Search:

Type: Posts; User: schmuck

Page 1 of 6 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    2
    Views
    214

    I'm figuring a 10 SEER 4 ton but I'm not...

    I'm figuring a 10 SEER 4 ton but I'm not sure......
  2. Replies
    2
    Views
    214

    Trane unit size

    TWR748A100A2 Size, SEER and any other info would be appreciated.
    Thanks!
  3. Replies
    20
    Views
    806

    Ok sweet! Thank you guys for all of your help!

    Ok sweet! Thank you guys for all of your help!
  4. Replies
    20
    Views
    806

    Ok so after reading the post by "beenthere" I see...

    Ok so after reading the post by "beenthere" I see that it is. So, I may not have a problem at all then?
  5. Replies
    20
    Views
    806

    Yes it is. So are you telling me the metering...

    Yes it is. So are you telling me the metering device is inside the connection at/before the service valve?
  6. Replies
    20
    Views
    806

    The pressure drop we are referring to is the one...

    The pressure drop we are referring to is the one between the Vapor and LL Schrader valves.
  7. Replies
    20
    Views
    806

    In the heat cycle the ID coil is the condenser. I...

    In the heat cycle the ID coil is the condenser. I have no gage ports at all on my ID coil.
  8. Replies
    20
    Views
    806

    The liquid line and vapor line Schrader valves...

    The liquid line and vapor line Schrader valves are at the service valves of the OD unit. Therefore the LL Schrader is before the metering device of the OD coil making it the metering device inlet....
  9. Replies
    20
    Views
    806

    Same thing I was thinking but I wanted some...

    Same thing I was thinking but I wanted some reassurance. Thanks!
  10. Replies
    20
    Views
    806

    Heat Pump Question

    Looked at a Payne split system today that had a compressor changeout. The charge was weighed in and extra for lineset was calculated and added. In heat mode the pressures were between 30-40 low side...
  11. Replies
    17
    Views
    8,992

    NATE

    To be perfectly honest, I think the NATE test is a complete waste of time. Any person who has taken this test should be able to tell you that the questions are so far in left field that the test does...
  12. Replies
    25
    Views
    5,202

    305881305891

    305881305891
  13. Replies
    25
    Views
    5,202

    Mine is total metal. Looks like stainless but I...

    Mine is total metal. Looks like stainless but I don't think it is. I'm pretty sure it is nickel coated. It does have some plastic guards that are bolted to the sides and bottom of it though. These...
  14. Replies
    25
    Views
    5,202

    What did you use to "sweat" it back together?

    What did you use to "sweat" it back together?
  15. Thread: EPA TEST

    by schmuck
    Replies
    13
    Views
    866

    ACCA

    Look up ACCA on the web. That is the Air Conditioning Contractors of America. They have a book with a CD in the back with practice tests on it. you can practice at home and ace the test!

    ISBN#...
  16. Replies
    55
    Views
    4,945

    Are you on Dominion Power? If so you can a...

    Are you on Dominion Power? If so you can a contract from Nov. through March to get your heat pump energy usage cut in half if you put in a duel fuel heat pump. Check it out at dom.com
  17. Replies
    55
    Views
    4,945

    What is the efficiency of a fossil fuel burning...

    What is the efficiency of a fossil fuel burning plant?
  18. Replies
    55
    Views
    4,945

    Now look at the cost of equipment, repair of the...

    Now look at the cost of equipment, repair of the equipment and longevity.
  19. Replies
    55
    Views
    4,945

    On another note. We have only one source of...

    On another note. We have only one source of energy that is regulated. You know what that is? Electricity! Who knows what gas or oil prices might do but electricity will remain fairly constant.
  20. Replies
    55
    Views
    4,945

    This thread is funny to me. In our area in NC it...

    This thread is funny to me. In our area in NC it is cheaper to heat with resistance heat (strips) than it is to heat with gas. Besides the fact that gas is messy, dangerous and usually breaks down...
  21. Thread: Meat seasoning

    by schmuck
    Replies
    23
    Views
    2,431

    I dont use anything but salt on pork but for...

    I dont use anything but salt on pork but for chicken I use Tony Cacheres More Spice. Only place I can find it is at Bass Pro Shop.
  22. Replies
    12
    Views
    10,031

    Why on earth are you guys adding all that crap to...

    Why on earth are you guys adding all that crap to a good boston butt??? All you need to flavor it with is Kingsford or oak for about 6 hrs or so at about 250-275 degrees. I want to taste the smoke...
  23. Replies
    15
    Views
    2,042

    I have no idea......sorry

    I have no idea......sorry
  24. Replies
    26
    Views
    1,926

    Give me a little time. They are in my office at...

    Give me a little time. They are in my office at the college........John
  25. Replies
    15
    Views
    2,042

    The main reason I am saying this is because I...

    The main reason I am saying this is because I feel like your supply temperature should be warmer.........John
Results 1 to 25 of 126
Page 1 of 6 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event