Search:

Type: Posts; User: klrogers

Page 1 of 20 1 2 3 4

Search: Search took 0.05 seconds.

  1. Replies
    4
    Views
    163

    Here is a reasonable discussion on 2 wire vs 3...

    Here is a reasonable discussion on 2 wire vs 3 wire

    http://www.chipkin.com/rs485-cables-why-you-need-3-wires-for-2-two-wire-rs485/
  2. Try changing the service type of the binding to...

    Try changing the service type of the binding to Reliable or even Critical, sometime Trane will not process Standard binding correctly.

    Kevin
  3. Replies
    7
    Views
    266

    +1 on the VMWare over Virtual PC

    +1 on the VMWare over Virtual PC
  4. Thread: Jace Serial

    by klrogers
    Replies
    2
    Views
    225

    platform services/licensePlatformService/view...

    platform services/licensePlatformService/view license or just on platform services container plugin
  5. Replies
    9
    Views
    407

    Measuring volume of sewer water

    We have a customer that take the environmental responsibility issue very much to heart. We already measure electrical consumption and domestic water incoming volume (three separate water meters...
  6. 609981 Hope this helps you.

    609981

    Hope this helps you.
  7. Alerton typically uses one of the following: ...

    Alerton typically uses one of the following:

    10K type 2
    10K type 3
    or 3K
  8. Replies
    4
    Views
    415

    Having read the post concerned I don't see...

    Having read the post concerned I don't see anything that can not be public so here it is.

    This was posted recently on the Honeywell Forums, by a Honeywell employee. Might be of interest.

    ...
  9. Replies
    4
    Views
    415

    That is because the post is in the professionals...

    That is because the post is in the professionals section of the forum.
  10. +1

    +1
  11. Replies
    17
    Views
    746

    Still got a Simpson 260 and occasionally use it...

    Still got a Simpson 260 and occasionally use it for bench work, don't like balancing ot on top of a step ladder for field work anymore.

    Here a pic of one for the youngsters who do not know what we...
  12. Replies
    2
    Views
    218

    The way I do this is by using a bound label with...

    The way I do this is by using a bound label with a hyperlink rather than a button object, the bound label allows for easy indication on status by both color and blink.

    Kevin
  13. Replies
    40
    Views
    2,554

    Obviously someone who has swallowed the ASHRAE...

    Obviously someone who has swallowed the ASHRAE propaganda pills that make people believe BACNet is the only "open" protocol.

    Kevin
  14. Replies
    1
    Views
    255

    York and BacNET together is not always a good...

    York and BacNET together is not always a good combination, guess it depends on the translator.

    See this post. ...
  15. Thread: FOXS in AX

    by klrogers
    Replies
    15
    Views
    687

    Maybe this will help, or add to the confusion,...

    Maybe this will help, or add to the confusion, both 3.6 & 3.7 shows Foxs under Local station, but only 3.6 has a setpoint editor under Fox Service to change Foxs port.

    3.6
    596411

    3.7
    596421
  16. Replies
    10
    Views
    697

    That is indeed correct, however you can not use...

    That is indeed correct, however you can not use all their productivity enhancing (auto graphic generation) tools if it is not a Distech Jace, not a big deal, just a way from them to enhance the...
  17. Replies
    17
    Views
    3,634

    See "sticky" post at top

    See "sticky" post at top
  18. Replies
    8
    Views
    388

    That does not look good, you have not told us...

    That does not look good, you have not told us what version on software this was running. There is a bulletin for a problem similar to this on Niagara Central for version prior to 3.5. Ask your...
  19. Replies
    8
    Views
    388

    Connect to the shell with your null modem cable...

    Connect to the shell with your null modem cable and capture the output, let us see the capture and chances are someone will be able to advise you. Sounds like you might need to do a clean dist. file...
  20. Replies
    6
    Views
    303

    Sorry don't know about Honeywell WB always used...

    Sorry don't know about Honeywell WB always used Vykon.
  21. Replies
    6
    Views
    303

    If you can get access to the VykonPro Utilities...

    If you can get access to the VykonPro Utilities jar there are some BatchAdd Alarm modules in there.

    Kevin
  22. Replies
    5
    Views
    387

    I have had a Jace that was so low on heap that I...

    I have had a Jace that was so low on heap that I could not maintain a connection with WB or force a reboot from the platform application director, but was able to reboot the Jace using the very...
  23. Replies
    7
    Views
    805

    Check out "guest" user account, it is disabled in...

    Check out "guest" user account, it is disabled in newer versions due to security risks. DO NOT use it if system is connected to the internet or a large network.

    Kevin
  24. Thread: Distech Debug

    by klrogers
    Replies
    2
    Views
    306

    Don't know if this might help at all. 588681

    Don't know if this might help at all.

    588681
  25. The first question anyone will ask is it R2 or...

    The first question anyone will ask is it R2 or AX?

