Search:

Type: Posts; User: jim bergmann

Page 1 of 20 1 2 3 4

Search: Search took 0.05 seconds.

  1. Replies
    8
    Views
    261

    The RH board needs to be plugged into the probe...

    The RH board needs to be plugged into the probe board to work, and it actually plugs in what would look like upside down looking at the board. If it is put in wrong it simply will not power up, but...
  2. Replies
    8
    Views
    261

    Before you send it in, call and ask to talk to...

    Before you send it in, call and ask to talk to Eric. There are a few things that we can check and sometimes resolve in the field without a return. Sometimes if a probe gets dropped, there is an...
  3. Replies
    25
    Views
    703

    When using the repeater, you need to carry the...

    When using the repeater, you need to carry the repeater to a point where you can see the pressure probes and the indoor probes communicating on your smart device. Stand at that location with the...
  4. Replies
    1,150
    Views
    123,589

    None at all.

    None at all.
  5. No account needed You do need to profile the...

    No account needed

    You do need to profile the system every time for most diagnostics, however you can make quick profiles to speed up the process

    The iConnect can not tell you targets without...
  6. Replies
    1,150
    Views
    123,589

    Call customer service in the AM. They will send...

    Call customer service in the AM. They will send you one out.


    http://imanifold.com/contact-us/
  7. Replies
    137
    Views
    23,738

    Nope, we sold the Stride name and the Imperial...

    Nope, we sold the Stride name and the Imperial brand. We wanted to focus solely on the iManifold and training units. Same people, same owners, same product, now North Park Innovations in NY, with a...
  8. Replies
    25
    Views
    703

    If you carry the iConnect with you, you will...

    If you carry the iConnect with you, you will likely never have problems as you are taking advantage of the Zigbee network and a much better wireless system, you never loose BT because you are...
  9. Replies
    1,150
    Views
    123,589

    and this one ...

    and this one


    https://www.youtube.com/watch?v=RV5InLDrXoA
  10. Replies
    1,150
    Views
    123,589

    Likely you have your probes to close to the AHU,...

    Likely you have your probes to close to the AHU, see these two videos, they will really help.

    Jim


    https://www.youtube.com/watch?v=8758RWlNDdc
  11. Replies
    1,150
    Views
    123,589

    Yes, all of the reports, storage and tech-connect...

    Yes, all of the reports, storage and tech-connect come with the subscription, they are all unlimited.
  12. Replies
    1,418
    Views
    225,515

    3d, The S7 is not fully supported on the...

    3d,

    The S7 is not fully supported on the current release of software. If you can get me your Google Pay ID, I will add you to the beta test group and you can test out the new software. It will...
  13. Replies
    1,150
    Views
    123,589

    Not yet, it is still on the roadmap, but it has...

    Not yet, it is still on the roadmap, but it has been bumped a few times for other feature adds.
  14. Profiling Operation with the iManifold

    I put together this video, and a few more to follow for a very specific reason. I see a lot of videos of technicians using the iManifold without using one of the most powerful features, system...
  15. Replies
    159
    Views
    17,160

    The Testo does not use a temperature compensated...

    The Testo does not use a temperature compensated pressure transducer, and is likely really designed for air-conditioning applications not refrigeration. That said, you would have to rezero the...
  16. Replies
    1,150
    Views
    123,589

    You can still leave the wire velcroed to hose and...

    You can still leave the wire velcroed to hose and connect and disconnect the hose as needed. I do that also depending on how I store it.
  17. Replies
    1,150
    Views
    123,589

    Have you seen this? This is how I do it. ...

    Have you seen this? This is how I do it.


    https://youtu.be/BxhSNzAR7ks
  18. Replies
    1,150
    Views
    123,589

    We do have these available, and a lot of guys...

    We do have these available, and a lot of guys like them.

    http://imanifold.com/product/thermistor-pipe-clamp-surface-probe-905m/

    I have considered wireless probes, but the cost is really high...
  19. Replies
    1,150
    Views
    123,589

    In you application, if I can lift up a lay-in...

    In you application, if I can lift up a lay-in register, I just lift it up and put the tip down into the boot. I have even just set the whole probe into the boot if it is not a straight down drop. You...
  20. Replies
    1,150
    Views
    123,589

    Duct leakage is exactly why I recommend doing it...

    Duct leakage is exactly why I recommend doing it that way. That is a huge opportunity to correct a large efficiency loss in the system. If there is not duct leakage the system performance is fine, if...
  21. Replies
    1,150
    Views
    123,589

    When it comes to probe placement, don't get...

    When it comes to probe placement, don't get "appliance fixation" the probes are wireless! I recommend if you have a central return, put the RA probe in the filter grill and the SA probe right into...
  22. Replies
    1,150
    Views
    123,589

    It was a rare occurrence, where you had to delete...

    It was a rare occurrence, where you had to delete and reinstall the application. There was a conflict in the database that was affecting the probe mapping. It was the first time that I had seen it.
  23. Replies
    1,150
    Views
    123,589

    Sure if you have time, now is fine

    Sure if you have time, now is fine
  24. Replies
    1,150
    Views
    123,589

    Give me a call on this on this one. I will see if...

    Give me a call on this on this one. I will see if we can figure it out.

    Jim

    330 six one eight 3472
  25. Replies
    1,150
    Views
    123,589

    It's still on the roadmap.

    It's still on the roadmap.
  26. Replies
    1,150
    Views
    123,589

    Ok, I understand, your RA probe is simply not...

