Search:

Type: Posts; User: KevinAdv

Page 1 of 9 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    15
    Views
    863

    H10 I had a slr2k7 what a piece of junk I...

    H10

    I had a slr2k7 what a piece of junk
    I could turn on the h10 and leave it n the van and have a better chance of finding the leak
  2. Replies
    10
    Views
    515

    Just fixed a 58gs yesterday 26 years old ...

    Just fixed a 58gs yesterday 26 years old

    Recommended a new furnace no dice

    Finally got it running good after 2 hours of cleaning and adjusting
  3. Replies
    42
    Views
    2,547

    I use a turbo torch for plumbing i hate mapp &...

    I use a turbo torch for plumbing i hate mapp & propane cannot imagine brazing with one

    I hate turbo torch for brazing too only use it when i dont want lug around the oxy acet rig
  4. Caps & low on refrigerant I will offer repair...

    Caps & low on refrigerant

    I will offer repair of the leak if its possible to fix most are in the coils and are from multiple spots i have the h10 so finding leaks is usually fast

    Changing just...
  5. no problem

    no problem
  6. Replies
    4
    Views
    1,635

    I think there pretty easy to work on it took me...

    I think there pretty easy to work on it took me 10 mins to change an inducer on one

    The Colemans I hate are the old standing pilots its a big pain to light the pilot since its hard to see through...
  7. Replies
    15
    Views
    753

    Im gonna guess overcharged most lennoxs dont have...

    Im gonna guess overcharged most lennoxs dont have an accumulator so the correct charge is critical

    Also as said the gauge readings are wrong you need true suction port
  8. They are certainly not the worst but I try to...

    They are certainly not the worst but I try to stay away from them and they seem to have a shorter life because of lower quality components and the hack installs
  9. Replies
    8
    Views
    817

    Mine do not ever get used after the first two...

    Mine do not ever get used after the first two weeks and the novelty factor wore off there are some types of work they probably make since but the I manifold has not told me anything I didn't already...
  10. Replies
    25
    Views
    5,505

    We have installed three two hp's one with a xc95m...

    We have installed three two hp's one with a xc95m furnace awesome systems

    I plan on installing one on my house within the next year
  11. Replies
    6
    Views
    456

    still sounds low most residential txv's are...

    still sounds low

    most residential txv's are not adjustable
  12. Replies
    7
    Views
    765

    Trane using Micro Channel coils

    Installed a 3 ton Trane gas pack today and the evaporator coil was a microchannel

    Have to see how this works out

    I know York cant make one to save their life
  13. Last week sucked this week sucked and next week...

    Last week sucked this week sucked and next week will probably suck:gah:

    bunch of warranty txv's, coil's new equipment being DOA and a bunch of difficult service calls
  14. Replies
    21
    Views
    1,966

    The most reliable furnace is a natural draft...

    The most reliable furnace is a natural draft standing pilot with a fan limit
  15. Replies
    21
    Views
    1,966

    ding ding ding I got a call last week "We...

    ding ding ding

    I got a call last week "We probably need a quote on a new unit this one is old and shot" it was a trane heat pump from 1993 replaced the blown run cap amp draws and refrigerant...
  16. Replies
    7
    Views
    2,573

    Installed a Trane air handler it was in the...

    Installed a Trane air handler it was in the winter so I ran it in heat runs for about 2 mins then cuts out on high pressure took me an hour to figure the blower was spinning backwards the wiring to...
  17. Replies
    40
    Views
    4,564

    I rent a house and first time i turned on the a/c...

    I rent a house and first time i turned on the a/c the unit was basically empty called the land lord and the home warranty came out and added leak seal i think it actually worked but the compressor...
  18. Thread: 410

    by KevinAdv
    Replies
    67
    Views
    3,553

    410a is fine its the manufacturers building junk...

    410a is fine its the manufacturers building junk thats the problem
  19. Replies
    79
    Views
    10,260

    I have replaced 3 this week 2 were package units,...

    I have replaced 3 this week 2 were package units, 1 day & night and 1 trane the trane was a pita never want to do that again

    1 Trane split I pulled the bulb let it hang in the attic took a week to...
  20. Replies
    103
    Views
    26,304

    I have started buying Amrad caps to keep on the...

    I have started buying Amrad caps to keep on the truck I'm in the process of using up all the mars Caps and I am switchting to turbo 200 minis for my smaller caps
  21. Replies
    103
    Views
    26,304

    some older houses here have three phase power...

    some older houses here have three phase power eliminate the run cap eliminate it from failing
  22. Thread: XV20i

    by KevinAdv
    Replies
    22
    Views
    3,420

    I have had quite a few I have had to rip the guts...

    I have had quite a few I have had to rip the guts out of to make the system work correctly
  23. 68 when its 110 outside not gonna happen

    68 when its 110 outside not gonna happen
  24. Replies
    1,326
    Views
    192,821

    Finally got an I manifold I used it on my own...

    Finally got an I manifold I used it on my own system today seems pretty neat Will start using it tomorrow on customers systems

    Not sure if I will use it on every job or keep using the Testo 550's...
  25. Replies
    19
    Views
    1,323

    I keep 1/3 hp 1075 1/4 hp 1075 1/3 to 1/6...

