Search:

Type: Posts; User: Firebird A/C

Page 1 of 8 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    8
    Views
    378

    I have McQuay fan coil units with that motor in...

    I have McQuay fan coil units with that motor in them. I have ordered from McQuay or had a local motor shop set me up. Phoenix Electric Motors. In Phoenix, AZ
  2. Replies
    10
    Views
    1,107

    WOW..Great photos. Nice work.

    WOW..Great photos. Nice work.
  3. Replies
    7
    Views
    968

    There are no basements or mechanical closets in...

    There are no basements or mechanical closets in the homes out in Phoenix. So the home builders stick everything on the roof. The home builders are moving away from putting equipment on the roof now....
  4. Replies
    7
    Views
    968

    Package heat pump change out

    Installed a new Comfortmaker package 2.5 ton heat pump on the roof. New unit has a new unit stand, new twist elbow, new disconnect and new sealtight with wiring. Old unit was a GE Trane 2.5 ton...
  5. Thread: Superheat

    by Firebird A/C
    Replies
    92
    Views
    3,319

    I would check the manufacture charging specs. For...

    I would check the manufacture charging specs. For superheat most of the time they want you to take suction line temp at compressor or at the suction line entering at condensing unit.
  6. Replies
    6
    Views
    228

    I would not recommend them. They are noisy when...

    I would not recommend them. They are noisy when running. Also I have had a lot of freon leak problems with them. Pay the extra and get a higher end unit. It is worth it in the long run.
  7. Replies
    13
    Views
    1,160

    Where are you located?

    Where are you located?
  8. Sounds like a bad outdoor txv valve which is...

    Sounds like a bad outdoor txv valve which is causing a restriction. Check the outdoor txv sensing bulb cap tube. Cap tube may have lost its charge. Look for crack or rubbed through spot somewhere on...
  9. toyo066....what ended up being the problem????

    toyo066....what ended up being the problem????
  10. Replies
    73
    Views
    7,771

    Learning the trade and working in the field is...

    Learning the trade and working in the field is the easy part. Learning the business side of the trade is the hardest part. Who is going to teach you that? Anyone can go out and run service calls and...
  11. In heating mode can you check the suction...

    In heating mode can you check the suction pressure after the reversing valve???? Meaning is there a suction port between the compressor and the reversing valve? That will help you with telling you...
  12. Replies
    69
    Views
    4,409

    OMG. That is classic stuff. He must of went to...

    OMG. That is classic stuff. He must of went to the Goodman tech school to learn his tricks.
  13. Sounds maybe like the reversing valve is not...

    Sounds maybe like the reversing valve is not shifting all the way over on the heating mode. Does it sound like the reversing valve is switching? Is the common suction port after the reversing valve...
  14. jtrammel is probably right. He is bringing home...

    jtrammel is probably right. He is bringing home around 25k out the 250k. Or is -25k in the hole. Not worth the headache. Go work for someone else and make double or triple that amount. Punch the...
  15. Replies
    73
    Views
    7,771

    At 55 you are to OLD to get into this trade....

    At 55 you are to OLD to get into this trade. Sorry just being honest. This is a young mans trade. Yes there are a few that can do it into there 50`s and 60`s, but not many. At 51, i am usually the...
  16. Replies
    26
    Views
    3,017

    Looks great. Good job.

    Looks great. Good job.
  17. 1. The two party system we have. It is a joke....

    1. The two party system we have. It is a joke.
    2. Organized religion
    3. Corporate lobbyist
  18. I would suggest joining the union. They will have...

    I would suggest joining the union. They will have some more training and classes. Also a lot of knowledgeable people to learn from.
  19. Replies
    1
    Views
    483

    Lennox Gas Furnace wiring diagram

    Anyone have a wiring diagram for this Lennox gas Furnace?
    Model G25MV3-75A-1
    Serial 6395K23363

    Thanks
  20. Replies
    2
    Views
    465

    Is the gas line to the wall furnace ran in copper?

    Is the gas line to the wall furnace ran in copper?
  21. Replies
    9
    Views
    1,057

    Unit is 208-240 single phase. Freon R-22.

    Unit is 208-240 single phase. Freon R-22.
  22. Replies
    9
    Views
    1,057

    Mitsubishi error code E 34? Help

    I have a Mitsubishi mini split heat pump. condenser mod # FDC140HA2 Has an error code of E 34. I have no manual. Anyone know what the code means?
    Thanks
    Mark
  23. Replies
    49
    Views
    1,694

    Is there maybe a bullet drier or strainer filter...

    Is there maybe a bullet drier or strainer filter in the system that you are not seeing?
  24. Replies
    7
    Views
    695

    Hard to swallow, but it is time for a new system....

    Hard to swallow, but it is time for a new system.
    No matter how much perfume you put on a pig it is still a _ _ _
  25. mtrot: Looks like you may be short on return air...

    mtrot: Looks like you may be short on return air to the furnace, or the stamped face return air grilles you have are to restrictive. To get more air going through the existing return grilles you...
Results 1 to 25 of 179
Page 1 of 8 1 2 3 4