Search:

Type: Posts; User: rayr

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    13
    Views
    1,521

    Check Harris alloy page and you will be surprised...

    Check Harris alloy page and you will be surprised at the tensil strength of Staybrite 8 compared to staysilv 15
  2. Replies
    17
    Views
    1,248

    X2

    X2
  3. Replies
    8
    Views
    399

    United Refrigeration. You can calibrate them,...

    United Refrigeration. You can calibrate them, just have to figure it out. We do it all the time.
  4. 35-40 sh at evap means it is starved. Solenoid...

    35-40 sh at evap means it is starved. Solenoid installed proper flow direction? TD across LL drier??
    Check if x valve is opening and closing with temp change on remote bulb?? Correct X valve? And...
  5. What moron came up with that bright idea????

    What moron came up with that bright idea????
  6. Replies
    44
    Views
    2,347

    X2. You can have 0 superheat but not negative...

    X2. You can have 0 superheat but not negative superheat.
  7. Replies
    44
    Views
    2,347

    LOL. Got it.:whistle:

    LOL. Got it.:whistle:
  8. Replies
    44
    Views
    2,347

    In the first place you do not "Read" superheat....

    In the first place you do not "Read" superheat. You read temp, pressures, (SST) and then calculate the superheat. You cannot have "Negative superheat". CDave would have a field day with this. ...
  9. Thread: Fluke 902

    by rayr
    Replies
    18
    Views
    1,353

    The 325 does not have a micro amps option.

    The 325 does not have a micro amps option.
  10. Replies
    20
    Views
    2,991

    I am trying to figure out how a failed X valve...

    I am trying to figure out how a failed X valve can cause the ID and OD coils to leak??????
  11. Thread: Tube benders???

    by rayr
    Replies
    36
    Views
    3,063

    I have used the Yellow Jacket. Not much good to...

    I have used the Yellow Jacket. Not much good to say about 7/8 tubing. I have a REMS. Perfect bend first time, perfect bend every time. Had it about 10 years. Costs more, but does it right.
  12. Replies
    56
    Views
    3,671

    Those are "Weapons".

    Those are "Weapons".
  13. Autozone!

    Autozone!
  14. Replies
    56
    Views
    3,671

    Do not think this applies to fan blades. Shaft...

    Do not think this applies to fan blades. Shaft can go in either end. Using the hub as a reference for rotation will not work either. Hub and be on either side, depending on the manufacturer. I like...
  15. Replies
    20
    Views
    3,753

    Dumb, but trap is code here no matter if it is...

    Dumb, but trap is code here no matter if it is negative or positive side of ariflow.
  16. Thread: Relay in a Box

    by rayr
    Replies
    15
    Views
    3,027

    I cut mine on Weathertrons a long time ago. :)

    I cut mine on Weathertrons a long time ago. :)
  17. Let him have the Chinese Restaurants Terry it...

    Let him have the Chinese Restaurants Terry it will be a better learning experience then school !

    Light buld Wattage ?


    3.4 Btus per watt.
  18. Replies
    10
    Views
    885

    Now that is being creative. Adapt and overcome.

    Now that is being creative. Adapt and overcome.
  19. Replies
    11
    Views
    992

    We (I) do kitchen refrigeration and exhaust...

    We (I) do kitchen refrigeration and exhaust hoods. Biggest one we installed was 30' with 9000 cfm ex and 7200 mua. Am in process of installing a 20 and 8 ft hood in a new restaurant. 7200 ex. Mua...
  20. Replies
    26
    Views
    2,871

    I have a Fluke 902 and always have an analog...

    I have a Fluke 902 and always have an analog backup.
  21. Replies
    18
    Views
    3,317

    Very nice, clean work. What is that Dewalt thingy...

    Very nice, clean work. What is that Dewalt thingy in the second pic, generator, radio??
  22. Replies
    3
    Views
    445

    First order of the day would be to know how many...

    First order of the day would be to know how many btu's are required. How much insulation, vapor barrier, is it out in the blazing sun, and design conditions??? 5,000 may be ok, but then again maybe...
  23. Replies
    58
    Views
    3,545

    Probably the best info you can get right now is...

    Probably the best info you can get right now is to spend a few bux and get someone over there that knows REFRIGERATION. Have them check out the install and charge it. Apparently you are in over your...
  24. Replies
    58
    Views
    3,545

    X2 Exactly:)

    X2 Exactly:)
  25. Replies
    58
    Views
    3,545

    Somewhat of a waste of time checking subcooling...

    Somewhat of a waste of time checking subcooling with a receiver in place, don't you think?
  26. Replies
    53
    Views
    6,167

    We make our own curb adaptors. Usuall about...

