Search:

Type: Posts; User: grgjohno

Page 1 of 3 1 2 3

Search: Search took 0.01 seconds.

  1. Replies
    4
    Views
    188

    Thanks for the info guys, The existing version...

    Thanks for the info guys,

    The existing version we have does have the option, however Honeywell have admitted that it doesn't work, and the only solution is to upgrade the software to a later...
  2. Replies
    4
    Views
    188

    HW EBI Dial-out to cell phone

    I have a Honeywell LON site where the customer wants to receive alarms on there cell phone.

    The EBI version does not support dial out capability (I think its 410).

    Does anybody know of an...
  3. Replies
    5
    Views
    324

    I got the HVACRcontrol CCN gateways for about...

    I got the HVACRcontrol CCN gateways for about $750.

    It turned out cheaper than I could get the 33CNTRAN for multiple chillers (1x device can do up to 6 chillers I think).
    But AHI put big markups...
  4. Replies
    5
    Views
    324

    Prodialog machines were made in France. They do...

    Prodialog machines were made in France.
    They do use the standard CCN proprietary protocol, and the translator does work on it.
    However you do need Network Service tool or Comfortview to configure...
  5. Replies
    7
    Views
    528

    There was a free bacnet/IP discovery tool someone...

    There was a free bacnet/IP discovery tool someone developed and posted on here.........I cant remember the name of it, but if you do a search you should be able to find it.
    Do you have the Daikin...
  6. You could try something from Loytec, they have...

    You could try something from Loytec, they have some good Lon/Bacnet interfacing devices.
    I've used them before and been satisfied with them.
  7. Replies
    2
    Views
    478

    Always good to have some newer reference...

    Always good to have some newer reference material!

    Thanks!!
  8. Thread: StruxureWare

    by grgjohno
    Replies
    12
    Views
    1,239

    Actually, Schneider employed Loytec to assist...

    Actually, Schneider employed Loytec to assist them with the development of Struxureware.
    So its no surprise that it appears very similar.
  9. Replies
    5
    Views
    712

    The loytec touchscreens are good to use, I like...

    The loytec touchscreens are good to use, I like them.

    The configuration can be a bit quirky at times, but they are very flexible.
    I have never had any problems with integration into LON or Bacnet...
  10. Replies
    13
    Views
    1,623

    I wish we new this issue before we installed one...

    I wish we new this issue before we installed one on our job!!

    We got a Mitsubishi and a LG side by side, communicating to a Loytec device over Bacnet/IP.
    The Mitsubishi Gateway is fine never...
  11. Replies
    6
    Views
    687

    Yeah thats true, however we have programmed...

    Yeah thats true, however we have programmed systems where we needed to modify the programming in some VAV's, so we used the CC6400 to hold the B++ programs which then did Read/Writes to the VAV...
  12. Replies
    4
    Views
    718

    Deos have a pretty wide range of control products...

    Deos have a pretty wide range of control products and their method of programming is pretty cool.
    Basically as you configure and program the graphics and are being made in the background. Obviously...
  13. Replies
    40
    Views
    13,885

    This type of problem with uploading, is usually...

    This type of problem with uploading, is usually caused by poorly written programs which are using excessive resources from the CPU.
    If you do a diagnostic check on the controller you will probably...
  14. Replies
    6
    Views
    1,270

    I had to run Win 7 in XP mode to make the com...

    I had to run Win 7 in XP mode to make the com port drivers work.
  15. Thread: Carrier 6400

    by grgjohno
    Replies
    3
    Views
    701

    This is the config manual. Should still be...

    This is the config manual.
    Should still be current.
  16. Replies
    5
    Views
    920

    In this pic below, I have pulled in a Modbus...

    In this pic below, I have pulled in a Modbus datapoint from a Chiller, so that it can be displayed.
    382451

    So set your Johnson datapoint properties that you want to display on the L-Vis to write....
  17. Replies
    5
    Views
    920

    Another thing to consider is the data point flow....

    Another thing to consider is the data point flow.
    The Cooling Valve output needs to be a write from the JCI PPG controller, because it is writing the value to the network.
    However the Loytec needs...
  18. Thread: Touch panels

    by grgjohno
    Replies
    20
    Views
    1,900

    I know the Loytec touch screens have dual nics on...

