Search:

Type: Posts; User: safwan

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Replies
    4
    Views
    336

    Point to Point Dial Up Connection

    How Point to Point Connection is achieved on Dial Up connection ?
  2. Replies
    3
    Views
    304

    Iam fine...and totally agrees with your...

    Iam fine...and totally agrees with your comments...As i myself have knocked my head fighting with the consultants...who wants to stick to their copied specs...
  3. Replies
    3
    Views
    304

    Integration and Monitoring VFC points

    Hey folks....

    Have the glitch regarding the Integration...and Monitoring points.

    I had been through many of the estimation of the projects...as the control drawing from the clients indicate...
  4. Replies
    1
    Views
    268

    PCC-10 Echelon card Error

    Hi...guys.

    Iam facing a problem related to the Installation of the PCC-10 Echelon card.

    I was trying to install the PCC-10 PC LonTalk Adapter using LDV 4.0...but iam getting error when...
  5. Thread: CAV & VAV

    by safwan
    Replies
    1
    Views
    477

    CAV & VAV

    What is diffrence between CAV & VAV ?

    I mean by VAV, Temperature is achieved by controlling pressure, but in case of CAV there is no pressure...then how temperature is achieved.
  6. Thread: CASCADING

    by safwan
    Replies
    2
    Views
    579

    CASCADING

    Hey...Guys.

    Just wanna know...how cascading is achieved by using a one VFD going for 6 secondary pumps.
  7. Replies
    1
    Views
    541

    963 Supervisior- Trend Controls

    Hi Folks,

    How to take the reference of Graphs in 963 supervisor from the Controller.
  8. Replies
    2
    Views
    430

    TREND CONTROLS & CARRIER GTN100

    Hi folks,

    Got a glitch for integrating Carrier GTN100-series chiller of quantity 2 along with Graphics.

    firstly need to know GTN100 chiller communicating protocol....is it MODBus or BACnet ?
    ...
  9. Replies
    2
    Views
    930

    TREND CONTROLS - THERMOSTAT

    Hi...folks,

    got a problem in selecting the thermostat for package units.... there is One DPG which compromises of 3-PACU serving different zones.

    I had selected the IQ3 controller along with IO...
  10. Replies
    2
    Views
    365

    TREND INTERFACES.........

    Did anyone have information about the Trend Interfaces by Eelctrocom (http://www.electrocom.dk/2-home.html ?

    Any Information ?
  11. Replies
    1
    Views
    590

    TREND LAN NETWORK

    Hi Folks,

    I am estimating one project which consist of 3 floor with 15 DDC Panel on each floor & 501-Third Party BACnet MS/TP Networkable FCU's ....as this project was installed as standalone...
  12. Replies
    2
    Views
    806

    Thanks Denhvax....you can find the my email...

    Thanks Denhvax....you can find the my email address in my profile....iam waiting for your mail.
  13. Replies
    11
    Views
    1,799

    OK Agreed.....But if iam gonna use...

    OK Agreed.....But if iam gonna use IQ3XCITE/128/BAC/24 or/230 for each panel. i had to use the network switches in each building and to connect workstation, i had to use fiber optic cable to connect...
  14. Replies
    2
    Views
    806

    TREND CONTROL- VISIO STENCILS

    Does anyone have visio stencils of Trend controls ? As i have to used in risers.....and dont wanna go for Autocad models.
  15. Replies
    11
    Views
    1,799

    IQ3/LAN -TREND CONTROLS

    Hi Guys,

    Iam estimating a Project which consist of 4 buildings with 10 DGP Panels each, the distance of each is building is >200<250 meters to other.Iam considering IQ3XCITE/128/LAN/240...
  16. Replies
    4
    Views
    668

    TREND CONTROLS UPGRADE

    Hi folks.......Need Help.

    I got an inquiry which compromises 300-FCU's and 16-AHU'S which is working as standalone system, but based on a product TAC Vista LON Controls.the client do not want to...
  17. Replies
    4
    Views
    1,138

    Thanks Orion.........for sharing this...