    I keep

    1/3 hp 1075
    1/4 hp 1075
    1/3 to 1/6 1075 rescue
    1/3 to 1/6 825 rescue

    I almost never get an oem motor unless its under warranty if the units 15 years old its not gonna last much...
  26. Replies
    22
    Views
    1,671

    Why go to the call if you don't try to make the...

    Why go to the call if you don't try to make the repair
  27. I have gotten lunch several times I usually get...

    I have gotten lunch several times I usually get $20-50 a week in tips and one time got a $100 tip each for me and my coworker I tried to give it back and she was insistent i take it
  28. Replies
    16
    Views
    1,505

    I have the tech mindset but even if I bid a job...

    I have the tech mindset but even if I bid a job for a third guy or two days my boss wants it done in one day.

    to do a proper start up on most system it takes about two hours
  29. Replies
    15
    Views
    2,140

    We have some systems running as low as .20 tesp ...

    We have some systems running as low as .20 tesp

    On a retrofit .40-.60 is more the norm after duct modifications
  30. Replies
    70
    Views
    11,399

    Would it kill them to male the Cabinets out of...

    Would it kill them to male the Cabinets out of something a littler thicker than what seem like 30 gauge metal

    I have installed some Goodman units and I still don't like them Day & Night is my go...
  31. Thread: Imanifold?

    by KevinAdv
    Replies
    5
    Views
    616

    x2

    x2
  32. Thread: New House

    by KevinAdv
    Replies
    30
    Views
    6,315

    I have never seen a tract house with a decently...

    I have never seen a tract house with a decently installed system unless it was replaced
  33. Replies
    11
    Views
    2,316

    Thats fine and I understand if it was standard or...

    Thats fine and I understand if it was standard or code here I would do it

    but because it isn't here and I don't doesn't mean I'm a hack
  34. Replies
    11
    Views
    2,316

    I have never seen a furnace with hard piped gas...

    I have never seen a furnace with hard piped gas line or with power ran in conduit to the furnace in this state.

    But if I showed a picture of a furnace I installed without those done I would get a...
  35. Replies
    11
    Views
    2,316

    Exactly I won't post again I do very good work...

    Exactly I won't post again I do very good work but you can nit pick anything and will the customer pay twice as much for everything to look absolutely perfect even it doesn't affect performance
  36. I would welcome it If i decided to leave my...

    I would welcome it If i decided to leave my current company I don't want to end up finding out the new company is worse
  37. Replies
    43
    Views
    7,133

    I have been less than impressed with the...

    I have been less than impressed with the electricians I have dealt with some are downright dumb kind of scary that they play with electricity
  38. Replies
    46
    Views
    7,912

    I think Rheem or Ruud I like the spark ignition...

    I think Rheem or Ruud I like the spark ignition as opposed to HSI

    Definitely one that is not 90% as well
  39. the multizone mini splits efficiency is nothing...

    the multizone mini splits efficiency is nothing to write home about especially EER

    A trane xv18 or 20 or Carrier Green Speed give you the variable capacity of a mini split in a more efficent...
  40. Replies
    36
    Views
    3,359

    I have never heard of doing it if the air handler...

    I have never heard of doing it if the air handler is above the condenser, I have done it vice versa.

    If they are going to use such a large suction line the velocity in the pipe may be too low to...
  41. Replies
    36
    Views
    3,359

    Goodman must be nuts no 410A system 5ton or under...

    Goodman must be nuts no 410A system 5ton or under needs 1" 1/8
  42. Replies
    39
    Views
    5,990

    I went to RSI always scored 90+ on tests and was...

    I went to RSI always scored 90+ on tests and was in no way prepared for the field the first two years were brutal there is not a whole lot of hands on at RSI and they make you learn solar and...
  43. Replies
    19
    Views
    2,632

    I prefer the oxy acytelene but I do use the turbo...

    I prefer the oxy acytelene but I do use the turbo sometimes in attics or on a roof if I don't feel like hauling the oxy rig around
  44. Replies
    29
    Views
    3,663

    I believe the Nest also doesn't click

    I believe the Nest also doesn't click
  45. Replies
    839
    Views
    189,790

    Not a service call but a estimate lady is nuts...

    Not a service call but a estimate lady is nuts she wants a mini split to cool a room I start looking at things she says what are you doing I have to see where to run the refrigerant lines and put the...
  46. Thread: Cooling Off

    by KevinAdv
    Replies
    60
    Views
    8,903

    I always put heatpumps in heat in the summer to...

    I always put heatpumps in heat in the summer to defrost the coil They really put out the heat when its 110 degrees :grin2:
  47. Replies
    24
    Views
    2,613

    I know I was joking although if it has a/c...

    I know I was joking although if it has a/c upgrading to a heat pump makes a ton of sense
  48. Replies
    24
    Views
    2,613

    but a new one is more efficient :grin2:

    but a new one is more efficient :grin2:
  49. Replies
    6
    Views
    924

    the 9 in the condenser model # is for 19 seer it...

    the 9 in the condenser model # is for 19 seer it is a XL19i
  50. Replies
    12
    Views
    1,552

    I had a gam5 do the same thing one time although...

    I had a gam5 do the same thing one time although most we do don't have any heat kits I wonder if a blower off delay would help

    getting that static down should help as well I don't think the supply...
Results 1 to 50 of 450
Page 1 of 9 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Comfortech 365