Search:

Type: Posts; User: gerryboy00

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    18
    Views
    2,745

    i guess that the compressor (that fills up) is...

    i guess that the compressor (that fills up) is not running and that the oil is comming back from the suction line header is that possible?
  2. Replies
    298
    Views
    12,334

    1

    1
  3. Replies
    58
    Views
    9,196

    I am very impress, very good compressor, so far,...

    I am very impress, very good compressor, so far, as I know, one IGV was replaced on a 90 ton compressor......the bad side of the compressor is the procedure for oil replacement....
  4. Replies
    8
    Views
    701

    disconect the LLS and keep the suction pressure...

    disconect the LLS and keep the suction pressure low by starting the compressor manually....check for frost after the valve
  5. hahaha:D and i know exactly where...;)

    hahaha:D and i know exactly where...;)
  6. Y894 Receiver Pressurization Valve Description...

    Y894 Receiver Pressurization Valve
    Description
    The Y894 is a differential pressure regulating valve used on surge
    receiver type systems. It is installed in a line from the discharge of
    the system...
  7. Replies
    22
    Views
    1,490

    huh??

    huh??
  8. Replies
    22
    Views
    1,490

    open

    open
  9. Thread: head master

    by gerryboy00
    Replies
    16
    Views
    1,793

    ??? think? why?

    ??? think? why?
  10. Replies
    25
    Views
    1,712

    what changed in this system ?? the room...

    what changed in this system ?? the room temperature very high load

    you need to install a cpr on the suction line not to overload the unit.....im surprise that the compr. doenst trip on overload!!
  11. Replies
    8
    Views
    1,564

    can u explain ?

    can u explain ?
  12. Replies
    5
    Views
    2,144

    be sure you have a minimum of 20 psig Oil...

    be sure you have a minimum of 20 psig Oil differential check valve on the oil receiver,
    check oils trainers, filters etc
  13. Replies
    9
    Views
    1,328

    i prefer copeland too

    i prefer copeland too
  14. Replies
    3
    Views
    789

    http://www.acmeref.biz/Kpublic/Documents%5Cpen_v46...

    http://www.acmeref.biz/Kpublic/Documents%5Cpen_v46_water_valve.pdf
  15. Replies
    19
    Views
    1,328

    NO

    NO
  16. Replies
    9
    Views
    1,328

    the water-cooled cylinder heads are an option ....

    the water-cooled cylinder heads are an option . now, do the old heads will fit in dunno


    http://www.thermagroup.com/bitzer2.php
  17. Replies
    9
    Views
    1,328

    the replacement is a 4V6.2 ...

    the replacement is a 4V6.2

    http://www.bitzer.de/en/products/index.php?PKEY=K-HH1-V&PTYP=4V-6.2
  18. Replies
    1
    Views
    582

    how about 4 hrs per head 6 X 4hrs= 24 hrs (12...

    how about 4 hrs per head

    6 X 4hrs= 24 hrs (12 pistons)
    8 X 4hrs= 32 hrs (16 pistons)
  19. Replies
    8
    Views
    1,247

    leave the epr on the med.temp circuit adjust it...

    leave the epr on the med.temp circuit adjust it at about 55 psig then adjust the desire set point on the thermostat.

    adjust lpc cut in at 20 psig cut out at 5 psig
  20. Replies
    74
    Views
    3,998

    april 13 8:25 am 8 lbs 4 oz

    april 13
    8:25 am
    8 lbs 4 oz
  21. Replies
    17
    Views
    1,375

    give us some number SuPeRhEaT and sUpErHeAt ...

    give us some number


    SuPeRhEaT and sUpErHeAt :)
  22. Replies
    22
    Views
    3,260

    make sure it is the good valve, and replace it. ...

    make sure it is the good valve, and replace it.
    adjustable valve ?
  23. Replies
    6
    Views
    709

    http://www.yorkupg.com/NewInfo.asp?id=53&t=c&PID=7...

    http://www.yorkupg.com/NewInfo.asp?id=53&t=c&PID=7#Pubs


    under tech guide
  24. Thread: Torch setup

    by gerryboy00
    Replies
    28
    Views
    2,774

    one thing i always used is............

    one thing i always used is............
  25. copy from my manual

    This is the time delay after which the control will attempt to restart the XDC after a loss of power. It
    is programmable from 0.1 to 9.9 minutes in 6-second (0.1 minute) increments. The user can...
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event