    is the distributor tubes after the TXV clogged?...

    is the distributor tubes after the TXV clogged? Just a thought?
  2. Replies
    36
    Views
    798

    is the door sealing up. I have seen bad gaskets...

    is the door sealing up. I have seen bad gaskets or door alignment issues cause this in a hot kitchen.
  3. Replies
    7
    Views
    311

    Like I said cool tool. I have all kinds of...

    Like I said cool tool. I have all kinds of expensive tool and might even add this to my pockets. Just making a point for new to the trades of money watchers how to use a small screw driver or the...
  4. Replies
    7
    Views
    311

    cool tool but my pocket screw driver will feel...

    cool tool but my pocket screw driver will feel the magnetic field if the coil is operating.
    Bruce
  5. Thread: Scotsman

    by N2fords
    Replies
    6
    Views
    256

    does it have the black box? I read somewhere the...

    does it have the black box? I read somewhere the new Eyes are only for the new box and doesnt play well with the black box after a month! hope this helps
  6. helioson do you work for Market Equipment or Doc/...

    helioson do you work for Market Equipment or Doc/ I lived many years there and recieved my degree in Spokane community back in 2000.
    Bruce
  7. Replies
    12
    Views
    497

    I have the 116 and the 16 as well good meters

    I have the 116 and the 16 as well good meters
  8. Replies
    12
    Views
    497

    Fluke true RMS I have 3 or four fluke RMS meters...

    Fluke true RMS I have 3 or four fluke RMS meters and love them all . 2 are clamp type. which is i think 324 its my carry around meter! hope this helps
  9. Replies
    5
    Views
    476

    I just use my Ak900 Digicool close off the 1/4...

    I just use my Ak900 Digicool close off the 1/4 turn to the suction side so I can set my input pressure from my nitrogen tank and then let it flow at 1.5 psig allow it to flow through the entire sytem...
  10. Replies
    21
    Views
    1,140

    That was back in the 90's can't remember the amps...

    That was back in the 90's can't remember the amps but temp was over 3000f
  11. Replies
    21
    Views
    1,140

    Carbon electrodes the size of my thighs 5 ft...

    Carbon electrodes the size of my thighs 5 ft long. 3 each of course
  12. Replies
    21
    Views
    1,140

    Worked as a furnace operator melting Cast Iron...

    Worked as a furnace operator melting Cast Iron and 4160 3 phase was our flavor or electricity. powerful stuff. Dangerous yes to the untrained. it was some fun times there in Washington State.
  13. Replies
    10
    Views
    657

    it also matters what type of education or job...

    it also matters what type of education or job experience you had prior to submitting for pro membership. I was I Jet Mechanic who went to Embry Riddle Areonautical Unv. Also an AAS Degree in HVAC/R...
  14. Replies
    10
    Views
    689

    Not trying to start anything but I have had great...

    Not trying to start anything but I have had great luck with Paragon digital and seen many Grasslins fail.Why not just carry the paragons and if power goes out time is always correct on the paragons
  15. Replies
    14
    Views
    1,926

    Do a Google search it is used to keep the...

    Do a Google search it is used to keep the Acetylene stable that's why you keep the bottle upright.
  16. Replies
    14
    Views
    1,926

    the bottle is straight up right? otherwise you...

    the bottle is straight up right? otherwise you could be pulling in acetone!
  17. Replies
    7
    Views
    1,006

    I wish they would of had the kindle when I first...

    I wish they would of had the kindle when I first started this bussiness for about 79 bones you can get one. it will be your bible with all the pdf's you can load for controllers equipment wiring...
  18. Replies
    69
    Views
    2,396

    Said that already many times

    Said that already many times
  19. Replies
    69
    Views
    2,396

    It doesn't..

    It doesn't..
  20. Replies
    69
    Views
    2,396

    If both sides where sucking where is the...

    If both sides where sucking where is the refrigerant
  21. Replies
    69
    Views
    2,396

    Its would still go right past the broke discharge...

    Its would still go right past the broke discharge reed into the high side even if CSP tube was clogged
  22. Replies
    69
    Views
    2,396

    When the discharge valve is bad it won't build up...

    When the discharge valve is bad it won't build up compression but the gas in the system will still be at static pressure for temperature
  23. Replies
    69
    Views
    2,396

    If there is refrigerant in the system it would...

    If there is refrigerant in the system it would read on the high side period. Now if he's not seeing it then it could he is not depressing the Schrader or the ref is gone. If he shuts off the...
  24. Replies
    69
    Views
    2,396

    I am going to let you ponder that thought for a...

    I am going to let you ponder that thought for a while.
  25. Replies
    69
    Views
    2,396

    The refrigerant has to go and be somewhere.

