  1. At our place, programmers do not get paid pw no...

    At our place, programmers do not get paid pw no matter the circumstance. A lot of installers can make big bucks out in Cali.
  2. Replies
    19
    Views
    625

    The only way that I know of is to get CCT and...

    The only way that I know of is to get CCT and change it in there and download. JCI doesn't seem to care and I've seen sites with 400 VMA's all with the same instance.

    However, if any other...
  3. Replies
    5
    Views
    502

    That's great...

    That's great...
  4. Replies
    12
    Views
    834

    We put them using IP and had issues with the...

    We put them using IP and had issues with the older VLX's. I didn't try to do this over MSTP.. I had a thread on it a few months back..
    ...
  5. Replies
    9
    Views
    706

    Update on this- The 2 BBMD's removed didn't...

    Update on this-

    The 2 BBMD's removed didn't help. Apparently the older VLX's were suseptable to comm problems and the NAE's were pinging them to death with the interlocks, so they would drop out....
  6. Replies
    0
    Views
    210

    ABB Binary COV reporting

    Has anyone ever had issue with the newer ABB Electronic Eclipse bypass not changing binary points over Bacnet?

    I have a hand-auto point mapped and it will not change states unless I delete it and...
  7. Replies
    5
    Views
    424

    Thanks a ton for the info, the doc I have either...

    Thanks a ton for the info, the doc I have either isn't very good, or the 12 hour days are catching up and I missed it. I have a fairly large scan time value because it looks like it is in...
  8. Thread: DanFoss

    by nohelphere
    Replies
    7
    Views
    1,080

    Dan Foss sent out their rep and got it fixed. ...

    Dan Foss sent out their rep and got it fixed. Apparently, version 4.0 was never supposed to be shipped, but we ended up with 8 of them. I guess the patch is 4.0.1. Once mapped- it seems pretty...
  9. Replies
    5
    Views
    424

    Thanks for the help guys- the sensor was...

    Thanks for the help guys- the sensor was configured for a custom table, when all it needed was to be put as platinum. EasyIO is not my strong suite and I was told that startup had already been done....
  10. Replies
    5
    Views
    424

    EASY IO Analog Input filter

    Hello All,

    Has anyone had experience with the temperature reading on an EasyIO controller jumping around like crazy? It's for supply air temp for an AHU and it will jump around 2 degrees instead...
  11. Thread: DanFoss

    by nohelphere
    Replies
    7
    Views
    1,080

    Any luck? The drives I have are supposedly...

    Any luck? The drives I have are supposedly "embedded" Bacnet but I can't discover...
  12. Replies
    2
    Views
    577

    It will work with RAP. Fairly well actually...

    It will work with RAP. Fairly well actually after it has been setup. It has to have an ADs/x though. Graphics won't work on an apple product but anything that will support Silverlight, it will.
  13. Replies
    11
    Views
    799

    If this is possible I would love to hear a...

    If this is possible I would love to hear a solution. It's painful the way it is setup now.

    When we remote desktop in, where are these .xml files kept?
  14. Replies
    9
    Views
    706

    Update.. I've found 2 BBMD devices on the...

    Update.. I've found 2 BBMD devices on the Alerton side. My theory is that the BBMD's are broadcasting everytime I have an interlock that is looking for something. What is strange is that all...
  15. Replies
    9
    Views
    706

    Correct on all accounts I believe. The VLXs seem...

    Correct on all accounts I believe. The VLXs seem to be similar to a JCI NCE. I was talking to the local Alerton rep today and he was saying the older VLXs had issues dropping out if the traffic is...
  16. Replies
    9
    Views
    706

    So, I have all devices that are on the BCMs and...

    So, I have all devices that are on the BCMs and the VLXs mapped. When I put in an interlock, it kills the VLXs only, the BCMs stand loud and proud. All devices have unique id's.

    Next step that I...
  17. Replies
    9
    Views
    706

    Alerton integration into JCI NAE

    Hello all,

    I did a search but couldn't find anything- I may be blind. I've mapped Alerton Bacnet / IP devices into NAE's without issue. However- anytime I try to use an interlock that looks at a...
  18. Replies
    6
    Views
    590

    The Phoenix system will need to be setup to be...

    The Phoenix system will need to be setup to be commandable.
  19. Replies
    15
    Views
    1,599

    Did you reboot the NAE after you enabled the site...

    Did you reboot the NAE after you enabled the site to be a Bacnet network?
  20. Replies
    16
    Views
    2,419

    We had this problem running IE9. If you...

    We had this problem running IE9. If you uninstall the update the GGT graphic will load.
  21. Replies
    3
    Views
    642

    It has to be a BI and it has to be assigned as...

    It has to be a BI and it has to be assigned as accumulator object in cct.
  22. Thread: DanFoss

    by nohelphere
    Replies
    7
    Views
    1,080

    What issues are you having? we are doing an...

    What issues are you having? we are doing an indentical setup- startup will be next month.
  23. Replies
    5
    Views
    665

    What software do you use?

    What software do you use?
  24. Thread: NCE

    by nohelphere
    Replies
    3
    Views
    1,410

    In theory it shouldn't be an issue- however I...

    In theory it shouldn't be an issue- however I would make sure the instance numbers on the trunk are unique. I have had issues with instance numbers being the same on later versions where on the...
  25. Replies
    5
    Views
    665

    Thanks man, I should of just PM'd you- I figured...

    Thanks man, I should of just PM'd you- I figured you had it..