  1. Replies
    2
    Views
    332

    I think that's what I'm looking for. Thank you!

    I think that's what I'm looking for. Thank you!
  2. Replies
    2
    Views
    332

    Fieldpiece adapter/connector

    Anyone know a link to where I can buy an adapter to connect my Fluke test leads to my Fieldpiece meter? Looking at a Fluke lead - it's a female connector, but my Fieldpiece lead has a male plug. I'd...
  3. Replies
    52
    Views
    4,758

    Use new gas too.

    Use new gas too.
  4. Replies
    52
    Views
    4,758

    Yea, given that none of them are drafting, ur...

    Yea, given that none of them are drafting, ur probably right. I'd change the liq drier too.
    Good luck!
  5. Sounds like an interesting experiment! A 30k btu...

    Sounds like an interesting experiment! A 30k btu coil is a 30k btu coil! With the correct txv on a high temp system (12k btu/ton), it should work. Give it a shot with one! I'll bet it'll go off...
  6. Replies
    52
    Views
    4,758

    Assuming your head psi is good when you're...

    Assuming your head psi is good when you're onsite. This might be a dumb question, but are there any new OFM's? Good ol' Aaon requires OEM motors! The aftermarket motors ratings may match up but will...
  7. Replies
    0
    Views
    281

    Varitrane VPEF Reheat Problem

    I have a VPEF1200 stand alone that was calling for first stage heat upon call for cooling. Initially, I thought it was turning on to prevent overshooting the set point. But it wasn't kicking out even...
  8. Replies
    16
    Views
    7,247

    Print that IOM and call the Fulton rep while your...

    Print that IOM and call the Fulton rep while your on it. They're pretty helpful, OTT everytime I called they sound like they smoked 200 cigarettes and drank 2 pots a coffe that morning.
  9. Replies
    16
    Views
    7,247

    Sorry to get back so late. The nut on the front...

    Sorry to get back so late. The nut on the front of the flapper assembly is your air intake adjustment. I can't remember the setting for it, but you can download the IOM from Fulton's website and then...
  10. Replies
    16
    Views
    7,247

    Also, have you checked the air intake flapper for...

    Also, have you checked the air intake flapper for clogs? Those rings get clogged pretty often too. Or it'll vibrate itself closed.
  11. Replies
    16
    Views
    7,247

    I'm sure you've already checked, but have you...

    I'm sure you've already checked, but have you checked the gv vent line for clogs? I use to work on a lot fulton's in virginia beach and (i forgot the name of them) bugs would nest inside the vent...
  12. Replies
    20
    Views
    2,217

    I ran across this a couple times. The problem is,...

    I ran across this a couple times. The problem is, Waco is too lazy to update the literature after the conversion from air to water.

    Can you use the air version? It should be fairly similar. The...
  13. Replies
    23
    Views
    1,788

    When I interview for a job, I warn my future...

    When I interview for a job, I warn my future employer that I will not lie to my customer. That's definetly a double-edged sword as we all have made mistakes, but do you tell the customer you...
  14. Replies
    31
    Views
    5,432

    If I see any with your initials on it in my area,...

    If I see any with your initials on it in my area, I'll let you know.
  15. I weigh it in at manufacturers recomendations...

    I weigh it in at manufacturers recomendations everytime, if I can! Of course, if I'm adding a 30 cu in drier it could take up to an extra pound, but I start with the manufacturers recommendations...
  16. Replies
    136
    Views
    22,176

    BTW, How do you like the micron gauge? I've tried...

    BTW, How do you like the micron gauge? I've tried several and the only one I've ever had that's worth a crap is the Robinair 14010a. (at 500 bucks!)
  17. Replies
    136
    Views
    22,176

    who cares if 1/2" hose are overkill?! Better that...

    who cares if 1/2" hose are overkill?! Better that you get it right the first time, than have to blow the gas (i mean recover) and redo it!
  18. Replies
    12
    Views
    1,722

    John, there's a thread on here with someone who...

    John, there's a thread on here with someone who has had the same problem. attached is the link to it.

    http://hvac-talk.com/vbb/showthread.php?t=335422&highlight=liebert+short+cycle+alarm
  19. Replies
    15
    Views
    1,683

    Yea, they did! FLA was 2.0 however i was pulling...

    Yea, they did! FLA was 2.0 however i was pulling 2.2. I noticed the motor was also considerably larger (depth) than the A/M's. I figured it must be more run windings. Also, I noticed it was open-type...
  20. Replies
    14
    Views
    2,647

    Using the PT Chart

    The first thing I'd do is verify the sensing bulb is clean, placed correctly on the suction line, and that it's responding correctly <--(when dryer is operating). I'd do this by removing it, sanding...
  21. Replies
    15
    Views
    1,683

    For anyone still interested, replaced the motors...

    For anyone still interested, replaced the motors with OEM and that has fixed my problem. Thanks everyone for all of your inputs!!
  22. Replies
    9
    Views
    1,140

    I've been there!!

    LOL!!!
  23. Replies
    9
    Views
    1,140

    Considering you've meggered the motor and have...

    Considering you've meggered the motor and have good resistance and I'm sure you've already traced all your wiring for shorts, could humidity be building up inside your junction boxes or disconnect....
  24. Replies
    1
    Views
    1,492

    Grainger is a Greenheck distributor. Good luck...

    Grainger is a Greenheck distributor. Good luck with them, though!
  25. Replies
    8
    Views
    1,646

    I'm not a steam guru by any means but Boiler...

    I'm not a steam guru by any means but Boiler Operator's Workbooks would probably be more helpful to you since you already have a strong background. Workbooks, really hit on the safety settings and...