  1. Thread: Wall Mount

    by HPpro
    Replies
    2
    Views
    1,018

    I saw it driving down the road had to stop and...

    I saw it driving down the road had to stop and get a pic. The house is sitting empty, it's a foreclosure .
  2. Replies
    27
    Views
    5,095

    It was really hard to tell, EVERYTHING was burnt....

    It was really hard to tell, EVERYTHING was burnt. The indoor filter was a spaceguard 2200 under the air hander, it hadnt been changed in a few years and was PLUGGED! It happened on a warmer evening...
  3. Thread: Wall Mount

    by HPpro
    Replies
    2
    Views
    1,018

    Wall Mount

    Judging by the way the grass looked I dont think the lawn guys did this

    http://img84.imageshack.us/img84/8530/10110615431.jpg

    http://img155.imageshack.us/img155/284/10110615441.jpg
    ...
  4. Replies
    27
    Views
    5,095

    Its hard to stop a Trane.

    Found this a few months back, it was right at the end of the heating season. Customer called and said he had a little problem with his outdoor unit, I walked around the corner and saw that i had to...
  5. Replies
    16
    Views
    2,790

    Surprised the tank isnt leaking on that thing...

    Surprised the tank isnt leaking on that thing yet. Does Lennox still give customers a credit on new equipment if the tank fails on those?
  6. Replies
    16
    Views
    1,355

    What exactly is shutting down? Im guessing from...

    What exactly is shutting down? Im guessing from what your saying its just the compressor? Is there a TXV on the indoor unit, maybe its a possibility on a long run cycle your super heat is rising...
  7. Replies
    10
    Views
    942

    Light heat is key!

    Light heat is key!
  8. Replies
    40
    Views
    7,700

    Thats just sorry worksman ship. The grass will...

    Thats just sorry worksman ship. The grass will be greener on the other side for sure in this case. The worst thing about that is you get put in the situation where eventually some customers are...
  9. Replies
    13
    Views
    4,004

    Wow, that looks horrible. Who would run screws...

    Wow, that looks horrible. Who would run screws into someones window frame? I guess "They thought it looked better" if they ran the condensate line in one direction and the lineset in the other.
  10. Could you try unhooking the electric heat just to...

    Could you try unhooking the electric heat just to eliminate that as a possibility?
  11. Thread: variable speed

    by HPpro
    Replies
    3
    Views
    556

    Usually the modules on the motors fail, and its a...

    Usually the modules on the motors fail, and its a lot less to replace just the module. Pick up a tester for the motors, they hook to 24 volts and to the motor and it will allow you to test the...
  12. Thread: Install manual

    by HPpro
    Replies
    14
    Views
    2,088

    Thats the "weed eater protection kit" those are...

    Thats the "weed eater protection kit" those are extra on installs!
  13. Replies
    17
    Views
    1,523

    Ive never had any problems with a 410 system that...

    Ive never had any problems with a 410 system that you couldnt have with a R22 system. Been installing and servicing them since they first became available.
  14. Replies
    14
    Views
    1,392

    Dont think i ever heard a motor sitting idle...

    Dont think i ever heard a motor sitting idle humming, did you try unhooking the motor leads just to make sure that was indeed making the noise?
  15. Replies
    7
    Views
    1,324

    lol, was there any on the threads??

    lol, was there any on the threads??
  16. Thread: Cheap landlord

    by HPpro
    Replies
    7
    Views
    2,045

    Ha! Looks like it just slides right on out!

    Ha! Looks like it just slides right on out!
  17. Thread: Bad compressor?

    by HPpro
    Replies
    13
    Views
    1,584

    Sounds like it, toggle between modes (Heating &...

    Sounds like it, toggle between modes (Heating & Cooling) and see if you can hear your reversing valve move
  18. Thread: wiring question

    by HPpro
    Replies
    18
    Views
    1,374

    Ok so on a gas furnace the board is controling...

    Ok so on a gas furnace the board is controling the blower. Dependent on which stage its in. Agreed? Thats all I stated. The control controls the blower, the original question asked about jumping...
  19. Thread: wiring question

    by HPpro
    Replies
    18
    Views
    1,374

    Yes you do have to tell the control board the...

    Yes you do have to tell the control board the stages of the thermostat, even if you have a 2 stage thermostat the control board still controls the blower in the heating mode. You also have to tell...
  20. Replies
    106
    Views
    7,046

    I think he meant hydronic coil in the air...

    I think he meant hydronic coil in the air handler. (hot water forced air heating) you said earlier it was a "hydro" unit. If that coil is impacted in any way that could effect air flow across the...
  21. Replies
    106
    Views
    7,046

    Refrigerant returning on the suction line cools...

    Refrigerant returning on the suction line cools the compressor, if you starving your evaporator your not returning the proper volume of vapor refrigerant and that will over heat a compressor and at...
  22. Replies
    106
    Views
    7,046

    is the compressor running when you have those...

    is the compressor running when you have those readings? If so those arent stabilzed pressures, that is your pressure differential your running compressor is creating. If you took super heat and sub...
  23. Thread: wiring question

    by HPpro
    Replies
    18
    Views
    1,374

    they ask for O as well so the AHU will know to go...

    they ask for O as well so the AHU will know to go the set cooling speed, not the set heating speed when the AHU is used on a cooling only installation.
  24. Replies
    34
    Views
    1,674

    I had to read it a few times but thats what i got...

    I had to read it a few times but thats what i got out of it. The question was "ever have this happen" and the rest was describing the scenario. I guess the guage sealed to the suction line port and...
  25. Replies
    30
    Views
    2,996

    Out of all three of those being at the same price...

    Out of all three of those being at the same price I would have to take the american standard. My personal opinion. They have some nice equipment in various product lines.