  1. Replies
    22
    Views
    763

    Replaced the ten pistons and drier today, fun job...

    Replaced the ten pistons and drier today, fun job had to crawl down inside thru condenser fan hole and remove each one and braze the ten new one in system was working fine when I left.:cheers:
  2. Replies
    16
    Views
    1,478

    nice oil traps

    nice oil traps
  3. Replies
    15
    Views
    1,792

    I went to one like that just got back in my truck...

    I went to one like that just got back in my truck and went to the next one told them they needed a carpenter.
  4. Replies
    22
    Views
    763

    vtp99 you ever changed any of these? I may see if...

    vtp99 you ever changed any of these? I may see if I can talk into new system the heat exchanger isn't looking to good either.
  5. Replies
    22
    Views
    763

    it has like 80 super heat and 10 sub cooling...

    it has like 80 super heat and 10 sub cooling weighed charge in then added 2 lbs more still didn't go up. I know it has a restriction was just wanting to know where expansion device is and now I...
  6. Replies
    22
    Views
    763

    it has one danfoss scroll and one Copeland recip

    it has one danfoss scroll and one Copeland recip
  7. Replies
    22
    Views
    763

    replaced drier, system was overcharged, and full...

    replaced drier, system was overcharged, and full of air, somebody replaced scroll compressor with a reciprocating compressor.
  8. Replies
    22
    Views
    763

    Thanks for instruction sheet.

    Thanks for instruction sheet.
  9. Replies
    22
    Views
    763

    700911

    700911
  10. Replies
    22
    Views
    763

    I belive it is after will try to post picture.

    I belive it is after will try to post picture.
  11. Replies
    22
    Views
    763

    There is frost at each one of them anyway to...

    There is frost at each one of them anyway to clean or replace them.
  12. Replies
    22
    Views
    763

    Carrier 48TME012---501

    Worked on this unit today I be think it has a restriction in it already replaced drier and weighed charge back in suction pressure only 14 . I don't see any expansion valve or piston. Liquid line...
  13. Replies
    24
    Views
    1,179

    I leave the upstairs windows open I like fresh...

    I leave the upstairs windows open I like fresh air why can't I get my house below 80.
  14. Thread: Roof Curbs

    by coyote
    Replies
    4
    Views
    380

    Roof Curbs

    Do you guys buy roof curbs from the people you buy furnaces from or is there somebody who sales them direct to contractors same with curb adapters.
  15. Replies
    3
    Views
    609

    ICP Inverter units

    Has anybody sold any of the ICP 18 to 19 SEER units with inverter? What did you think about them?
  16. Replies
    5
    Views
    381

    I put a piece of paper in it to get through today

    I put a piece of paper in it to get through today
  17. Replies
    5
    Views
    381

    uniweld flow meter pop off

    I blew the 50 lb pop off on my uniweld nitrogen flow meter today anybody know where I can get the small disc that blows out when it is over 50lb. It looks like a small disc of tin foil, I e-mailed...
  18. Replies
    62
    Views
    3,816

    I thought R407C requires POE oil .

    I thought R407C requires POE oil .
  19. Replies
    10
    Views
    1,071

    Have read post about leak detectors for R410A now...

    Have read post about leak detectors for R410A now more confused than ever. Narrowed it down to H10 -D-tek or fieldpiece srl2. Opinions on these 3.
  20. Replies
    17
    Views
    1,544

    lytning was any of the 2 times on R410A I need a...

    lytning was any of the 2 times on R410A I need a new R410A leak detector and can't decide what to get.
  21. Replies
    10
    Views
    1,071

    My D Tek was the infared one but was older than 4...

    My D Tek was the infared one but was older than 4 or 5 years got it when they first came out couldn't find a leak with it. Sent it to a repair place3 or four years ago the guy said it was recalled...
  22. Replies
    10
    Views
    1,071

    Good R410A leak Detector

    My Inficon Detect-Select burned up and I have been looking for a good R410A leak detector I have searched this site and others and now I'm more confused than before. I am thinking about the H 10 or...
  23. Replies
    15
    Views
    1,233

    Everyone know Coyotes can't catch road runners...

    Everyone know Coyotes can't catch road runners but we can Racoons
  24. Replies
    15
    Views
    1,233

    Your right about that basement it is a scary...

    Your right about that basement it is a scary place to go, has standing water and a sailboat in it wish I would have got a picture of boat in basement.
  25. Replies
    15
    Views
    1,233

    Service call + I get to keep the coon.

    Service call + I get to keep the coon.
  26. Replies
    15
    Views
    1,233

    Forgot to take my dog so he could tree him.

    Forgot to take my dog so he could tree him.
  27. Replies
    15
    Views
    1,233

    Noise in Furnace

    Lady said she thought blower was making noise.658351
  28. Thread: it's never easy

    by coyote
    Replies
    1
    Views
    447

    it's never easy

    Had to put a inducer motor relay on today motor stayed on all time . Put relay on it started buzzing after half hour chasing wires and switches I found it the screw was loose on t-87 t stat. I guess...
  29. Replies
    40
    Views
    2,539

    I have windows 10 on new computer but I can't get...

