Search:
Type: Posts; User: TommyC11
Search: Search took 0.00 seconds.
-
03-08-2013, 03:24 PM
Thread: Niagara PX help
by TommyC11- Replies
- 11
- Views
- 1,075
no problem... I am sure that someone told me how...
no problem... I am sure that someone told me how to do it many moons ago as well !!!
Sharing knowledge is key, or it will be lost !!!
have a great weekend !!
TommyC -
03-08-2013, 07:34 AM
Thread: Niagara PX help
by TommyC11- Replies
- 11
- Views
- 1,075
vaultein, use a bound label binding as below......
vaultein,
use a bound label binding as below...
station:|slot:/Services/WeatherService/WeatherReport/day2
in the "text" field of the bound label, use the following...
%displayName%
It will... -
03-07-2013, 06:34 AM
- Replies
- 14
- Views
- 579
S2sam, Not sure that we could qualify as a beta...
S2sam,
Not sure that we could qualify as a beta test site but we do support multiple N2 bus customers. Please give us a sneak peek as soon as you can !!!
Thanks... -
10-26-2012, 05:52 PM
Thread: BACnet TEC Thermostats and busy time
by TommyC11- Replies
- 26
- Views
- 2,107
I was reading through this post and wondered why...
I was reading through this post and wondered why the video link is no longer available? It sounds as if it was very helpful and I would like to learn more about tuning policies.
Can anyone re-post... -
08-30-2012, 10:51 PM
Thread: JACE and AAM NB-VAV objects issue
by TommyC11- Replies
- 4
- Views
- 428
davem, I do have the controller documentation,...
davem,
I do have the controller documentation, and will actually be going to that site tomorrow. I will attempt again and let you know what I find out.
Thanks.... Tommy C -
08-30-2012, 01:30 PM
Thread: JACE and AAM NB-VAV objects issue
by TommyC11- Replies
- 4
- Views
- 428
JACE and AAM NB-VAV objects issue
Good afternoon,
I hope my explanation here can make sense, but if not, please let me know what information I have left out. I am attempting to map in NB-VAV controller objects into a JACE for a... -
08-29-2012, 02:48 PM
Thread: N30 and System help
by TommyC11- Replies
- 7
- Views
- 577
Power_Pusher, If I understand you correctly from...
Power_Pusher,
If I understand you correctly from the info you posted, I am not even sure how you can "read the DX9100 program" by connecting your PC serial port to the back of the DX9100. The only... -
08-29-2012, 06:51 AM
Thread: Running CCT and PCT w/ XP Mode
by TommyC11- Replies
- 7
- Views
- 387
That makes sense, as I am sure JCI wants to...
That makes sense, as I am sure JCI wants to protect their side of the business from the distributor side. I never thought about moving custom modules around though, as there appear to be plenty...
-
08-28-2012, 07:58 PM
Thread: floating ground ?
by TommyC11- Replies
- 14
- Views
- 1,532
most control manufacturers want a grounded...
most control manufacturers want a grounded secondary. JCI for example, is adamant that you DO NOT ground the secondary side a they claim the floating ground principle.
I agree with all the... -
08-28-2012, 07:54 PM
Thread: Running CCT and PCT w/ XP Mode
by TommyC11- Replies
- 7
- Views
- 387
Not sure why you would want to run both. From...
Not sure why you would want to run both. From what I have heard, PCT can go into CCT programs, just not the other way around. I installed PCT in XP mode, along with all SQL requirements and it runs...
-
08-28-2012, 07:52 PM
Thread: HVAC Pro 8.08 B patch
by TommyC11- Replies
- 21
- Views
- 2,918
I have run 8.08b on XP just fine for years. For...
I have run 8.08b on XP just fine for years. For Windows 7 however, I had to install in XP mode to get it to work.
-
08-28-2012, 07:45 PM
Thread: Factory startup
by TommyC11- Replies
- 6
- Views
- 501
IMHO, most of the startups we see are completed...
IMHO, most of the startups we see are completed by the Sales Engineer because the real startup guy is overbooked by a factor of 3 at least !!
-
08-28-2012, 12:09 PM
Thread: JCI/Metasys System N2
by TommyC11- Replies
- 49
- Views
- 5,065
apprentice3... if you want some assistance,...
apprentice3... if you want some assistance, please send me a private message. I am in the Columbus, OH area and can help you with whatever you need... figuring out what you have, where you need to...
-
04-11-2012, 06:41 AM
Thread: BACnet display monitor
by TommyC11- Replies
- 6
- Views
- 594
Orion242....No, they have not been purchased and...
Orion242....No, they have not been purchased and the customer understands the cost. Given the area that they want them displayed in (all of their engineers are right there) they want the size but...
-
04-10-2012, 12:53 PM
Thread: BACnet display monitor
by TommyC11- Replies
- 6
- Views
- 594
BACnet display monitor
Hello all,
We have an industrial customer that is interested in setting up 3 or 4 large display monitors in their operations area. These displays would have independent static displays (graphic or... -
04-10-2012, 11:51 AM
Thread: Johnson Controls DX-9100
by TommyC11- Replies
- 49
- Views
- 5,123
Sam, I did not see an email address on your...
Sam, I did not see an email address on your profile, just web site information. If you could please email me directly, I am interested in this solution and other insights you may have. We do support...
-
04-10-2012, 06:55 AM
Thread: Johnson Controls DX-9100
by TommyC11- Replies
- 49
- Views
- 5,123
Sam, I appreciate the feedback. I have checked...
Sam,
I appreciate the feedback. I have checked the drivers and they seem up to date. The only weird part I see is that the XP mode driver is obviously different than the driver that is resident in... -
04-08-2012, 07:23 PM
Thread: Johnson Controls DX-9100
by TommyC11- Replies
- 49
- Views
- 5,123
I am running a similar setup (Edgeport/1 USB...
I am running a similar setup (Edgeport/1 USB adapter) as explained but have Windows 7, 64 bit installed. This requires a Windows XP mode environment to run the GX software. My issue is that almost...
-
04-08-2012, 07:15 PM
Thread: Controls Manufacturer Visio Shapes
by TommyC11- Replies
- 8
- Views
- 1,210
Is there any chance I can get in on that mind...
Is there any chance I can get in on that mind sharing? I would appreciate it greatly. My address is already in my profile...
Thanks, Tom -
01-06-2012, 06:37 AM
Thread: Need to print new labels for DX-9100
by TommyC11- Replies
- 6
- Views
- 445
Thanks exwtk... I appreciate it !! And it looks...
Thanks exwtk... I appreciate it !! And it looks nicely done too !!
-
01-05-2012, 02:20 PM
Thread: Johnson Visio Stencils
by TommyC11- Replies
- 25
- Views
- 2,548
Controls1982, I would be interested in seeing...
Controls1982,
I would be interested in seeing what you have for stencils as well. My email is in my profile if you would be so kind.
Thanks !! -
01-05-2012, 02:14 PM
Thread: Need to print new labels for DX-9100
by TommyC11- Replies
- 6
- Views
- 445
I would be interested in that file as well. can I...
I would be interested in that file as well. can I jump on the bandwagon ?
My email is in my profile as well.
Thanks !!
Results 1 to 22 of 22