Search:

Type: Posts; User: ask_eddie

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    18
    Views
    2,134

    5 tons often exceed 10 lbs, Rheem 5 ton heat...

    5 tons often exceed 10 lbs, Rheem 5 ton heat pump 17lbs

    4 ton rheem tax credit 16 seer / 18 seer coil was 14 lbs
  2. Thread: lennox

    by ask_eddie
    Replies
    1
    Views
    1,247

    lennox

    i needed some information if someone could please help , the compressor is out and im not sure of the warranties on the unit . I can see it is a 3.5 ton 13 seer heatpump and it is an 2005 model.
    ...
  3. Replies
    1
    Views
    463

    combustion air

    I need some help with a boiler room. The spec's for the room require a

    8' x 10 ' louvered vent with it screened on the back side. Ive seen them before on buildings. my local supply house can...
  4. Replies
    22
    Views
    1,502

    york ?

    York is only high end if you go York/Coleman/Luxaire or York / goodman / nordyne
  5. Replies
    11
    Views
    1,108

    The RPRL is a very good 2 stage heat pump...

    The RPRL is a very good 2 stage heat pump communcating unit i have installed them with good results , I have a heat pump system in my house and the is the unit I would replace it with if mine were to...
  6. Replies
    26
    Views
    2,802

    the 2.5 ton is 4 inchs shorter, it will produce...

    the 2.5 ton is 4 inchs shorter, it will produce 1033 cfm at .05 static
    the 3 ton model will produce 1205 cfm at .05 static.
    the 2.5 ton will still have a txv for 2.5 tons.
    on a heat pump...
  7. Thread: nextel!!

    by ask_eddie
    Replies
    15
    Views
    1,143

    we quit using nextel years ago, bad signals plus...

    we quit using nextel years ago, bad signals plus nothing like someone yelling on the radiio while your with the customer. they are so annoying to listen to people on while in public.
  8. Replies
    10
    Views
    1,423

    i wouldnt accept an all-style

    i wouldnt accept an all-style
  9. Replies
    16
    Views
    2,138

    Rheem only has an idiot chart of where the...

    Rheem only has an idiot chart of where the pressure should be with outside temp. I asked their tech rep why they wont give the sub-cool. I got the run around, I knew the basic answer as there is a...
  10. Replies
    8
    Views
    861

    I would almost bet that the return air is short,...

    I would almost bet that the return air is short, maybe even causing whistling,or whining at the grill with the 4" filter.
  11. Thread: A/C problems

    by ask_eddie
    Replies
    36
    Views
    1,609

    I wouldnt hook up a 5 ton on a 3 ton drive for...

    I wouldnt hook up a 5 ton on a 3 ton drive for any some of money, and any company that would are not professionals.
  12. Replies
    9
    Views
    751

    In north texas I prefer 2 stage heating.

    In north texas I prefer 2 stage heating.
  13. Replies
    69
    Views
    6,957

    not all compressors are created equal, not all...

    not all compressors are created equal, not all copeland scolls are the same, i would bet money the exact same compressor is not in the rheem as the goodman. IN fact there is the Alliance plant in...
  14. I have been through this before, any of the ...

    I have been through this before, any of the "TWE" coils are almost as much as a new air handler, while the installation cost is more for the new air handler you would be getting a better warranty. i...
  15. I have been through this before, any of the ...

    I have been through this before, any of the "TWE" coils are almost as much as a new air handler, while the installation cost is more for the new air handler you would be getting a better warranty. i...
  16. Replies
    21
    Views
    1,225

    If a Kia is the same Lexus , only the brand name...

    If a Kia is the same Lexus , only the brand name is the difference, then yes a Goodman and a Carrier are Exactly the same. Take bids and consider the installing company.
  17. Replies
    22
    Views
    2,394

    Normally you would think a local electrician...

    Normally you would think a local electrician would know about a cities' local code. There is no NEC code that says a meter has to be on the front of the house, and as we all know that wouldnt fly in...
  18. Replies
    17
    Views
    3,123

    As already said, the jez unit will be replaced ...

    As already said, the jez unit will be replaced if the compressor were to fail in the first 5 years, and after that another compressor only exchange for the other 5 years.
  19. Replies
    23
    Views
    2,495

    I have no units without expansion valves, while i...

    I have no units without expansion valves, while i have had expansion valves
    fail, I've had to clean way more orffices.
  20. Replies
    20
    Views
    1,665

    Let's hope he doesn't have to fill out the...

    Let's hope he doesn't have to fill out the warranty card information.
  21. Replies
    23
    Views
    19,799

    You could also run into what I have as mentioned...

    You could also run into what I have as mentioned in a previous thread. It is an Ameristar system, an american standard builders model with an aspen coil.. the coil is now leaking and no one wants...
  22. Replies
    18
    Views
    2,694

    Any 12 seer rheem 8 years old would still have...

    Any 12 seer rheem 8 years old would still have 2 years left on the compressor warranty
  23. Lets not forget it would have to be connected to...

    Lets not forget it would have to be connected to the exact same duct work
    to check the air flow before begining any test.
  24. Replies
    20
    Views
    1,665

    If the house was built in 2008 there was probably...

    If the house was built in 2008 there was probably on the standard 1 year labor warranty, and possible 5 or 10 warranty on parts. Any company can get the parts warrantied if it is the say the coil. So...
  25. Replies
    12
    Views
    956

    If it has a pilot light, its "probably" too old....

