Search:

Type: Posts; User: shavedneon

Page 1 of 17 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    13
    Views
    409

    He may have a two stage unit, to provide the...

    He may have a two stage unit, to provide the short run time (inefficient) and the long run times (more efficient). Maybe OP will understand a car analogy, it's like the mpg listing on your car, stop...
  2. Replies
    1
    Views
    67

    Disappointed in Honeywell

    Found this today
    http://uploads.tapatalk-cdn.com/20160727/47563d645fbce3ae1155856c0a4b1728.jpg
    It's the retail version of a focus pro 6000, the "pro" version that we buy only reads two digits,...
  3. I too like mine, and the price is reasonable.

    I too like mine, and the price is reasonable.
  4. Replies
    55
    Views
    2,039

    The new metal m12 light from Milwaukee looks...

    The new metal m12 light from Milwaukee looks promising, it will most likely replace my rechargeable streamlights. And it runs on the m12 batteries, that many of us already have several of with...
  5. http://hvac-talk.com/aop

    http://hvac-talk.com/aop
  6. Check out contractor locator map, I know the...

    Check out contractor locator map, I know the Georgia guys have had a few get togethers. So they're around, typically the guys on here are all HVAC all the time. You're more likely to find a...
  7. Replies
    20
    Views
    701

    The coil is installed backwards, all the...

    The coil is installed backwards, all the connections are back there
  8. Replies
    20
    Views
    701

    Good job on the radius inside throat on the...

    Good job on the radius inside throat on the elbow, I wish I saw that more.
  9. You could take a highly calibrated tool, like two...

    You could take a highly calibrated tool, like two foot of toilet paper to see if it is sucking air into it. If it is, it's hooked up to something, if you have access to the attic, you could just look...
  10. That is a duct-less mini split, the duct work in...

    That is a duct-less mini split, the duct work in the ceiling goes to something else. Perhaps abandoned when it wasn't enough air to support to room effectively. The mini split should be enough to...
  11. Unless it's a ducted mini, or a soffit fan coil

    Unless it's a ducted mini, or a soffit fan coil
  12. No problem, you're almost there

    No problem, you're almost there
  13. Yup, can post pics until several posts, like 5 or...

    Yup, can post pics until several posts, like 5 or 7 or something, tell us a little more about, the AC, home, your location, or yourself.
  14. It depends on what model of Mitsubishi it is,...

    It depends on what model of Mitsubishi it is, there are certain models that allow ducting to connect to the air handler. Can you post the model number or post pics. I'm having a difficult time...
  15. I KNOW we have several very good Georgia guys...

    I KNOW we have several very good Georgia guys here, I don't think GA has posted on this thread, I'll try to get his attention. A few mods/admin too. Someone local will be along shortly.
  16. Where are you located? Perhaps one of us know a...

    Where are you located? Perhaps one of us know a good tech in your area.
  17. Replies
    5
    Views
    964

    That's one of the problems with different trades...

    That's one of the problems with different trades all dealing with the same unit. I've read how some of you guys have electricians hook up the high voltage, controls guys hook up low voltage, plumbers...
  18. We had a home several years ago with similar...

    We had a home several years ago with similar problems, the lines ran thru the exterior wall right by the headboard in the master suite. We tried several remedies to stop the noises, we removed the...
  19. Replies
    17
    Views
    602

    How much duct work was replaced with this unit?...

    How much duct work was replaced with this unit? If the old system had radiused inside throat elbows and the new one has square inside throat, that would explain it. Possibly adding turning vanes...
  20. Beenthere is one of the guys on here I wouldn't...

    Beenthere is one of the guys on here I wouldn't want to disagree with, but we've been installing 20" round flex on 3 ton systems for years, R8 if outside envelope, R6 if inside. No adverse heat gain,...
  21. Replies
    16
    Views
    719

    Are you describing a clunk as the compressor...

    Are you describing a clunk as the compressor shuts off? Maybe it sounds like one marble in a five gallon bucket that just clunks once, when unit shuts down? Or a constant ticking? I have heard...
  22. Replies
    9
    Views
    480

    Tons of holes in evap coils, when pressurized and...

    Tons of holes in evap coils, when pressurized and under water it looks like a fish tank stone. But haven't seen any problems in line sets, that were not from rubbing thru, or a bad weld joint. Ever,...
  23. Replies
    21
    Views
    1,535

    Is there a label on the bigger unit? Says...

    Is there a label on the bigger unit? Says "OUTDOOR UNIT" because that would make it funnier. I've seen this in pictures before, but not this particular picture, classic.
  24. Replies
    50
    Views
    2,513

    I can't find my 09, (did find 00,03,and06) I have...

    I can't find my 09, (did find 00,03,and06) I have the section bookmarked, googled a couple things. I believe it was the mechanical fasteners required, it's been a while since we dealt with it, all...
  25. Replies
    50
    Views
    2,513

    Recent install

    The appliance connectors are required here, due to it being considered an earthquake zone, it can not be hard piped. Each area has different restrictions, sometimes our inspectors will pull something...
  26. Replies
    126
    Views
    2,905

    Aluminum line set???

    The strippers don't cut far enough, there's a hole left when closed for the wire, whereas the cap tubing cutter cuts all the way thru....
  27. Replies
    126
    Views
    2,905

    I found it!...

