  1. Replies
    5
    Views
    2,244

    I feel for ya, they always want to turn one thing...

    I feel for ya, they always want to turn one thing into another.
    Lets pack it jam tight full of product, and expect no effect on
    evaps airflow too. The important word here is BLAST.
  2. Thread: 404a charging

    by EdC
    Replies
    30
    Views
    3,208

    this can only end badly

    this can only end badly
  3. Replies
    16
    Views
    2,276

    verify that the clocks X will trip. That tripper...

    verify that the clocks X will trip.
    That tripper solenoid is an intermittent duty coil, and usually gets smoked
    when a noob mis-wires it.

    counter munkee: "No returns on electrical parts" ...
  4. Replies
    18
    Views
    1,378

    Cords worth a quarter

    Cords worth a quarter
  5. Replies
    21
    Views
    1,484

    I'm with the Poodle on this. Except on a long...

    I'm with the Poodle on this. Except on a long line LLV inside the evap.
    Just the TS bulb inside the box, and like every penetration... SEAL IT TIGHT
    Oh, and sparky dont put the sealtite connector...
  6. Replies
    26
    Views
    1,968

    I'm wondering if this isnt a CPR valve limiting...

    I'm wondering if this isnt a CPR valve limiting suction pressure during pulldown to keep
    the compressor within its happy zone.
  7. Thread: Heat Pump "Noise"

    by EdC
    Replies
    13
    Views
    1,836

    It has been my understanding that Copeland...

    It has been my understanding that Copeland scrolls in residential service
    have no need for CCH.
  8. Replies
    5
    Views
    552

    hissing, eh? is it kinda low like...

    hissing, eh?
    is it kinda low like pssssssssssssssss, or more
    like a high pitch pssshhhhhhhhh?

    sometimes its just old worn out gas.
  9. Assuming the wiring wasnt messed around with, and...

    Assuming the wiring wasnt messed around with, and it had been working correctly...
    Give the contactor a very good look see, or just replace it, and see if that
    caused the problem.
  10. Thread: Cool Stuff

    by EdC
    Replies
    8
    Views
    820

    Its a 'must have' for O-rings. A dab on flare...

    Its a 'must have' for O-rings.

    A dab on flare faces, and a bit behind the nut, work it in and out so
    that the area where the nut crushes the flare backside meet, this lets
    you get torqued...
  11. Replies
    22
    Views
    8,094

    Trying to figure the DC resistance of motor...

    Trying to figure the DC resistance of motor windings from only
    knowing 460VAC and 15A is gonna lead you astray.
    E/I wont help you at 60Hz and conductors wound around a
    chunk of steel. Inductance...
  12. Replies
    7
    Views
    8,875

    I dont think the NEC permits Class II (control...

    I dont think the NEC permits Class II (control voltage) wiring to share
    conduit with line voltage conductors. Besides, it invites problems.
  13. Replies
    28
    Views
    1,734

    If you get one with an old date code, be sure to...

    If you get one with an old date code, be sure to have the receipt if there
    is ever a warranty issue, without that the warranty period is based on the date of manufacture.

    Funny thing about supply...
  14. Replies
    8
    Views
    873

    I probably wouldnt add CPR to an existing MOP

    I probably wouldnt add CPR to an existing MOP
  15. Replies
    14
    Views
    2,982

    I bet it doesnt have a sump heater!

    I bet it doesnt have a sump heater!
  16. Replies
    16
    Views
    1,042

    So why not a 60A pullout disconnect, jeez.. way...

    So why not a 60A pullout disconnect, jeez.. way cheaper than a single breaker in a box.
  17. Replies
    5
    Views
    2,015

    how about electrostatic precipitation before the...

    how about electrostatic precipitation before the coil?
    filter, filter, then filter some more.
  18. Thread: 502

    by EdC
    Replies
    32
    Views
    2,595

    EAV1 -> EAVA

    looks like your EAV1-0200-TAC crosses to EAVA-021A the service replacement.

    8090btuh pumpin 502 @ LT
  19. Thanks for the warning

    Isnt the Enviro-Safe actually R-290 (propane)?

    I'm sure I dont want any part of some HO brew of
    refrigerants in my recovery tank.

    You're on your own with this.
  20. Replies
    17
    Views
    1,920

    I love this biz! You can call me first, or you...

    I love this biz! You can call me first, or you can call me last.. but you will call.
  21. Replies
    10
    Views
    760

    whoa! WHOA!! hold it right there pardner. ...

    whoa! WHOA!! hold it right there pardner.

    Suggesting exchanging the neutral for a second hot leg is WRONG. period.
    How will this provide for the existing 120V loads? Dont answer.

    The only...
  22. Replies
    458
    Views
    42,146

    I love the DRSA, mine is in the RYG livery, all I...

    I love the DRSA, mine is in the RYG livery, all I would critique is the thermistor wire choice. I sleeved it inside a heavier jacket.
    I would much prefer the wire type used on Cooper SH66.
    ...
  23. Replies
    17
    Views
    1,739

    sounds like fan delay closing a bit too early

    sounds like fan delay closing a bit too early
  24. Replies
    18
    Views
    1,930

    inquire if you can get their gas at cost

    inquire if you can get their gas at cost
  25. Thread: R134 and 134 auto

    by EdC
    Replies
    17
    Views
    8,434

    30# MVAC jugs are pure 134a, same as ACR, just...

    30# MVAC jugs are pure 134a, same as ACR, just different fittings and pricing.

    All retail pounders, "blowoff" cans have the Acme fitting, they are supplied as pure OR oil injection, usually a few...
Results 1 to 25 of 47