Search:

Type: Posts; User: toyo066

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. the original install was good that I can tell....

    the original install was good that I can tell. The unit as in all cases with case coils are like a seperate unit as you know so the case coil and blower were install correctly. I replaced coil due...
  2. Amana Heat Pump with a CASE COIL Air Handler issue

    First of all I have never seen a set up like this. CASE COIL on a Heat pump here in Fla??? I changed out the coil in the air handler due to a leak and the unit is 3 yrs old. I did everything that...
  3. Replies
    69
    Views
    6,692

    I could not watch the whole thing so he did vac...

    I could not watch the whole thing so he did vac it down.... I was like hell no I am not wasting my time watching another seg of this guy trying to act like he knows what the hell he is doing.... If...
  4. Replies
    29
    Views
    3,240

    yes there is a flare and there is a perfectly...

    yes there is a flare and there is a perfectly good piston in it please read the first one where it states that I did take the piston out and flushed the entire system out with nitrogen. I checked...
  5. Replies
    29
    Views
    3,240

    Yeah so am I but its a rental prop and this guy...

    Yeah so am I but its a rental prop and this guy is a real jerk. I mean it is not even that cold out like today it is 68 and he wants his landlord to pay for a stay in the hotel for over night. It...
  6. Replies
    29
    Views
    3,240

    sounds like the reversing valve is working I did...

    sounds like the reversing valve is working I did wack it a few times but it does sound like it is working... Cap tubes I am leaning on that too but right now after going over and over it sounds like...
  7. Replies
    29
    Views
    3,240

    I have to check it out tmw. The liquid pressure...

    I have to check it out tmw. The liquid pressure in this case is 164 going into the system the gas coming out of the ahu drops to 21 at the condenser service valve... So that is why I am saying that...
  8. Replies
    29
    Views
    3,240

    Eco Temp is ICP Carrier product.... CHEAP one.......

    Eco Temp is ICP Carrier product.... CHEAP one.... IT has a TXV Lennox ahu and I changed it out when the condenser was installed. Mechanical device so no braising was needed. Could be bad check...
  9. Replies
    6
    Views
    1,192

    with the information provided cant really help...

    with the information provided cant really help ya. Could be installer did not install correctly... Did you check filter or coil (AHU) to see if they were dirty.... Possible txv issue but I doubt it...
  10. Replies
    29
    Views
    3,240

    yes and this is what I am getting...... I have...

    yes and this is what I am getting...... I have done everything correct... Been in this field for 12 years so all the things that were suppose to be done was done correctly. That is why I also put...
  11. Replies
    69
    Views
    6,692

    omg that is sooooo funny what the hell and he had...

    omg that is sooooo funny what the hell and he had the balls to put this on line. PLEASE I hope that guy is not in jacksonville fla because I think I have seen some of his work before....... toooo...
  12. Replies
    29
    Views
    3,240

    Heating Issue with a Heat pump in heat mode.

    Working on an r22 pos eco temp in cooling mode high side 198 low side 62 its about 75 inside. Switch it to heat mode and the common port drops to 6 psi cap tubes freeze up. 3/4 side goes to 165 and...
  13. Thread: SMAN or Testo?

    by toyo066
    Replies
    147
    Views
    19,024

    aint that the truth.. alot of techs will say that...

    aint that the truth.. alot of techs will say that they know how to do sub cool and superheat and come to findout that they dont.
  14. Thread: New Dremmels

    by toyo066
    Replies
    6
    Views
    1,054

    Youtube

    Dremel
    Multi-Max 2.3-Amp Oscillating Tool Kit the Rotary one sucks. It throws crap into your face this one cuts like butter and you dont have to worry about the spinning of the blade it just...
  15. Replies
    93
    Views
    12,056

    101

    101
  16. Replies
    15
    Views
    1,674

    410a it's a Must

    when using 410a it is the only way to go. if you are short on just one pound of Puron you could lose up to 4 degrees cooling. The only way to get it right is your SC and SH if your having an issue...
  17. Replies
    38
    Views
    4,044

    Not in this Country. You sadly are mistaking sir.

    Not in this Country. You sadly are mistaking sir.
  18. Thread: New Dremmels

    by toyo066
    Replies
    6
    Views
    1,054

    New Dremmels

    Ever run into those Lennox coil leaks on the condenser unit??? The dremmel is the best tool to use to take care of this issue. Cut out some fins and then cut to copper line, insert a piece of 3/8...
  19. Thread: x-13 motors

    by toyo066
    Replies
    0
    Views
    429

    x-13 motors

    Has anyone ever used the x13 surge protectors and if so doesthe surge protector stop these damn things from burning up.... POS I have had about 6 of these things go on me within 3 weeks and there...
  20. Thread: SMAN or Testo?

    by toyo066
    Replies
    147
    Views
    19,024

    Never had an issue I would write Field Piece and...

    Never had an issue I would write Field Piece and tell them and send the SR# they should know when you purchased it. The only issue I had with it was the hanging hook it broke but other then that I...
  21. Thread: SMAN or Testo?

    by toyo066
    Replies
    147
    Views
    19,024

    ditto

    Yeah i am waiting for the 4 to come out soon but I aint jumping to buy it I will wait 6 months. Price will be high.
  22. Thread: SMAN or Testo?

    by toyo066
    Replies
    147
    Views
    19,024

    SMAN 3 VS TESTO

    SMAN 3 IS BETTER HANDS DOWN. I HAVE BOTH OF THEM AND THE WAY THEY BOTH DO THE SUBCOOLING AND SUPERHEAT i HAVE TO GIVE IT TO SMAN 3. PLUS THE TEMP CLIPS ON THE SMAN3 LAST A WHOLE LOT LONGER. THEY...
  23. Replies
    15
    Views
    2,739

    R-22

    I am aware of the EPA statement and what will be done as far as elimination is concerned, what I was getting at is that some SUPER TECH told me that you no longer as of 2014 can do any repairs on the...
  24. Replies
    15
    Views
    2,739

    R-22 EPA REG 2014

    I have been looking to see if this is real or just same old gossip... Come 2014 the EPA is banning R-22. What I have heard is that if a customer has a leak in the system that we are not going to be...
  25. Replies
    39
    Views
    6,028

    I love it and have been using it for about 6...

    I love it and have been using it for about 6 months, good price check out youtube and put in testo 550 and see what some tech's have learned about it... Pretty helpful things.