    If it has a pilot light, its "probably" too old. Most manufactures discontinued pilot lights 20 years ago.

    one brand did have the one that lit a pilot on every demand, but come on if has a pilot...
  26. Replies
    10
    Views
    2,144

    when you figure out the basics of the system you...

    when you figure out the basics of the system you have and what you need with ductwork and insulation issues and or windows, You should consider a better brand than Frigidaire, rheem is a good brand...
  27. Our local supply house offers ducane, i consider...

    Our local supply house offers ducane, i consider it buliders grade/ rent house equipment. its like most equipment of this type, its fine for someone else property.... but i wouldnt want it on on mine.
  28. Oh i understand, I actually use amsco supply out...

    Oh i understand, I actually use amsco supply out of sherman for rheem... i was trying out american standard when i came across a deal where i have to offer trane.... Trane made me quit offering...
  29. second Line

    while offering a second line in theory seems line such a great idea, but it is such a pain when offer serveral seers and in 2 brands its quite the pain in the
    rear .. when trying to offer 2 brands...
  30. Replies
    16
    Views
    3,461

    Its easy for people to tell you that you need the...

    Its easy for people to tell you that you need the top of the line 95% furnace and them a 20 seer a/c . What you need to consider is how long are you going to live in your present house , how much is...
  31. If I'm not mistaken, that unit should have a 20...

    If I'm not mistaken, that unit should have a 20 heat exchanger warranty and its only 15 years old. Can you get the model and serial number from the unit? And perhaps one thr carrier/payne dealers...
  32. You have a couple choices Follow the advice of...

    You have a couple choices Follow the advice of the 5 contractors that have seen the job or add supplemental air , as suggested a mini split or since it has so many windows add a window unit or a PTAC...
  33. Replies
    14
    Views
    5,832

    Matching Trane coil.

    Matching Trane coil.
  34. Really? I live { unfortunely} in mobile home ...

    Really? I live { unfortunely} in mobile home HELL in North Texas While you are correct in most cases about the Rpm's ect.... Here is the real problem with mobile home equipment there is no...
  35. Just look at any equipment manufacture,...

    Just look at any equipment manufacture, goodman..rheem...ect. the equipment is not approved or recommended for mobile homes. I did make a mistake as to the up flow and the down flow systems. It...
  36. there are 2 types of moblie/manufactured homes......

    there are 2 types of moblie/manufactured homes... first is the true class of manufactured home, it is an upflow normally with an 18" duct directly off the top of the electric air handler, you can...
  37. Replies
    11
    Views
    2,308

    From the rheem web site on the rgrl furnace. ...

    From the rheem web site on the rgrl furnace.



    GAS VALVE
    With the call for ignition, the integrated furnace control then opens the gas valve. The redundant gas valve is a 24 volt...
  38. Replies
    46
    Views
    13,938

    I took the Tyler Texas Trane plant tour in...

    I took the Tyler Texas Trane plant tour in November and they went over this new unit included the quick disassembly feature. It is a game changer.
  39. Replies
    67
    Views
    25,260

    Ethics

    I have worked within one of these types of programs but not Costco, And to install Equipment on a project like this would be in beach of contract. You can not install equipment after you've bid the...
  40. Replies
    49
    Views
    4,562

    I'm sure its always been good practice everytime...

    I'm sure its always been good practice everytime a system is opened, however i tend to doubt a some people did it with 22. But with 410a, the biggest enemy is moisture I would recommend it everytime...
  41. Thread: dry units.

    by ask_eddie
    Replies
    32
    Views
    3,931

    Trane

    Yesterday my Trane rep. said they'd have heatpump models.
  42. Replies
    18
    Views
    1,731

    I went yesterday and inspected the job. The owner...

    I went yesterday and inspected the job. The owner is of course looking for the bottom dollar. he handed me the other guys bid and said beat it, of course there is no way. The other contractor knows...
  43. Thread: payne

    by ask_eddie
    Replies
    3
    Views
    524

    Sorry for the sideways pic's Im not sure how to...

    Sorry for the sideways pic's Im not sure how to straigten them out, of course i can rotate them on my computer but im not sure how to save them that way
  44. Thread: payne

    by ask_eddie
    Replies
    3
    Views
    524

    payne

    I'm not a payne/ carrier dealer , but i dont think this is a downflow model.
    hall of shame ?
  45. Replies
    11
    Views
    2,308

    Rheem

    I am a Rheem dealer and if i want an LP furnace it has to be converted. I personally can't order a propane. The oriffices are all brass, It's been awhile since I've done one, but i believe the spring...
  46. Replies
    18
    Views
    1,731

    open cell foam

    I'm going to bid a new house tomorrow, the owner tells me he's going to use open cell foam on the outside walls. and on the underside of the roof decking.
    From what I've read open cell foam is...
  47. Replies
    13
    Views
    1,084

    I would not consider "upgrading to spark...

    I would not consider "upgrading to spark ignition" . I havent ever seen a kit and I wouldnt install one on 35 year old furnace. As they tell me everything UL listed when it was produced, I wouldnt...
  48. That is the t-stat we sell unfortunatly, while we...

    That is the t-stat we sell unfortunatly, while we dont have a lot of problems with them, I've seen them doing some crazy things and have to be reset.
    This all our local supply house offers since...
  49. Replies
    2
    Views
    488

    Those year models of weatherking had a five...

    Those year models of weatherking had a five compressor and five on parts , If the inside was freezing up it sounds like the condensing unit was still working to me. If it was pumping enough to...
  50. Thread: dry units.

    by ask_eddie
    Replies
    32
    Views
    3,931

    Also I'm not sure about all the manufactures, but...

    Also I'm not sure about all the manufactures, but Rheem will only have straight cool no heat pumps
Results 1 to 50 of 158
Page 1 of 4 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event