Search:

Type: Posts; User: dapper

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    2
    Views
    152

    Mitsubishi M-NET

    Mitsubishi' spec calls for the M-NET cable to be 'Shielded Cable Type CVVS or CPEVS'. These seem to be Asian standards.
    Is this just standard 16 ga. shielded wire or is there something special...
  2. Thread: KEP MINItrol

    by dapper
    Replies
    4
    Views
    133

    joey, thanks for the link. That is one of the...

    joey, thanks for the link. That is one of the documents that I have already but I think it may be only for RS232 interface and not the MODBUS interface. In each case they use a DB9 connector with a...
  3. Thread: KEP MINItrol

    by dapper
    Replies
    4
    Views
    133

    joey, I have tried HyperTerminal and Putty. No, I...

    joey, I have tried HyperTerminal and Putty. No, I have not used 2 stop bits. The documentation that I have says 1 stop bit.
    Do you have the manual in pdf? Can you send it to me?
  4. Thread: KEP MINItrol

    by dapper
    Replies
    4
    Views
    133

    KEP MINItrol

    Anyone have any experience with a KEP MINItrol Ratemeter & Totalizer? I have one with a MODBUS RTU interface that I am unable to communicate with. I sent it back to the factory
    once and they said...
  5. Replies
    17
    Views
    976

    Ditto the KMC FlexStat

    Ditto the KMC FlexStat
  6. Replies
    0
    Views
    111

    Istec water meter and display

    Anyone have experience with an Istec series 1800 water meter with a Model 9305 display with Modbus interface?
    I'm having some issues configuring the interface as it defaults to 300 baud. There...
  7. Thread: 3D Floorplans

    by dapper
    Replies
    13
    Views
    1,014

    Nice work mechdorn!

    Nice work mechdorn!
  8. Thread: best lap top

    by dapper
    Replies
    30
    Views
    1,116

    In my opinion memory and speed are not that...

    In my opinion memory and speed are not that important with most control systems. Most controls system interfaces are very slow to start with. if you plan on creating your own 3d floor plans etc. on...
  9. Replies
    32
    Views
    1,378

    controldude might be on to something with the...

    controldude might be on to something with the theory of the wall mass. Try to get your hands on an infrared thermometer and check the wall temperature when your cooling system is running wild like...
  10. Thread: BabelBuster...

    by dapper
    Replies
    1
    Views
    256

    BabelBuster...

    Any experiences, good or bad, installing a BabelBuster 485 Lonworks to Modbus RTU on a Tridium Lon network?
  11. Replies
    19
    Views
    419

    I hope I didn't miss something here but there are...

    I hope I didn't miss something here but there are 2 different free programmable plugins. There is the old version and the GFX version. I don't believe the GFX version will work with the EC8A even...
  12. Thread: WSHP DP switch

    by dapper
    Replies
    14
    Views
    453

    Matt, I've installed thousands of water source...

    Matt, I've installed thousands of water source heat pumps over the years and never saw a spec. or a manufacturers recommendation to install diff. pressure switches across the condenser coils. The...
  13. Thread: WSHP DP switch

    by dapper
    Replies
    14
    Views
    453

    Another engineer that has no clue what they their...

    Another engineer that has no clue what they their spec says
  14. Thread: BBMD vs VPN

    by dapper
    Replies
    25
    Views
    2,066

    Landmine, not for nothing but your username and...

    Landmine, not for nothing but your username and avatar make me a little 'queasy'. I mean no disrespect if this is something that you have gone through but if this is meant to be funny, I'm having a...
  15. Replies
    3
    Views
    334

    Ok, just searched my old posts. It was Digo that...

    Ok, just searched my old posts. It was Digo that straightened me out. If you are doing this remotely you have to open the Fox port on your network. The two ports that need to be open on your...
  16. Replies
    3
    Views
    334

    If it kicks you right back to the login screen...

    If it kicks you right back to the login screen then I think you are missing a module on the Jace, or you have a license issue. Is the webui licensed? I've had this problem before but don't remember...
  17. Replies
    0
    Views
    121

    Trane WSHP with wireless t'stats

    Have a job with Trane WSHPs with Trane wireless t'stats. I've noticed lately that you cannot turn off the fan or turn the unit off through the t'stat. Set the mode to OFF and the unit continues to...
  18. Replies
    26
    Views
    2,076

    Thanks guys, I'll look into the Max Line driver. ...

    Thanks guys, I'll look into the Max Line driver. I can work with the N2 devices. I don't get a lot of exposure but I took the DX class many years and still remember the basics. I've already...
  19. Replies
    26
    Views
    2,076

    Dredging up this old thread with some notable old...

    Dredging up this old thread with some notable old friends.
    I recently got involved with a building that has 3 N30s, 5 dx-9100s and 20 or so VMAs. The previous contractor 'took' the M-3 front-end...
  20. Thread: N30 User Manual

    by dapper
    Replies
    6
    Views
    229

    Got Project Builder, thanks.

    Got Project Builder, thanks.
  21. Thread: N30 User Manual

    by dapper
    Replies
    6
    Views
    229

    Have that one already, thanks.

    Have that one already, thanks.
  22. Thread: N30 User Manual

    by dapper
    Replies
    6
    Views
    229

    N30 User Manual

    Anyone have a current copy of the N30 User Manual. I have a 2001 version but would like something more current. There seems to be a problem with the online source.

    Thanks in advance
  23. Replies
    25
    Views
    1,993

    ruchc30, I went ahead and reloaded the 3 patch...

    ruchc30, I went ahead and reloaded the 3 patch files just to be sure there wasn't an issue there. I overwrote the wbapplet.jar. The baja.jar and fox.jar were the same. I cleared all of the caches...
  24. Replies
    25
    Views
    1,993

    mechmike, I tried that after posting the last...

    mechmike, I tried that after posting the last post. I logged on just fine with IE and Firefox after that the first time, but subsequent times there was no data. 'Config > Drivers' tree will not open....
  25. Replies
    25
    Views
    1,993

    Ok, I've spent some time and logged in using the...

    Ok, I've spent some time and logged in using the restricted User credentials with Workbench and have no issue. I can simultaneously log in with another PC with either Firefox or IE and I get no...