    I found it!
    http://uploads.tapatalk-cdn.com/20160704/40afe3033e37f98f9329c2919d6062b1.png
    http://uploads.tapatalk-cdn.com/20160704/83342681525efa4f2180203573996945.png...
  28. Replies
    126
    Views
    2,905

    I found this one at an appliance store locally,...

    I found this one at an appliance store locally, it was just on a piece of cardboard shrink wrapped. No markings or makers mark. I think it was $7.99 or something like that. I did look online and...
  29. Replies
    126
    Views
    2,905

    I'm not familiar with the file method, I...

    I'm not familiar with the file method, I purchased a capillary tube cutter. It looks very cheap but does an excellent job cutting....
  30. Replies
    126
    Views
    2,905

    Aluminum line set???

    Good idea, permanently mounted gauges, I'm picturing cap tube size lines for the liquid line. Like 1/16" for LL, and 3/16" for suction line, it'd look like a plate a spaghetti noodles for line set....
  31. Replies
    126
    Views
    2,905

    A few ounces, what's a smaller measurement, grams...

    A few ounces, what's a smaller measurement, grams maybe? Would need a smaller more accurate scale, or maybe precharged small cans.
  32. Replies
    126
    Views
    2,905

    Imagine how perfect the charge needs to be on...

    Imagine how perfect the charge needs to be on that little one.
  33. Replies
    126
    Views
    2,905

    Aluminum line set???

    What brand of wine cooler? I'm interested in learning more about that, sounds way cool. -Edit-wow, I think I owned one of these and didn't even know it, was a gift for my wife. That's fascinating...
  34. Replies
    126
    Views
    2,905

    Aluminum line set???

    I had a warranty company call to a new neighborhood still new homes being built, the whole neighborhood has aluminum line sets, but copper connections at both ends, if I remember correctly had five...
  35. Replies
    58
    Views
    1,457

    Just in case some of you guys don't know, the...

    Just in case some of you guys don't know, the classic ductulator has all this information on the back. And it's for metal duct not flex duct.
  36. Replies
    10
    Views
    392

    W/H looks like gas

    W/H looks like gas
  37. Replies
    10
    Views
    392

    From the pictures, if this were here (in...

    From the pictures, if this were here (in Arizona), it appears that the 6" duct would be a combustion duct, that should be located at or within 12" of the ceiling. We are not allowed to use flex duct,...
  38. Replies
    10
    Views
    392

    Can you post a picture? If it's not attached to...

    Can you post a picture? If it's not attached to anything in the mechanical room, it MIGHT not be needed. If it's just beside the furnace, it's most likely not installed as it should be. Hopefully...
  39. Replies
    10
    Views
    392

    I'm sorry, I don't know the regulations of...

    I'm sorry, I don't know the regulations of Ontario. But I am curious about what you are referring to, is the "fresh air intake" flex running to the furnace body itself? Or leading to combustion and...
  40. Replies
    26
    Views
    1,551

    Very nice looking, I would prefer one piece...

    Very nice looking, I would prefer one piece liquid line, using bender instead of all those elbows. It does look very nice tho.
  41. 84 inside, wife finally made me fix my unit

    My 3 ton dual compressor Trane package unit stopped working on Father's Day, second stage calling, temp up to 81 set point at 76, I replaced both compressors under warranty last year. ODA 122, I...
  42. Replies
    7
    Views
    331

    Are your existing returns in the ceiling or high...

    Are your existing returns in the ceiling or high on a wall or low on the wall? There may not of been enough room for the ductwork to run all the way up to the ceiling of the upstairs, but perhaps if...
  43. Where are you located? That size unit would NOT...

    Where are you located? That size unit would NOT work in my area, in Arizona. You would ideally have a heat load performed to figure out what size unit you need. There's a free site at heatload dot...
  44. Replies
    45
    Views
    3,572

    Is the TXV sending bulb in the right location? ...

    Is the TXV sending bulb in the right location?
    700651
    I think this is the same model
  45. Replies
    45
    Views
    3,572

    That repair is amazing. I'm impressed that it's...

    That repair is amazing. I'm impressed that it's holding pressure. I wonder what the rated pressure is on those flex lines. I'm pretty sure that copper is thinner than the refrigeration copper is....
  46. Replies
    13
    Views
    692

    Move to Arizona, it will be fun

    Just because I took the picture to send to the office to explain.
    http://uploads.tapatalk-cdn.com/20160617/0e197b4eb9c8b99dcd809cfa1b7af1d3.jpg
    Attic temp, repairing a coil install, another tech...
  47. Replies
    2
    Views
    368

    those pumps can be finicky, I've found they need...

    those pumps can be finicky, I've found they need to be primed and not allowed to run dry, a few have been perfectly quiet when installed (during monsoon season) and next season on start up, are so...
  48. Replies
    24
    Views
    1,004

    http://uploads.tapatalk-cdn.com/20160616/bbbb90b6e...

    http://uploads.tapatalk-cdn.com/20160616/bbbb90b6e275cbaafa967b28551ec93e.jpg
    I picked this one up a few years back, it's perfect for those compressors that are not the standard scroll type, size...
  49. AFAIK, both portables and window units are...

    AFAIK, both portables and window units are appliances and are not held to the same efficiency standards. Your electric bill may be much higher with those, than if you had a minisplit. Garage door...
  50. What's the R value of the armor flex at the...

    What's the R value of the armor flex at the indoor unit? Insul-tube? What is it called, I think those are brand names, it looks nice and thick, many years ago we had to switch suddenly, inspectors...
Results 1 to 50 of 849