a system. The high head pressure can climb over 500psi. As mentioned before , the service port will leak.
    --
    The cores can be...
  12. Replies
    4
    Views
    1,544

    I guess some Companies cant afford screws and...

    I guess some Companies cant afford screws and caulk.
  13. Replies
    10
    Views
    1,390

    Had a 3 ton split today kill a dual cap and pop...

    Had a 3 ton split today kill a dual cap and pop the 240v breaker . The coil was not covered what so ever. Everything was on the inside and it was running a 350p head. (r22). Cleaned with coil cleaner...
  14. Thread: Hot Loops

    by luskys a/c
    Replies
    7
    Views
    1,613

    You bet. I have come to find out that we have had...

    You bet. I have come to find out that we have had other problems with this system in the past. Leaking shreader valves , leak in the loop. (I had to charge up the loop when I went on this call couple...
  15. Thread: Hot Loops

    by luskys a/c
    Replies
    7
    Views
    1,613

    One in paticular is a Geo Comfort m#GTC060A11CD ....

    One in paticular is a Geo Comfort m#GTC060A11CD . This is a split system with vertical loops. As far as if my boss installed them correctly I honestly have no doubts in his Craftmanship to detail...
  16. Replies
    10
    Views
    859

    Assuming that your indoor coil and filter are...

    Assuming that your indoor coil and filter are clear and you cleaned the condenser coil good. Even use coil cleaner on that bad boy since it was nasty dirty. I would say a 4*f SH is pretty low and 300...
  17. Thread: Hot Loops

    by luskys a/c
    Replies
    7
    Views
    1,613

    Hot Loops

    We have had several customers who have been turning there stats down to 70* in the 100* heat. The loop temp has gone from a normal 80 - 90* to 110 and then shutting down on high head . Anybody else...
  18. Replies
    10
    Views
    859

    So with a correct charge you will still be able...

    So with a correct charge you will still be able to achieve SC with a dirty Condenser coil. The refrigerant is not going to pick up heat , it just wont saturate into a liquid all the way through the...
  19. Replies
    5
    Views
    694

    Typically no one can predict if a compressor is...

    Typically no one can predict if a compressor is going to die. It happens everyday. There is no need to worry if the tech did something to cause this in his 45 mins there. Keep trust in your Company...
  20. Replies
    10
    Views
    859

    Is it possible to be overcharged enough to have a...

    Is it possible to be overcharged enough to have a high SC but not enough to tripp the HPS or OL? A covered coil will definitely do either but a coil with sediment and dirt in the coil can still give...
  21. Replies
    29
    Views
    2,831

    I carry a police issued night stick in my van....

    I carry a police issued night stick in my van. Picked it up at an auction. Its heavy and can deliver a hit. Never had to use it and the dogs are pretty well mannered @ 90% of the houses I go to. When...
  22. Thread: Attitudes

    by luskys a/c
    Replies
    73
    Views
    4,870

    My drive and intentions have changed dramatically...

    My drive and intentions have changed dramatically over the past 10 years. It has gone from just having a job and a paycheck and heck with all that sense of ownership BS. To being fortunate to have a...
  23. Replies
    32
    Views
    3,950

    Looks like you were in a tight closet. Nice work.

    Looks like you were in a tight closet. Nice work.
  24. Replies
    34
    Views
    3,097

    So, all three service companies use you as a...

    So, all three service companies use you as a service tech and only one of them has you as a full employee? how do you have time to do service work for the other two?
  25. Replies
    34
    Views
    3,309

    This is pretty simple advice but in reality its...

    This is pretty simple advice but in reality its hard to do. I have tried this myself with great and not so great results but the secret is not giving up.

    I dress up like I was getting ready for a...