    But I doubt anyone will post the information on this public part of the forum.
  26. Bet someone is already working on a Brillo driver...

    Bet someone is already working on a Brillo driver for Niagara. :.02:
  27. Looks like the same problem as post#11 in this...

    Looks like the same problem as post#11 in this thread: http://hvac-talk.com/vbb/showthread.php?1749391-Facility-explorer-locks
  28. Replies
    13
    Views
    657

    You need the Java 8 version of the unlimited...

    You need the Java 8 version of the unlimited security policy files.
  29. If the user does not have permissions to view the...

    If the user does not have permissions to view the ord in the value binding of the button then the Degrade feature can either disable or hide the button.
  30. Replies
    2
    Views
    258

    Not really a controls (DDC) problem, but to help...

    Not really a controls (DDC) problem, but to help you out, the outputs from the main board have snubber circuits (look that up if you need to) this means that whenever you have no load on the wire...
  31. Replies
    13
    Views
    657

    Can you post a screenshot of the Java console as...

    Can you post a screenshot of the Java console as it is trying to load?
  32. Replies
    13
    Views
    657

    Are you saying that you upgraded the FX Jace to...

    Are you saying that you upgraded the FX Jace to Niagara version 3.8? If so you probably need to install the Java unlimited security files to ALL PC's that need to access it via a browser. I will see...
  33. Replies
    3
    Views
    546

    What version is the Jace licensed for? It looks...

    What version is the Jace licensed for? It looks like you are trying to put 3.8 on a Jace that is only licensed for 3.7.

    Kevin
  34. Replies
    5
    Views
    803

    Are you aware that Chrome disables the use of...

    Are you aware that Chrome disables the use of Java, this went into effect at Chrome version 42. You can re-enable it as follows:

    In your URL bar, enter:

    chrome://flags/#enable-npapi
    Click the...
  35. Replies
    22
    Views
    2,123

    Play the Tridium Talk presentation, gives a...

    Play the Tridium Talk presentation, gives a little taste of N4

    http://www.tridium.com/tridium-talk
  36. Thread: tabbed pane

    by klrogers
    Replies
    7
    Views
    313

    It should have labelpanes under the tabbed pane...

    It should have labelpanes under the tabbed pane not canvas panes.

    module://docUser/doc/bajaui-TabbedPane.html

    Kevin
  37. Replies
    7
    Views
    428

    This might help explain the relationships ...

    This might help explain the relationships

    574071
  38. Replies
    17
    Views
    1,048

    While I am certainly interested in this...

    While I am certainly interested in this discussion, I don't think we should be talking numbers here in the open section of the forum. Everyone involved so far is a professional member so maybe a move...
  39. Good work, can we look forward to a Tridium...

    Good work, can we look forward to a Tridium driver for M-Net :)
  40. You have mail

    You have mail
  41. Replies
    1
    Views
    296

    Check out the "Report Service" Kevin

    Check out the "Report Service"

    Kevin
  42. I am not sure that this will work with all...

    I am not sure that this will work with all versions and manufacturers, but you can try this:

    Copy the config.bog file
    Create a dummy station on your laptop
    Copy the copied config.bog into the...
  43. Replies
    51
    Views
    3,031

    The full website address is :...

    The full website address is : "http://www.pecomanufacturing.com/assets/docs/datasheets/t180-t170-peco-data-sheet.pdf" hopefully it will not get shortened when I post this.

    I am not a "Trane" guy,...
  44. Replies
    51
    Views
    3,031

    A lot depends on your type of tenants, High end...

    A lot depends on your type of tenants, High end condo's you need to keep them happy at all times, doing the best you can with what you got. Section 8 buildings or similar, Heat Nov 15th until Mar...
  45. Replies
    51
    Views
    3,031

    Ideally the thermostats in the resident spaces...

    Ideally the thermostats in the resident spaces should know which mode the system is in, this can be done either of two ways, a communicating thermostat connected back to the control system (probably...
  46. Replies
    2
    Views
    501

    Good material for controls techs.

    Contemporary Controls has put together a book that contains various previously published articles and some updated stuff, it is titled Network Communications for Buildings, and covers in fairly fine...
  47. Replies
    2
    Views
    322

    I suggest that you ask your question in this...

    I suggest that you ask your question in this section: http://hvac-talk.com/vbb/forumdisplay.php?1-AOP-Residential-HVAC
  48. Replies
    14
    Views
    874

    Are you sure you are talking about the same...

    Are you sure you are talking about the same thing, the niagaraDriver device limit is for stations pulled in to the niagara network not Jaces on the navigation tree.
  49. Thread: EC BOS ?

    by klrogers
    Replies
    4
    Views
    330

    Or Platform Service container view

    Or Platform Service container view
  50. Replies
    8
    Views
    687

    Thanks for the links. I'm happy to help you or...

    Thanks for the links.

    I'm happy to help you or anyone out when I can, I have received help from many other members over the years and like to return the favor. Despite its occasional rants and...