  1. Replies
    13
    Views
    562

    I found a few videos on the YouTube about system...

    I found a few videos on the YouTube about system clean up after burnout. What I got out of it, is that: flushing the evaporator coil with the expansion device left in, is pretty much pointless....
  2. Replies
    13
    Views
    562

    I'm sorry Techman, what is SGMI? ( I only had one...

    I'm sorry Techman, what is SGMI? ( I only had one coffee this morning, so bare with me please.)
    The line set is about 50 Ft, not underground, but I'm planing on putting an inverted P trap on the SL,...
  3. Replies
    13
    Views
    562

    This is a 5 Ton, big condenser, so I would like...

    This is a 5 Ton, big condenser, so I would like to save it if at all possible. Plus, the supply house already agreed to replace the compressor under warranty. Thank you guys for your help! I have...
  4. Replies
    13
    Views
    562

    System Flush question

    Hi guys! I'm looking at 5 Ton R22 Goodman split. It had a compressor burnout at 4 years of age. After the burnout, no system cleaning has been done. New compressor has been installed with new large...
  5. Replies
    14
    Views
    1,215

    If I end up building the AH, it will have no heat...

    If I end up building the AH, it will have no heat strips. Here in LA, heat pumps don't go in to defrost. It just does no get that cold here.
  6. Replies
    14
    Views
    1,215

    The closet has a raised floor, and the return is...

    The closet has a raised floor, and the return is under the floor. Combustion air comes in through the wall vents.
    I did talked to the home owner about possibly dropping the floor of the closet. But...
  7. Replies
    14
    Views
    1,215

    Thanks Bill, that's not a bad idea. Slab coil may...

    Thanks Bill, that's not a bad idea. Slab coil may actually fit inside the plenum. If I can find one the right size.
    I sense you and the other guys are not fond of the idea of using the furnace to...
  8. Replies
    14
    Views
    1,215

    There is the supply plenum, but most of it is...

    There is the supply plenum, but most of it is bearied inside the ceiling, only about 4" is sticking out. I would have to do some exploratory surgery, just to find out how big the plenum really is....
  9. You have a Silicone Nitrite Ignitor, controlled...

    You have a Silicone Nitrite Ignitor, controlled by a adaptive learning routine. You can ohm out the igniter, 10.9-19.7 Ohm would be a heathy reading for a cold Ignitor. Do make sure the voltage is...
  10. Replies
    24
    Views
    1,795

    I have to retract on that, if the ICC detects LPC...

    I have to retract on that, if the ICC detects LPC fault when it gets the Y signal, it will not start the compressor. I think you already figured it out, it got to be the board. Let us know when you...
  11. Replies
    14
    Views
    1,215

    It will be a heat pump. I would use a "A" coil...

    It will be a heat pump. I would use a "A" coil with heat pump TXV and match it with a heat pump condensing unit. Should work right?
  12. Replies
    24
    Views
    1,795

    The ICC ignors the LPC for 90 sec. at start up,...

    The ICC ignors the LPC for 90 sec. at start up, so that's probably one thing you don't need to worry about.
  13. Replies
    14
    Views
    1,215

    Custom Air Handler

    I have a project, to add a cooling to an existing gas furnace heating sys. The furnace is located in a closet, with floor to ceiling clearance of 48". My original plan was, to get rid of the furnace...
  14. Replies
    44
    Views
    3,451

    Of all the noises the furnace makes, the spark is...

    Of all the noises the furnace makes, the spark is the least audible. I thing the governing issue here is the production cost. If they can gat a good deal on a train load of spark modules, they will...
  15. Replies
    2
    Views
    979

    Very old Wall Furnace

    This is 40 year old wall furnace that has been condemned. My question is, if you guys look to the left of the gas valve, you can see a copper coil. Anybody have any idea what this may have been for?...
  16. Thread: Furnace Vent

    by Airczech
    Replies
    4
    Views
    1,036

    These are the "B" type double wall vents for wall...

    These are the "B" type double wall vents for wall furnaces. Some are clean, and others have a lot of soot on them. Most likely a combustion problem, but I sure would like to hear your opinion on it.
  17. Thread: Furnace Vent

    by Airczech
    Replies
    4
    Views
    1,036

    Furnace Vent

    I have been doing some basic maintenance work for property management companies. Went up on the roof to check the furnace vents. When you guys see a vent pipe that is all black of soot deposits, what...
  18. Well, what would be the worst case scenario? The...

    Well, what would be the worst case scenario? The controll board detects pressure switch problem and locks out the unit? Or the switch holding closed while the inducer isn' pulling sufficient draft?...
  19. Replies
    6
    Views
    1,341

    Yes, old furnace, no control board. And yes this...