    I know the Loytec touch screens have dual nics on their 12" and 15" screens.
    I am sure you can get them for less than $4k?!
    They are Bacnet and OPC compliant, not sure if it's what you are looking...
  19. Replies
    14
    Views
    2,863

    That Floorplanner looks pretty good, I played...

    That Floorplanner looks pretty good, I played around with it for about 5 mins and thought that it is a nice and easy interface to use.
    A lot simpler than 3DSMax or even Sketchup IMHO, and the...
  20. Replies
    6
    Views
    1,012

    Chadtech, bear in mind that there are two CView...

    Chadtech, bear in mind that there are two CView versions.

    CView Single User
    CView Multi User


    Typically, a device called a Carrier TELink is needed on the owners site.
    This has a PCMCIA...
  21. Replies
    5
    Views
    1,472

    The few brain cells I've got left, can't seem to...

    The few brain cells I've got left, can't seem to stretch far enough to get a good grip with VBA and all its capabilites......I've been a bit daunted by it and haven't had the time to sit down long...
  22. Replies
    5
    Views
    1,472

    Seen it and used it....... It is pretty good...

    Seen it and used it.......

    It is pretty good for quoting projects, if you take the time to set it up properly.
    You also need to have Visio installed to make maximum use of the software.
    (it is...
  23. Replies
    57
    Views
    5,061

    Strange how some guys are finding it hard to get...

    Strange how some guys are finding it hard to get hold of the Loytec stuff here in the land of Oz.
    I've had no problems so far with them, and they have been extremely helpful with great Tech support....
  24. Replies
    33
    Views
    6,644

    Mind if I jump on the bandwagon here?

    Mind if I jump on the bandwagon here?
  25. Replies
    4
    Views
    873

    Eureka!!! Hey Incontrol, you got me revisiting...

    Eureka!!!

    Hey Incontrol, you got me revisiting this issue (it's hard to think straight after a late night and a sore head).

    If you Google gif2mng there is a free converter which will convert...
  26. Replies
    4
    Views
    873

    I had this issue as well.....and the reply I got...

    I had this issue as well.....and the reply I got back from tech support is that .gif animations can only use 256 colours therefore transparency is not used.
    If you need the transparency then L-Vis...
  27. Replies
    10
    Views
    1,819

    Hi Hungry, I've got a Richards Zeta Training...

    Hi Hungry,
    I've got a Richards Zeta Training package that includes PerfectHost 6.16.04
    Of course you will need the dongles to get it to work properly.

    Not sure if it helps????

    Drop me an...
  28. Replies
    8
    Views
    1,428

    Hey Kontrol, Thanks for the link to the Eikon...

    Hey Kontrol,
    Thanks for the link to the Eikon tool,
    I've been looking for that for ages, and had given up on it.

    :cheers:
  29. Hey Davo!! Business is doing pretty good over...

    Hey Davo!!

    Business is doing pretty good over here now........best move I ever made was taking the leap to "go it alone".

    drop me an email and let me know how things are with you these days....
  30. Does this help

    I have a site, which I am ripping the Johnson N2 system out, and replacing it with a Loytec network.
    The Carrier chillers are 30HXC French machines (still CCN protocol)
    The high level interface...
  31. Great job Frank! haven't tried it yet, but I am...

    Great job Frank!
    haven't tried it yet, but I am sure I'll have to at some stage.

    Cheers
  32. Replies
    5
    Views
    1,344

    If your looking for the "Carrier 6400 Overview &...

    If your looking for the "Carrier 6400 Overview & Config Guide P/N 808-891"
    drop me your email and I'll flick it over to you, yes it is 642 pages.

    Cheers
  33. Replies
    1
    Views
    517

    Softeware points can be used to: Display...

    Softeware points can be used to:

    Display values that are calculated in a B++ program, or these values as an input to a standard algorithm.
    Make the output of a standard algorithm, the input to...
  34. Replies
    3
    Views
    621

    It can actually be configured in CView by...

    It can actually be configured in CView by displaying the Occupancy Table then changing the view from "Graphical" to "Table".
    The after hours point can then be configured as a Temperature Sensor...
  35. Hi Blockey, Any chance of getting you to drop...

