  1. Replies
    2
    Views
    112

    That is a relay. There are many things that can...

    That is a relay. There are many things that can cause the clicking. You'll have call a Pro to figure out what's going on.
  2. It looks like it has a plug in it? If not put a...

    It looks like it has a plug in it? If not put a plug in it.
  3. Replies
    17
    Views
    473

    udarrell, Take a look at the video in the first...

    udarrell, Take a look at the video in the first post.
  4. Replies
    17
    Views
    473

    OK I gotta ask, why did they put the unit 10 feet...

    OK I gotta ask, why did they put the unit 10 feet off the ground??
  5. Replies
    3
    Views
    99

    Aprilaire makes a good humidifier. If it was my...

    Aprilaire makes a good humidifier. If it was my decision I would go steam. They do make different size humidifiers.
  6. Coils don't come from the factory with copper...

    Coils don't come from the factory with copper sticking out of them. I'll bet it was hook up to a condenser at one time.
    I wouldn't take a chance on that coil.
  7. I think that might be a used coil.

    I think that might be a used coil.
  8. Where do the copper lines go, outside?

    Where do the copper lines go, outside?
  9. Replies
    4
    Views
    210

    Google Carrier zone stat.

    Google Carrier zone stat.
  10. Replies
    21
    Views
    821

    28* temp difference indicates a problem in your...

    28* temp difference indicates a problem in your system.
  11. Replies
    21
    Views
    821

    28* delta T?? Make sure your thermometer is...

    28* delta T?? Make sure your thermometer is reading right. Take it outside and put it in the shade.
  12. Replies
    7
    Views
    139

    Huh, replace the coil because the pan is...

    Huh, replace the coil because the pan is cracked???? Something's wrong here.
  13. Replies
    2
    Views
    130

    No, there is correlation between the fan and...

    No, there is correlation between the fan and refrigerant. If the unit cools for 45 mins the charge is probably OK.
  14. Replies
    4
    Views
    415

    I wouldn't even worry about it.

    I wouldn't even worry about it.
  15. Replies
    11
    Views
    427

    Some pic's would help us give you advise.

    Some pic's would help us give you advise.
  16. Replies
    2
    Views
    115

    The flue is on the front of the furnace and would...

    The flue is on the front of the furnace and would block the area where you would pull the filter out.
  17. Replies
    11
    Views
    293

    No you can't tell by looking at them. No DIY here...

    No you can't tell by looking at them. No DIY here so that's as far as I can go.
  18. Replies
    11
    Views
    293

    I don't think that problem has any thing to do...

    I don't think that problem has any thing to do with the installer. Does your stat have batteries?
  19. Replies
    11
    Views
    293

    I don't think that problem has any thing to do...

    I don't think that problem has any thing to do with the installer.
  20. Replies
    11
    Views
    293

    Tell us what the problem is and maybe we can tell...

    Tell us what the problem is and maybe we can tell if it's possible.
  21. Thread: Flashing lights

    by JES
    Replies
    15
    Views
    487

    If the red LED is blinking then you have a...

    If the red LED is blinking then you have a problem. Call a Pro.
  22. The SC and SH temps should tell him everything he...

    The SC and SH temps should tell him everything he needs to know to fix it. Find someone else.
  23. If it is flushed correctly, you will be OK.

    If it is flushed correctly, you will be OK.
  24. Replies
    5
    Views
    326

    It looks like it is a fan coil unit. It uses...

    It looks like it is a fan coil unit. It uses chilled water and hot water.
  25. Thread: Direction Needed

    by JES
    Replies
    5
    Views
    193

    Your right we can't discuss pricing here. I'm...

    Your right we can't discuss pricing here. I'm sure beenthere will stop by and let you know if we can PM you or not.
  26. Replies
    12
    Views
    368

    If your going to put in a package unit, then...

    If your going to put in a package unit, then there won't be anything in the attic.
  27. Replies
    12
    Views
    368

    IMO, furnaces don't belong in attic's. What till...

    IMO, furnaces don't belong in attic's. What till you have to go up there in the middle of the summer and change the filter.

    Yes you would be over sized just for the first floor. You will be...
  28. !. BULL!!!!! 2. Not a good idea. 3. I can't...

    !. BULL!!!!!
    2. Not a good idea.
    3. I can't imagine any repair that would cost that much.

    BTW, no pricing is allowed. They will edit it out.
  29. Replies
    11
    Views
    332

    Check the number that's on the compressor.

    Check the number that's on the compressor.
  30. Replies
    3
    Views
    220

    Seems reasonable to me too.

    Seems reasonable to me too.
  31. It looks like they have the stat staging the...

    It looks like they have the stat staging the cooling.
  32. Replies
    3
    Views
    197

    Sounds like the fan blade is hitting the cowling.

    Sounds like the fan blade is hitting the cowling.
  33. Replies
    3
    Views
    197

    Can't see the video.

    Can't see the video.
  34. Thread: AC not cooling

    by JES
    Replies
    20
    Views
    899

    I agree, he should have seen that the first time...

    I agree, he should have seen that the first time out there.
  35. And a little vibration.

    And a little vibration.
  36. You could replace the compressor but would cost...

    You could replace the compressor but would cost you as much as a new condenser.
  37. Ditto Doug. If the compressor dies you wouldn't...

    Ditto Doug. If the compressor dies you wouldn't want to replace it. Better off replacing the whole unit. If you have to make minor repairs, the parts are available.
    You might be able to get a few...
  38. Why do you want to change from 22 to 410?

    Why do you want to change from 22 to 410?
  39. Replies
    20
    Views
    686

    I think it sounds normal.

    I think it sounds normal.
  40. Yes, the stat should work on straight AC.

    Yes, the stat should work on straight AC.
  41. You have a delta T of 25*? Hmmm...

    You have a delta T of 25*? Hmmm...
  42. Replies
    8
    Views
    373

    My guess would be 1942.

    My guess would be 1942.
  43. Replies
    8
    Views
    483

    Yea, should have water in it.

    Yea, should have water in it.
  44. What do you have the pump connected to?

    What do you have the pump connected to?
  45. Hmmmm.... that seems to be the evaporator coil...

    Hmmmm.... that seems to be the evaporator coil model#.
  46. Replies
    14
    Views
    529

    The BTU's on a mini split and a window unit would...

    The BTU's on a mini split and a window unit would be the same.
  47. Same here in my part of the country.

    Same here in my part of the country.
  48. Replies
    29
    Views
    817

    I think you missed the comma.

    I think you missed the comma.
  49. In most cases a new disconnect isn't necessary.

    In most cases a new disconnect isn't necessary.
  50. Pricing is not allowed. Goodman is good...

    Pricing is not allowed. Goodman is good equipment but make sure the installers are top notch.
Results 1 to 50 of 177
Page 1 of 4 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Quality Home Comfort Awards