    Thanks Orion.........for sharing this information.....But again....I had a glitch regarding the Thermostats.

    Agreed....As per your information for TB/TS means, it require hardware inputs such as...
  18. Replies
    4
    Views
    1,138

    Trend IQVIEW & IQECO

    Hi Folks........Need information based on Iqview & Iqeco.

    There is 3 Types of IQVIEW series..........as IQVIEW, IQVIEW4 & IQVIEW8.

    IQVIEW : IQView display that provides a self-configuring user...
  19. Thread: TREND CONTROLS

    by safwan
    Replies
    5
    Views
    1,222

    Need More........Elaboration dude.

    Need More........Elaboration dude.
  20. Thread: Trend Honeywell

    by safwan
    Replies
    9
    Views
    1,778

    Thanks for the Information......Yes Iam working...

    Thanks for the Information......Yes Iam working on Trend as Newbie on this Product.
  21. Thread: Trend Honeywell

    by safwan
    Replies
    9
    Views
    1,778

    Iam Proposing 963S in a Project which will be...

    Iam Proposing 963S in a Project which will be installed in workstation and can also be used as 3 web seats. Once the software in installed in workstation with license , can install this software with...
  22. Thread: Trend Honeywell

    by safwan
    Replies
    9
    Views
    1,778

    Trend Honeywell

    Hi Folks....

    Got a glitch for selecting the Operator software.

    For a Workstation i had selected "963S/CD/3USER" 963 server plus 3 web clients. I need to do standalone T&C through local Laptop,...
  23. Replies
    1
    Views
    552

    Trend Damper : ADS10-P, ADS20-P

    Hi guys.....I need to know about this Floating/Modulating dampers, that If Iam considering the Dampers ADS10-P, ADS20-P , Does Auxiliary Switch " ACCA-AD2034-SW2 " is essential for this ?

    As I...
  24. Replies
    2
    Views
    1,008

    KMC BACstage file have a extension of .BAC files,...

    KMC BACstage file have a extension of .BAC files, first check whether it can work with .bac files.iam sure if it is bacnet compatible it can work with both BACstage and Total Control.
  25. Replies
    6
    Views
    1,082

    Trend Third Party

    Is the other workstation is neccessary with equivalent to BMS workstation, if we are using the third party integration for "TONN" gateways.
  26. Replies
    3
    Views
    717

    Man Days Engineering

    Hi folks,

    How do i consider the man days engineering for the control & Monitor for the following machines.

    1.AHU'S
    2.CHILLERS
    3.FAN COIL UNITS
    4.VAV'S
    5.PACU
    6.PLUMBING SYSTEM
  27. Thread: Trend controls

    by safwan
    Replies
    5
    Views
    1,535

    yes they offer the ECO-VAV-PA here. Is it a...

    yes they offer the ECO-VAV-PA here.

    Is it a networkable controller with a full options for Pressure independent and Pressure dependent ?
  28. Thread: Trend controls

    by safwan
    Replies
    5
    Views
    1,535

    Trend controls

    Hi Everyone,

    Started working on Trend Product, I had a glitch regarding the selection of FCU & VAV Controllers, as the points to be controlled and monitor has not been given by client, as for the...
  29. Replies
    3
    Views
    1,314

    Honeywell Comfort Point Programming Software

    I need Comfort point programming software for Honeywell...............does any one have or any link.
  30. CRESTRON -Integration with GLA-BMS Feild Server Gateway

    Iam having a gateway from crestron which is supporting lonworks protocol ft-10.
    how can i integrate it with TAC Vista?

    Do i need the XIF file for that device integration ?

    kindly find link......
  31. Thread: ROAMIO-2

    by safwan
    Replies
    1
    Views
    697

    ROAMIO-2

    I am doing a estimation in which there is 10 different AHU Panels and the client needs operator display for individual Machine, I had selected "XP-Display-10' for each machine ( each for single...
  32. Replies
    2
    Views
    1,255

    Just need to know , as one of my friend is...