    Ok, I understand, your RA probe is simply not mapped. Navigate to the probe, tap the temperature or humidity subscript and a pop up will come up. Change it to return air and it will be fine.
  27. Replies
    1,150
    Views
    123,589

    Wet bulb is set in the measurement screen. The...

    Wet bulb is set in the measurement screen. The probes read temp and RH and calculate wetbub so there is for sure nothing wrong with your report. The snapshot is not "stored" the report generated with...
  28. Replies
    1,150
    Views
    123,589

    Typically the only thing that will cause a probe...

    Typically the only thing that will cause a probe transducer to fail is getting them wet. With the temperature ports it is easy to get water in the probes if you do not remove them when doing things...
  29. Replies
    1,150
    Views
    123,589

    Battery indicators simply are that. Different...

    Battery indicators simply are that. Different cells act differently under a load, and when batteries get low you can experience erratic readings and behaviors.
  30. Replies
    1,150
    Views
    123,589

    You might try to simply force all the probes out...

    You might try to simply force all the probes out of the network by pressing and holding the wireless button on each probe and deleting them from the application then reinstalling them. The iConnect...
  31. Replies
    1,150
    Views
    123,589

    Here is the support page, it will get you right...

    Here is the support page, it will get you right to a person. http://imanifold.com/contact-us/ There is a number at the bottom. We will get you squared away.
  32. Replies
    1,150
    Views
    123,589

    I got your contact information from Bill Spohn,...

    I got your contact information from Bill Spohn, some are on the way. They can be glued in with a drop of superglue.

    Jim
  33. Replies
    1,150
    Views
    123,589

    They can, the brass on the pressure probe might...

    They can, the brass on the pressure probe might get damaged or dinged on the threads if they hit on the tip, but we did the RH probes, repeater and micron gauge without damage.
  34. Replies
    1,150
    Views
    123,589

    We drop test everything. Here is an example....

    We drop test everything. Here is an example. http://youtu.be/y_1G0yPqQkY
  35. Replies
    1,150
    Views
    123,589

    The magnets are actually about 1 lb pull strength...

    The magnets are actually about 1 lb pull strength each. (5 total). We did do a lot of testing, and they do work OK if you drill the hole properly even in a vertical position. The primary issue we...
  36. There is an issue with the latest version of...

    There is an issue with the latest version of Android that we are in the process of fixing that affected the Bluetooth connection in the iManifold application. We are planning on having the fix out...
  37. It should be a simple as turning on the meter...

    It should be a simple as turning on the meter with Bluetooth on and pressing the connect button. That is a Bluetooth LE meter, no pairing required. That said, make sure that you completely close out...
  38. Replies
    1,150
    Views
    123,589

    There are no limit to the free reports. There are...

    There are no limit to the free reports. There are two things that might be happening.

    1) You are starting a new project and you are simply not seeing your other reports.

    2) If you updated to...
  39. Replies
    1,150
    Views
    123,589

    I believe they have it fixed for the next...

    I believe they have it fixed for the next release. I will verify tomorrow.
  40. Replies
    1
    Views
    325

    I think we are safe for the next few months, but...

    I think we are safe for the next few months, but it will not surprise me when they do start heading that direction. It is only a matter of time.
  41. Replies
    5
    Views
    501

    It is just like remembering to set it to any...

    It is just like remembering to set it to any other setting. Not a big deal. It has a pretty cool application outside of using it with the iManifold. Feature for feature it is a really power packed...
  42. Replies
    1,150
    Views
    123,589

    I can have those added. Are you thinking that you...

    I can have those added. Are you thinking that you would like to see them all at once or switch between them?

    Dry bulb, RH, Wet bulb, dew point in and out?
  43. Replies
    1,150
    Views
    123,589

    Yes, that is a limitation of wireless, we are...

    Yes, that is a limitation of wireless, we are making 4 readings/second, but there are a ton of readings coming off the wireless probes. We are working on a "turbo read" that would read a single probe...
  44. Replies
    1,418
    Views
    225,515

    Chillers and Geothermal are on the development...

    Chillers and Geothermal are on the development roadmap. Working on a few other cool projects at the moment. We will have a lot to talk about in the next few months. Stand by.

    Jim
  45. Replies
    1,150
    Views
    123,589

    That is working fine for us. Make sure your app...

    That is working fine for us. Make sure your app is up to date. Also if using Apple, try restarting your device. The reason software updates apple did requires the phone to be powered off and on once...
  46. Replies
    1,150
    Views
    123,589

    I will have the guys look at it. There was a...

    I will have the guys look at it. There was a recent Android update (Android OS update) that is causing problems on some devices. It is an Android issue out of our control. There is a fix, but let me...
  47. Replies
    12
    Views
    677

    The coldest the liquid can get is the ODA...

    The coldest the liquid can get is the ODA temperature. What you are effectively doing is raising the head pressure and the condenser being so far oversized for the load is still getting the liquid...
  48. Replies
    1,150
    Views
    123,589

    Yes, same for an air conditioner, heat pump, or...

    Yes, same for an air conditioner, heat pump, or furnace. Any airside measurement. Could even be a hot or chilled water coil with an alternative airflow measurement.

    Jim
  49. Replies
    1,150
    Views
    123,589

    I will see if it is definitive, but it is driven...

    I will see if it is definitive, but it is driven of outdoor air temperature and split.
  50. Replies
    1,150
    Views
    123,589

    It is a very high end sensor, excellent low range...

    It is a very high end sensor, excellent low range resolution. Does extremely well with a Pitot tube to measure air velocity, and high enough resolution for zonal depressurization. We are going to be...