    Hi Blockey,

    Any chance of getting you to drop a copy in my mailbox?

    Email addy is in my profile.

    Thanks in advance
  36. Replies
    262
    Views
    17,853

    I would like to think that I understand where...

    I would like to think that I understand where ControlBIZ is coming from as I am a new business owner in this field.
    My current business policy is to remain as independant as possible, with as...
  37. Replies
    36
    Views
    7,012

    Hey jogas, Any chance of grabbing a copy as...

    Hey jogas,
    Any chance of grabbing a copy as well???

    If so your help would be most appreciated.
  38. Replies
    38
    Views
    4,133

    JRINJAX, Sounds like we have a bit in common,...

    JRINJAX,

    Sounds like we have a bit in common, as I am in the same boat as you. Lot of experience on the CCN stuff, but am also finding a lack of support, now that I am out on my own, and now they...
  39. Replies
    16
    Views
    6,283

    Whec, I actually use the same method ausccn...

    Whec,
    I actually use the same method ausccn recommended, but it is a bit cumbersome cause you need to plug the Ethernet converter into a 24V supply (which is not always readily available).
    But it...
  40. Replies
    16
    Views
    6,283

    Short answer: No! CView was designed only...

    Short answer:

    No!

    CView was designed only for a serial port, and doesn't take into account the config of USB connections. Carrier won't spend any resources to do this as it will be phased out...
  41. Replies
    4
    Views
    2,530

    Mikey check your email, I sent you some basic...

    Mikey check your email, I sent you some basic info on it.

    No! the 19XR chillers are a Centrifugal machine and the 30GX is screw machine so the profiles are totally different.

    Also I bet the...
  42. Replies
    3
    Views
    1,188

    Crab, check your email I sent you some info on...

    Crab, check your email I sent you some info on CCN Bus issues.
  43. Replies
    2
    Views
    856

    Staefa Smart II DDC Info

    Does anyone have any tech info on the the Staefa Smart II DDC Controllers?

    I need to do some I/O additions but I'm not sure if there is sufficient capacity on the controllers.

    Any help is...
  44. Thread: CARRIER DDC

    by grgjohno
    Replies
    5
    Views
    1,082

    I found the Carrier stuff easy to learn on, as it...

    I found the Carrier stuff easy to learn on, as it was primarily orientated towards control of HVAC equipment, without getting too involved in all the added capabilities that a TRUE control system is...
  45. Thread: Rolo......

    by grgjohno
    Replies
    9
    Views
    977

    Struth Dave! You know how to drag up old...

    Struth Dave!
    You know how to drag up old memories!!!

    but they were funny.......lol

    R obertshaw
    O ver
    L ots of
    O thers
  46. Replies
    13
    Views
    1,877

    First thing is that the Chillervisor which uses...

    First thing is that the Chillervisor which uses the ACR Algorithm in determining Chiller/s Start is probably not your best option.
    I think there may have been some miscommunication in the discussion...
  47. Replies
    7
    Views
    1,043

    Is this similar to what you have on site? If not...

    Is this similar to what you have on site?
    If not then what connections are there on the module you have?

    Do you have any bridge modules on the network?

    How many devices are on the CCN?

    It...
  48. Replies
    13
    Views
    1,375

    My question is, if you can't find the Chillers...

    My question is, if you can't find the Chillers Translator, then how are you going to import the .cwx file????

    Like you I've only ever commissioned field fitted LEI's, not the factory fitted ones....
  49. Thread: Carrier NST V

    by grgjohno
    Replies
    5
    Views
    849

    Thats what I thought, but I'm down in OZ, and...

    Thats what I thought, but I'm down in OZ, and Carrier over here see the product as only available to their branches.

    They have the mentality, that Controls Contractors are the "enemy" as they...
  50. Thread: Carrier NST V

    by grgjohno
    Replies
    5
    Views
    849

    Carrier NST V

    Can anyone tell me if Carriers Config tool 'Network Service Tool V' is available to contractors?

    Carrier have asked me to do some work for them, so I said I needed to purchase the software to...
Results 1 to 50 of 118
Page 1 of 3 1 2 3

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Quality Home Comfort Awards