    Just need to know , as one of my friend is working on comfortpoint and the controllers are same as of KMC , thought the programming may be the same....but no problem....thanks:whistle:
  33. Replies
    2
    Views
    1,255

    KMC & Honeywell Comfort Point Programming

    Did any one has done Honeywell comfort point programming ? Which type of language does Honeywell use ? Is it plain english language as of KMC ? Can anyone had done progamming ? if yes , can anyone...
  34. Replies
    7
    Views
    674

    I had worked on KMC Controls and have idea of...

    I had worked on KMC Controls and have idea of doing the control basic programming, I understand your point , you may be using the MAX() to get the maximum temperature, use the mac address of the...
  35. Thread: BMS Estimation

    by safwan
    Replies
    2
    Views
    691

    BMS Estimation

    Iam doing a bms estimation for one project , in that there is plate-to-plate heat exchanger ( quantity -10 ) the client has not given any schematic diagram for that ? so based on general standard's...
  36. Thread: kmc programming

    by safwan
    Replies
    15
    Views
    2,679

    I had work on both softwares......Bacstage and...

    I had work on both softwares......Bacstage and Total control.I have help files of both softwares.give me your email address... i will send you the help files.:cheers:
  37. Replies
    0
    Views
    383

    Andover Communication

    I had selected a b3851 & xPDI8 for standalone ahu ? my concern is how iam gonna do commissioning ? Is ROMAIO2 is better for communication tool ?
    Or Is there any alternative for this?
  38. Replies
    15
    Views
    1,737

    T91U-2-D-XTD PROBE/XMTR W/DISPLAY from KELE.

    T91U-2-D-XTD PROBE/XMTR W/DISPLAY from KELE.
  39. Replies
    3
    Views
    742

    Andover Continuum

    Iam doing a project where there is a 15 DGP panel's at certain floors and routers for all DGP's is setup at single place,I want to do commissioning of DGP as standalone without using router ? Is...
  40. Replies
    1
    Views
    1,067

    Andover continuum Programming problem

    i have a problem when executing pumpseq program

    i am getting the following error

    " used an incorrect argument in the function"
  41. Replies
    3
    Views
    3,604

    Programming of controls

    Hello Guys I have a Problem regarding the programming of the chillers & pumps, Iam doing programming in EC- Programming tool of distech controls, as Iam new to this....i tried to do find programming...
  42. Replies
    1
    Views
    484

    Programming for Two Pumps.

    iam doing a project, which has three chiller pumps, at a time 2 pumps should run and one should be on stand by, after 24 hours change by will switch the motors from running? how should i program it?...
  43. Thread: Trends

    by safwan
    Replies
    2
    Views
    651

    Trends

    I Know "Trends" is a graphical representation of data, as per my knowledge i know only two trends, PC Trend and Controller Based Trend ? Is it True? if yes what is the diffrence between them? if not...
  44. Thread: Simulator

    by safwan
    Replies
    4
    Views
    1,023

    Simulator

    Hello Friends,

    Is there any simulator software for controls of any manufacturer? I need one for me to practice ?
  45. Thread: Languages.

    by safwan
    Replies
    2
    Views
    418

    Languages.

    How Many type of control languages are there in control feild,Including Industrial Automation???
  46. Replies
    5
    Views
    549

    my question is what should the minimum pressure...

    my question is what should the minimum pressure drop for a butterfly valve in liquid application(water)?
  47. Replies
    5
    Views
    549

    Valve Pressure Drop

    What should be the minimum pressure drop of the Valve?
  48. Thread: return fan

    by safwan
    Replies
    5
    Views
    2,128

    Thanks I got a Point from Ur Answer:cheers:.

    Thanks I got a Point from Ur Answer:cheers:.
  49. Thread: return fan

    by safwan
    Replies
    5
    Views
    2,128

    return fan

    Why do we use return fan in AHU? Even though it is return duct for exhaust?
  50. Replies
    29
    Views
    4,800

    Thanks dude.......Its like a manuscript.....Old...

    Thanks dude.......Its like a manuscript.....Old is Gold.:grin2:
Results 1 to 50 of 63
Page 1 of 2 1 2

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event