  1. Replies
    5
    Views
    365

    We have EBI R410 and we can retrieve any...

    We have EBI R410 and we can retrieve any historical data that we need. We import the data into Microsoft Excel where we can view the spreadsheet that shows the hourly value (or whatever period we...
  2. Replies
    8
    Views
    680

    Control Geek, can you tell me what DCV is? Thanks

    Control Geek, can you tell me what DCV is? Thanks
  3. Replies
    1
    Views
    421

    If it is a failure in one of the cabinets, it is...

    If it is a failure in one of the cabinets, it is a device in the field that has failed or lost power. If it is the complete cabinet, you have lost communications to that cabinet, again it may have...
  4. Thread: SymmetrE

    by rody
    Replies
    5
    Views
    316

    I maintain a Honeywell EBI System which I...

    I maintain a Honeywell EBI System which I understand is the same as SymmetrE. It is correct in saying the SymmetrE is the supervisor and all the points are in the controllers. In EBI we have a...
  5. still using a windows 98 laptop need to upgrade

    I service honeywell microcels for my employer using an old dell latitude cp with win 98. Does anyone know if I can get a windows 7 machine to work with VMware installed and have it boot to windows 98...
  6. Replies
    3
    Views
    2,106

    It is probably available on the Honeywell...

    It is probably available on the Honeywell Environmental and Combustion Controls web site. You can search by document number. (https://customer.honeywell.com/Business/Cultures/en-US/Default.htm) I...
  7. Replies
    1
    Views
    405

    I am very interested in in the modules. Please...

    I am very interested in in the modules. Please check my profile and shoot me an e-mail. Thank you.
  8. Replies
    5
    Views
    746

    We had EBI r310 for about seven years with a...

    We had EBI r310 for about seven years with a single server. The server also acted as the only operator work station. We use it for HVAC control only, no access control, no fire system. We have a...
  9. Replies
    8
    Views
    950

    The file will have an extiension of .pjt If you...

    The file will have an extiension of .pjt If you look at files through windows explorer and see something like "ABC_C004.pjt" that will tell you it is a care backup file and if the original person...
  10. Replies
    12
    Views
    1,777

    We have the Honeywell EBI system which is...

    We have the Honeywell EBI system which is basically the same as Symmetre but used for HVAC and installed by the branches only. We have the exact same problem. The current value on the graphic and...
  11. Replies
    1
    Views
    648

    upgrading EBI from R310 to R410

    Be prepared for some rambling. We have a large facility running EBI R310 on Windows XP with a 10,000 point license, one server that also acts as the operator work station and a laptop to use as a...
  12. Thread: Honeywell Advice

    by rody
    Replies
    3
    Views
    589

    Are there constant volume VAV boxes at the...

    Are there constant volume VAV boxes at the reheats for each room or is it just the reheat coil in ductwork with no room air cfm control. If there is no VAV damper an easy way to do it might be with...
  13. Returns in the outside walls, supplies in the interior walls. Is this OK?

    My daughter bought a single level ranch house with full basement, in New England. The furnace and all ductwork is all in the basement. Furnace was replaced and an a coil added some years ago. The...
  14. Replies
    4
    Views
    732

    CARE software is proprietary. If you did have the...

    CARE software is proprietary. If you did have the software you would also need the project backup file to be able to re-assign the input to a different terminal. That file would have a name that...
  15. Replies
    2
    Views
    934

    honeywell EBI Log Viewer

    Anyone have any experience with Honeywell's Log Viewer in EBI? I've attached a snapshot of about six hours, but the whole log is can be huge in just a day. Our EBI server is also our only station. We...
  16. Replies
    18
    Views
    2,081

    Question, when you refer to Honeywell legacy...

    Question, when you refer to Honeywell legacy panels, do you mean the XL Plus (R7044), or the newer XL5000 to XL8000 systems. I maintain the Honeywell control systems in a very large hospital campus...
  17. Thread: Honeywell System

    by rody
    Replies
    4
    Views
    720

    There are two ways to access the data in a R7044...

    There are two ways to access the data in a R7044 controller. Both through the POT port at the bottom front of the board. The easiest is with the POT (portable operators terminal) where you can...
  18. EBI server backup best practices advice needed

    We have an EBI R310.1 system (HVAC only with 10,000 licensed points) that was supposed to be set up with a server PC located in our data center and a separate operator workstation PC located in the...
  19. Replies
    9
    Views
    1,055

    I'm not sure of your question but I've worked on...

    I'm not sure of your question but I've worked on many projects where we have had many types of XL10 controllers on the same communication bus and in the same project. You can place a smart VAV...
  20. Replies
    2
    Views
    625

    I worked for Hwell for ten years. I thought that...

    I worked for Hwell for ten years. I thought that XBS did not support Delta 1000 controllers, only XBSi did. I have worked on a few XBS systems and thought that XBS was for XL5000 controllers only.Are...
  21. Replies
    11
    Views
    1,001

    New England 100% outside air units

    On 100% outside air AHUs we always had a 1/3 and 2/3 steam valve to the coil. Now our in house engineering dept. is trying to save money and specifying only 1 steam valve, with a minimum position...
  22. Replies
    7
    Views
    1,335

    W7751H

    I see you're all set but I was wondering, are you using e-vision, lonworks or something else?
  23. Replies
    10
    Views
    1,132

    1. Hey, I AM the customer, and a controls tech...

    1. Hey, I AM the customer, and a controls tech (install and service)
    for the last fifteen years.
    2. By the "big three" I was referring to JC, HW, and Seim. I worked for one of
    them...
  24. Replies
    10
    Views
    1,132

    We got 'em by the short hairs.

    It may be hard to interpret hearing only one half of the conversation, but on its face it sounds like; "Once our product is in their facility, we'll have them at our mercy for service, upgrades etc....
  25. Replies
    6
    Views
    500

    The other buildings in the complex are C BUS on...

    The other buildings in the complex are C BUS on BNAs. This new project is in a separate bldng, I don't know if they will use lon or C bus.
    I was under the impression that XL 100 was being phased...