Search:

Type: Posts; User: rundawg

Page 1 of 20 1 2 3 4

Search: Search took 0.08 seconds.

  1. Replies
    13
    Views
    277

    You are not going to like this answer, but the...

    You are not going to like this answer, but the site rules do not allow DIY info to be given out. It states so at the top of the page (in yellow), and in the Forum rules.

    This forum is used to...
  2. Replies
    2
    Views
    72

    Check your email.

    Check your email.
  3. Sorry that I'm a little late to the parade on...

    Sorry that I'm a little late to the parade on this one, I didn't see this before. It might be OBE (overcome by events) and you have probably already figured this out, but if you are still wondering:...
  4. Replies
    5
    Views
    153

    Fair enough. Best of luck to your exploration.

    Fair enough. Best of luck to your exploration.
  5. Replies
    5
    Views
    153

    It wouldn't be the first time I couldn't figure...

    It wouldn't be the first time I couldn't figure out what someone was trying to say over an internet conversation.

    Back to my original question, and still my point of confusion, are we talking...
  6. Replies
    5
    Views
    153

    I'm going to try and read between the lines here,...

    I'm going to try and read between the lines here, so please enlighten me if I'm way off target.

    If I'm understanding you correctly, you are asking about reading the temperature of the coil sensor...
  7. Replies
    1
    Views
    124

    Refer back to your other post on the Trane...

    Refer back to your other post on the Trane defrost control for my comments.

    We don't post manuals or technical data in this "OPEN" forum.
  8. Thread: trane XE11000

    by rundawg
    Replies
    3
    Views
    238

    Without going into too much detail in this "OPEN"...

    Without going into too much detail in this "OPEN" forum, 3 flashes can be one of two things:

    1. Defrost cycle has terminated on time, instead of temperature.

    2. High delta T (relationship...
  9. Replies
    6
    Views
    152

    That looks close to what you have. If you had...

    That looks close to what you have.

    If you had an email address in your profile, I would email a copy to you.

    If you don't want to wait for your access to Rheemote, you can email me (address is...
  10. Replies
    1
    Views
    240

    I emailed you the only bulletin I know of for...

    I emailed you the only bulletin I know of for this unit that relates to ignition issues.
  11. Replies
    12
    Views
    379

    There should be a retainer that holds the piston...

    There should be a retainer that holds the piston in place inside the service valve.

    The retainer does come out.

    I sent you an email of what it should look like.
  12. Replies
    5
    Views
    324

    I think you meant 130 cfm here - correct? ...

    I think you meant 130 cfm here - correct?

    Natural draft furnaces should be at least 100 cfm /10,000 btuh input.
  13. Replies
    65
    Views
    2,420

    Only if he had a considerably smaller than...

    Only if he had a considerably smaller than required piston installed. He actually has a slightly larger than required piston installed, so it should be allowing more refrigerant through it than what...
  14. Replies
    5
    Views
    306

    As others have said, it depends on the...

    As others have said, it depends on the manufacturer, and if you are talking Recips or Scrolls.

    Trane had 2 compressor systems, where one compressor was half the tonnage of the other (2 ton-low and...
  15. Replies
    65
    Views
    2,420

    As far as I know, an assumed site rule for the...

    As far as I know, an assumed site rule for the "OPEN" forums. I haven't read the fine print.

    As I stated, you are doing a great job with this kid (I'm assuming he is a kid).

    My problem is, we...
  16. Replies
    65
    Views
    2,420

    Always try to use the manufacturers specs for the...

    Always try to use the manufacturers specs for the unit you are working on and not a generic chart from an online source that sells HVAC equipment.
  17. Replies
    65
    Views
    2,420

    I see you found one of the sources for the proper...

    I see you found one of the sources for the proper piston size. The other is the units technical specs manual.

    I don't post manuals or technical information in this "OPEN" forum.

    You are doing a...
  18. Replies
    65
    Views
    2,420

    Neither. Manual says 0.065 for the 2.5 ton unit.

    Neither. Manual says 0.065 for the 2.5 ton unit.
  19. Replies
    3
    Views
    283

    The 30/5 mfd 370 volt capacitor is the correct...

    The 30/5 mfd 370 volt capacitor is the correct capacitor.

    The 35/5 mfd capacitor is about 16 - 17% over the required capacitor rating for that compressor. Most technicians will change a capacitor...
  20. Thread: AAON problem

    by rundawg
    Replies
    2
    Views
    261

    All I have is the Installation Manual. If you...

    All I have is the Installation Manual. If you want it, send me an email (address is in my profile), and I will get it off to you.

    If you put an email address in your profile, or make your requests...
  21. Replies
    4
    Views
    243

    Most York Demand Defrost controls will terminate...

    Most York Demand Defrost controls will terminate the defrost cycle after the liquid line temperature reaches 80F, or after eight minutes of defrost operation.
  22. Replies
    4
    Views
    243

    Those should be 10k-2 (type 2) thermistors. A...

    Those should be 10k-2 (type 2) thermistors. A temp of 31f should be around 33.5K ohms. Your 40K is about 25f.

    This unit does not use time/temp to initiate defrost, but has a Demand Defrost...
  23. Replies
    2
    Views
    299

    Assuming you have a HK06WC090 pressure switch in...

    Assuming you have a HK06WC090 pressure switch in this unit, the tech guy was correct - the switch should make at 0.33" wc, and break at 0.13" wc .
  24. Replies
    7
    Views
    450

    They do like to make it challenging.

    They do like to make it challenging.
  25. Replies
    7
    Views
    450

    I have a Trane chart with this serial number...

    I have a Trane chart with this serial number format.

    F45583619

    F - 1991

    45 - week of manufacture

    583619 - sequence #
Results 1 to 25 of 500