    I have windows 10 on new computer but I can't get my e-mail to work. I have roadrunner e-mail and I can't make it work, every time I try it changes the password from 8 characters to 18.
  30. Replies
    1
    Views
    352

    Bacharach Insight

    I got my CA today I have a question about when testing a 90+ 2 pipe system. Do you have to have another temp probe in the intake pipe?
  31. Replies
    3
    Views
    388

    Would slow opening work in place of step?

    Would slow opening work in place of step?
  32. Replies
    3
    Views
    388

    A very old Sears hot air furnace don't have...

    A very old Sears hot air furnace don't have model with me, owner wants to get thru winter house is being torn down next year. Gas company says valve leaks thru.
  33. Replies
    3
    Views
    388

    Honeywell gas valve v8280

    Do any of you know the specs for this gas valve, is it slow opening, step opening, or standard opening? Honeywell V8280 C10352
    Thanks in advance.
  34. Thread: Hilti drills

    by coyote
    Replies
    5
    Views
    1,158

    I have one don't remember model # use it with...

    I have one don't remember model # use it with core bits makes short work of brick and concrete walls.
  35. Replies
    11
    Views
    1,075

    If the board sh is set to 20 shouldn't sh stay...

    If the board sh is set to 20 shouldn't sh stay close to that. I saw the sh drop at one to 5 degrees.
  36. Replies
    11
    Views
    1,075

    I checked the in and out sensors and they are...

    I checked the in and out sensors and they are right. superheat is set for 20 degrees. Will change it tomorrow to 10 degrees like cover says. Saw valve say 28 % open and had 8 degree super heat.
  37. Replies
    11
    Views
    1,075

    Has a sporlan control master bilt controller...

    Has a sporlan control master bilt controller 952953 board has a date of 2012 charge is good or it wouldn't work for days if not, is a sporlan moisture indicator should be yellow or green doubt if it...
  38. Replies
    11
    Views
    1,075

    reverse cycle. Don't know who made valve. Ohms is...

    reverse cycle. Don't know who made valve. Ohms is suppose to be 90,ohms fine. Moisture indicator is not yellow or green looks black or purple.
  39. Replies
    11
    Views
    1,075

    Mac 7 mc donalds Help

    worked on McDonalds walk in freezer all day. Compressor starts going off on low pressure. Heat EEV and works for a while like it has moisture in system added Thaw Zone and new drier. Anybody have...
  40. He said coil is leaking which coil, the coil...

    He said coil is leaking which coil, the coil itself should be under warranty. I was told once outdoor coil has to have a non repairable leak for no hassle and you only get one unit.
  41. Replies
    3
    Views
    3,970

    ICP SERVICE BULLETIN

    Anybody know of a service bulletin on the rust inhibitor for ICP units. Seen one where Bryant was paying $195.00
  42. Thread: CPS-LS2

    by coyote
    Replies
    3
    Views
    887

    Decided to order one today I guess will find out...

    Decided to order one today I guess will find out for my self let you know.
  43. Thread: CPS-LS2

    by coyote
    Replies
    3
    Views
    887

    CPS-LS2

    Anybody have one of these leak detectors will it find R410A?
  44. Thread: Trane HP

    by coyote
    Replies
    3
    Views
    496

    Thank You.

    Thank You.
  45. Thread: Trane HP

    by coyote
    Replies
    3
    Views
    496

    Trane HP

    Found a 6H2042A100A0 heat pump wit a TXC36C4HPCO indoor coil. I thought it was a 3.5 ton heat pump the indoor coil looks like a 3 ton, is this a match?
  46. Replies
    21
    Views
    4,010

    Tried to use mine the other day because system...

    Tried to use mine the other day because system had a short that would blow fuses every time. Thought we found short so I put in poper instead of fuses turned breaker on system smoke came out of fan...
  47. Thread: Potential Relay

    by coyote
    Replies
    5
    Views
    1,667

    Potential Relay

    Anybody know where to get a cross reference for potential relays . I had mars cross reference but couldn't find Copeland 040-0166-15
  48. Thread: Mac 7 HELP

    by coyote
    Replies
    9
    Views
    1,271

    Had freezer turned off and it warmed up turned it...

    Had freezer turned off and it warmed up turned it back on now it works just fine, I think maybe has moisture in system.
  49. Thread: Bryant txv

    by coyote
    Replies
    205
    Views
    38,360

    I heard today it is a additive added to...

    I heard today it is a additive added to compressor causing it.
  50. Thread: Mac 7 HELP

    by coyote
    Replies
    9
    Views
    1,271

    thats the one already have the book Thanks

    thats the one already have the book
    Thanks
Results 1 to 50 of 203