  1. Replies
    18
    Views
    5,158

    The only reason I can think of it the didn't...

    The only reason I can think of it the didn't install the same size heat banks. All the data I have seen is about the same as most of the older ones.
  2. Replies
    18
    Views
    5,158

    I would agree.

    I would agree.
  3. Replies
    22
    Views
    2,872

    It depends where in MO they live. Around here,...

    It depends where in MO they live. Around here, there are no permits or inspections.
  4. Replies
    11
    Views
    3,466

    What????? Who the H**l are you?????

    What????? Who the H**l are you?????
  5. Replies
    11
    Views
    3,466

    Not cooling enough

    This customer bought this lake house last year and had another company come out and removed the leaking liquid line service valve, installed a secound LL drier,(don't know if he didn't see the one...
  6. You need to remove the pricing from your post as...

    You need to remove the pricing from your post as it is not allowed here. You need to read the rules.

    No one here can tell you what it would cost as different areas charge different prices, like my...
  7. I am showing a replacement coil is avalible for...

    I am showing a replacement coil is avalible for that airhandler.
  8. Replies
    10
    Views
    673

    It does not matter if you install on the supply...

    It does not matter if you install on the supply or return. You will still get the higher pressure supply air going through the humidifier and into the return.
  9. Replies
    2
    Views
    702

    You need to have a Pro wire a fan powered...

    You need to have a Pro wire a fan powered humidifier, you can not hook the straight to the board. You will short some thing out.
  10. Replies
    9
    Views
    562

    Unless something has changed in the last couple...

    Unless something has changed in the last couple of years, Carrier requires 2 deep traps on there airhandlers as they have a very high negative pressure. It's all in the manual. I can't tell you how...
  11. I would be calling those guys back and having it...

    I would be calling those guys back and having it installed correctly. You can't block off that much coil and expect it to work. You would be lucky if it hasn't damaged the system already.
  12. Replies
    42
    Views
    3,836

    I don't know Goodman products but I would go with...

    I don't know Goodman products but I would go with either a Honeywell IAQ or the comfort net control for dehumidification option. The Confort Net Control will give you fan control but the IAQ will...
  13. Replies
    6
    Views
    1,182

    You need to call a pro out before you burn some...

    You need to call a pro out before you burn some thing up.
  14. No, it shuts down the furnace to not over...

    No, it shuts down the furnace to not over pressure the heat pump during a defrost cycle. Lennox is the only one that I know that uses a tempering kit. I have disconnected most of the ones we have...
  15. Replies
    46
    Views
    6,179

    I guess that what I get for not reading the whole...

    I guess that what I get for not reading the whole post.
  16. The system is not setup properly. You need to...

    The system is not setup properly. You need to call the installer out to fix.
  17. Replies
    46
    Views
    6,179

    I don't know any commuticating system that would...

    I don't know any commuticating system that would even run if not wired correctly. I would have to say that it is not setup correctly.
  18. Replies
    16
    Views
    1,159

    I have to agree! The 6 gal is good for maybe a...

    I have to agree! The 6 gal is good for maybe a one bedroom apt. and can only use a 10' remote kit max. You need to size it for your home.
  19. Thread: AC Line Sets

    by jid1877
    Replies
    9
    Views
    773

    No, it would not make any difference.

    No, it would not make any difference.
  20. I am wrong, it will work with a 2 stage hp. But...

    I am wrong, it will work with a 2 stage hp. But it is not variable speed.
  21. That is a 2 stage heat and 1 stage cooling...

    That is a 2 stage heat and 1 stage cooling furnace. It is not variable speed and will not work with a 2 stage hp. That is why it is only wired for single stage operation.
  22. Replies
    5
    Views
    778

    He needs to read the Installation Instructions....

    He needs to read the Installation Instructions. The info is in there to wire correctly. Yes, you only have one stage of cooling with the way it is wire.
  23. Replies
    5
    Views
    778

    25HCB6 is a 2 stage HP. Your system is wired for...

    25HCB6 is a 2 stage HP. Your system is wired for 1 stage. You need to get the installer back out to wire the system for 2 stages.
  24. Replies
    7
    Views
    1,271

    No, it was a Guardian out on The Big Island.

    No, it was a Guardian out on The Big Island.
  25. Replies
    7
    Views
    1,271

    Ok, I guess since we don't deal with this brand...

    Ok, I guess since we don't deal with this brand and didn't even know what type of compressor it was supposed to be in it. I guess we should know what type of compressor goes into every brand of equip...