    We make our own curb adaptors. Usuall about $1,000.00 to buy em.
  27. Thread: New 92%er

    by rayr
    Replies
    17
    Views
    2,642

    Gas flex going through cabinet,,,,,that is a big...

    Gas flex going through cabinet,,,,,that is a big no no.
  28. Replies
    59
    Views
    6,866

    Most do not. I install one on every new install....

    Most do not. I install one on every new install. The last thing I need are compressors cycling on the internal overload and cooking the POE. Doubtful that this site will see it's demise due to a few...
  29. Thread: Recent install

    by rayr
    Replies
    19
    Views
    2,042

    Inside of "B" vent is aluminum.

    Inside of "B" vent is aluminum.
  30. Replies
    59
    Views
    6,866

    If you knew the NEC, you would know that the...

    If you knew the NEC, you would know that the raceway must be secured within 12 inches of the disconnect
  31. Thread: Magnafish

    by rayr
    Replies
    4
    Views
    778

    I use fishsticks with no problem.

    I use fishsticks with no problem.
  32. Replies
    53
    Views
    3,063

    My error thought I was reading the freezer thread.

    My error thought I was reading the freezer thread.
  33. Replies
    53
    Views
    3,063

    40 lbs suction on a 404 freezer at set point????...

    40 lbs suction on a 404 freezer at set point???? That does not sound right....
  34. Replies
    9
    Views
    667

    x2. In 1979 (or there abouts) there was a...

    x2. In 1979 (or there abouts) there was a shortage of R-22 and the only thing I could ge was Dupont with Dytel in it.......I hated it.
  35. Thread: another tool bag

    by rayr
    Replies
    9
    Views
    1,315

    That bag really deserves a "Fluke" in place of...

    That bag really deserves a "Fluke" in place of that Fieldpiece
  36. Replies
    71
    Views
    5,318

    Must be really efficient to, huh?:whistle:

    Must be really efficient to, huh?:whistle:
  37. Replies
    71
    Views
    5,318

    That will prob outlive any newer units. Those...

    That will prob outlive any newer units. Those commercial units are NOT cheap.
  38. Thread: My Wife's Friend

    by rayr
    Replies
    8
    Views
    2,093

    Most times,, it is safer to take the money. :)

    Most times,, it is safer to take the money. :)
  39. When the frost is within 6 inches of the...

    When the frost is within 6 inches of the compressor when it reaches setpoint, it is just about right. Old school stuff. Never failed me in a pinch.
  40. In my experience, high side pressure measurements...

    In my experience, high side pressure measurements are not advisable due to the very small amount of refrigerant in the system. OMO.
  41. Replies
    8
    Views
    1,035

    United has a new one on the shelf. Jumper with...

    United has a new one on the shelf. Jumper with small magnet on each end. Works well on metal screw terminals. Not brass of course.
  42. Just what we need, another flavor of refrigerant...

    Just what we need, another flavor of refrigerant to carry around.
    :gah:
  43. Replies
    5
    Views
    990

    can that be used on an extension ladder?

    can that be used on an extension ladder?
  44. Thread: Made me laugh

    by rayr
    Replies
    12
    Views
    3,771

    We will be installing one in March. It has...

    We will be installing one in March. It has modulating gas valve to maintain 70 deg air temp. Will be 13 tons of air conditioning. Will have VFD for 73000 exhaust fan and MUA unit. This will service...
  45. Replies
    20
    Views
    4,470

    Third wolrd countries. Seen some insane stuff...

    Third wolrd countries. Seen some insane stuff work wise stuff in Caracus. Never want to go back.
  46. Replies
    16
    Views
    1,444

    CDave would have a field day with this. There is...

    CDave would have a field day with this. There is no such thing as "Negative Superheat". You may have negative temperature and/or negative pressure but not negagtive superheat. Best re-check.
  47. Replies
    24
    Views
    3,317

    If it were mine and I was using 134-a, I would...

    If it were mine and I was using 134-a, I would put a small receiver on it along with an expansion valve. POE and cap tubes are poblematic at times if the compressor over heats, especially if...
  48. Replies
    11
    Views
    998

    I bought my first one in 1965 and it was made by...

    I bought my first one in 1965 and it was made by GE for a very long time.
  49. Thread: Nice return room

    by rayr
    Replies
    9
    Views
    1,705

    Don't suppose they have CO detectors?

    Don't suppose they have CO detectors?
  50. Replies
    13
    Views
    1,322

    LOL

    LOL
Results 1 to 50 of 1000