    The refrigerant has to go and be somewhere.
  26. Replies
    69
    Views
    2,396

    No way high side is zero

    No way high side is zero
  27. Replies
    69
    Views
    2,396

    Zero vacuum with a bad pump really

    Zero vacuum with a bad pump really
  28. Replies
    69
    Views
    2,396

    I too enjoyed the video.

    I too enjoyed the video.
  29. Replies
    69
    Views
    2,396

    maybe he has his high side hose on backwards no...

    maybe he has his high side hose on backwards no depressor to push schrader open.
  30. Replies
    69
    Views
    2,396

    Chances are the captube is plugged at the filter...

    Chances are the captube is plugged at the filter drier.
    Did you change the filter drier?
    I cut the cap tube back when i replace the filter drier and always, use nitrogen to enter on the low side to...
  31. Replies
    15
    Views
    655

    Digi cool AK900. They stand up to everyday use....

    Digi cool AK900.
    They stand up to everyday use.
    Very accurate.
    I love mine. They outlast most others out there.
  32. And you think this is a bad idea why? The board...

    And you think this is a bad idea why? The board fuse is still in place. You are just adding it in series with each T-stat wire. I.E. Y, G, W. Etc. This way it will pop that fuse first before the...
  33. you can place a 3 amp fuse on each circuit so you...

    you can place a 3 amp fuse on each circuit so you can see which circuit is causing the issue.. really helps when it is intermitent
  34. Thread: NATE Exam

    by N2fords
    Replies
    30
    Views
    1,857

    Thank you

    Thank you
  35. Replies
    11
    Views
    3,064

    I just bought that From RSD it is well built. I...

    I just bought that From RSD it is well built. I keep mine on the top shelf in the van and I have not used it yet. SOLID BUILD.
    Hope this Helps.
  36. Thread: PSI

    by N2fords
    Replies
    22
    Views
    1,352

    and move all lines around. i had a r-22 that I...

    and move all lines around. i had a r-22 that I could see oil everywhere yet 450 psig and still no leak until I moved a line and heard hisssing ... it was at the compressor on a discharge line factory...
  37. Replies
    56
    Views
    3,181

    also meters are sensitive to battery condition,...

    also meters are sensitive to battery condition, low battery gives false readings.
  38. putty knive to scrape the grease off. towels...

    putty knive to scrape the grease off. towels around the bottom to keep drips from running into the chase for wiring. also a shop vac, degreaser and hot water from a pump sprayer. then remove the fan...
  39. Replies
    8
    Views
    674

    Also check all wiring going to pressure controls....

    Also check all wiring going to pressure controls. Wires rubbing against copper tubing, pinched, or across the blower like carrier did. Inspect all Wires chances are there is a rub through. Also make...
  40. Replies
    42
    Views
    1,902

    had to ask! Alot of times it is overlooked. Glad...

    had to ask! Alot of times it is overlooked. Glad to hear that it was cleaned and checked . Carry on
  41. Replies
    42
    Views
    1,902

    are you sure the compressor valves are not weak....

    are you sure the compressor valves are not weak. you say the box is the problem it might be in the evap txv setting or weak compressors. coils clean you say, did you clean them or they look clean....
  42. Replies
    10
    Views
    679

    mid to upper 90's in Tucson Arizona.

    mid to upper 90's in Tucson Arizona.
  43. Replies
    28
    Views
    2,250

    Make sure the transformer on tranes are grounded...

    Make sure the transformer on tranes are grounded on the common side this will cause issue with Heat side of things seen it before. just saying!
  44. Replies
    18
    Views
    1,620

    does it have a reversing valve on it might be...

    does it have a reversing valve on it might be bleeding past!
  45. Replies
    29
    Views
    1,692

    Make sure the condenser coil is clean might not...

    Make sure the condenser coil is clean might not be rejecting enough heat!
    Can you pump it down and does it hold?
  46. Replies
    9
    Views
    870

    do a u tube search on tearing abart and cleaning...

    do a u tube search on tearing abart and cleaning your old vacuum pump you might be surprised at how well it will work again? congratulations on your new purchase.
  47. Replies
    35
    Views
    2,305

    My low side knob has peeled but still works...

    My low side knob has peeled but still works great...
  48. Replies
    35
    Views
    2,305

    Have had my digi- cool AK900 for over two years...

    Have had my digi- cool AK900 for over two years now and I replaced the velcro Straps for the clamps and love them.
    Highly Recomend them. I also Have 4 other Analog gauges but my go to is always the...
  49. Replies
    24
    Views
    1,745

    It has nothing to do with the manifold leaking it...

    It has nothing to do with the manifold leaking it has to do with the quickness of evacuation using just the hose and the APpion South core remover tool if you are how about course that's that's the...
  50. Replies
    17
    Views
    1,438

    All I use period

    All I use period