    Yes, old furnace, no control board. And yes this is the diagram I'm looking at. The untimed load would be the gas valve and ignition? And continues and cooling fan would still be routed through the...
  20. Replies
    6
    Views
    1,341

    Wiring question

    I have a ICM 251 fan control. Delay on brake, delay on make. While controlling the fan in heating mode is fairly simple, my question is how to wire this to maintain continues fan and cooling mode fan...
  21. Pressure switch

    Just picked up few pressure switches at Johnstone yesterday. Cheep black plastic, made in Costa Rica.
    Fixing a York, 80% single stage furnace. The old pressure switch would close initially, but...
  22. Replies
    31
    Views
    3,121

    Truck lettering

    Back in 2005 I rear ended a car on the freeway while driving my beautifully lettered work truck. It was a set up. The car in front of me had the brake lights disabled. Another two cars driving on...
  23. Replies
    3
    Views
    741

    Furnace control board

    Do you guys have a good universal control board that you carry in a van, that works for some or most of the early models 80% furnaces?
  24. Replies
    51
    Views
    7,722

    rx11 Flush

    Have been using rx11 to flush my line sets. A lots of it, until it comes out clear and than some more. Insane amount of nitrogen to get it all out. Than puling deep vacuum, brake with N and puling...
  25. Thread: Qwick Books

    by Airczech
    Replies
    5
    Views
    823

    Qbooks

    I have been using 2006 version Quickbooks Pro on my MacBook. Works fine for organizing your finances and keeping clean books. Stable, no major issues. Will upgrade soon to the newest version.
  26. Replies
    19
    Views
    6,405

    Flue damper

    Flue Damper shown in relation to the inducer. Makes a little sense. The importance of having a clean and non-obstructed HX being stressed at every level, this damper effectively reduces the flue gas...
  27. Replies
    19
    Views
    6,405

    Flue damper

    I have had the same problem on a Bryant 2 Ton Gas Pack, roof top unit. With new inducer, new rollout switch, gas pressure adjusted, the unit continued to cycle off on the rollout switch. The flame...
  28. Replies
    21
    Views
    3,728

    Has anyone actually know of someone who got...

    Has anyone actually know of someone who got caught venting and had to pay the fine?
  29. Thread: Flue Gas Vent

    by Airczech
    Replies
    4
    Views
    533

    Still learning....

    Thanks Flange, this is a good info! Heaterman, it's the
    Bryant 582ANW024040NAAD - fairly new unit, installed couple years ago by someone else. I went ahead and inspected the other units on the...
  30. Thread: Flue Gas Vent

    by Airczech
    Replies
    4
    Views
    533

    I should add, this is Bryant, 2 Ton cooling,...

    I should add, this is Bryant, 2 Ton cooling, 40000 BTU gas heating unit. I have seen the same restrictions on Carriers also.
  31. Thread: Flue Gas Vent

    by Airczech
    Replies
    4
    Views
    533

    Flue Gas Vent

    I work on RTU gas-electric packages. One kept going off on the FRS. The flame did not look right. New inducer, manifold pressure adjusted, still the same problem. I noticed a plate in the flue gas...
  32. Replies
    156
    Views
    57,703

    Sticky: So far I'm the only one in the Los Angeles area.

    So far I'm the only one in the Los Angeles area.
  33. Replies
    1
    Views
    643

    Home beer brewing - cooling project

    I would like to set up a cooling unit to draw the brew temp from 200+ deg. down to about 60 deg. I have a few water fountain units that I was going to use for parts. The heat exchange copper coils...
  34. Replies
    2
    Views
    563

    Another school project

    Hi guys! A question came up today in the class about a system pump down. Closing the high side service valve while running the system and trapping the ref in the condenser, before opening the system....
  35. Replies
    1
    Views
    462

    I'm a student my self, taking HVAC classes at...

    I'm a student my self, taking HVAC classes at community collage. The book we are using right now is Fundamentals of HVAC/R by Carter Stanfield and David Skaves. Very good book, over fifteen hundred...
  36. Replies
    26
    Views
    2,806

    I would like to get one of those heavy duty steel...

    I would like to get one of those heavy duty steel boxes and bolt it to the floor and keep all my tools in it. Than, they will probably steel the whole van!
  37. Thread: Strait A!

    by Airczech
    Replies
    3
    Views
    479

    Strait A!

    Hey guys,
    I just thought I would stop by and let you know I just finished the summer semester over at the El Camino Collage! This was my very first HVACR class on my way to become a Tech, and I...
  38. Replies
    13
    Views
    2,906

    Hi Guys, I have been considering Penn Foster for...

    Hi Guys,
    I have been considering Penn Foster for a while, but I have already read a lot of books and manuals on my own, so I went to our local community collage for some hands-on. The class is...
  39. Replies
    0
    Views
    282

    Has anyone been to El Camino collage?

    Hi guys, hope everybody is well.
    Question for all the guys here in California, Los Angeles.
    Has anybody been to either El Camino Collage or Harbor Occupational Center in San Pedro for your HVAC...
  40. Replies
    30
    Views
    1,401

    Well, you certainly came to the right place. I'm...

    Well, you certainly came to the right place. I'm an A/C student my self, and this forum is absolutely amazing! The amount of information that's hiding under each and every folder is insane! I always...
  41. Replies
    29
    Views
    2,271

    Hey guys, maybe now is the time to go out and...

    Hey guys, maybe now is the time to go out and sell some EAC systems! Guaranteed to kill every virus and bacteria in the house. And since the flue is a Mexican bug, I prescribe a shot of Tequila!
  42. Thread: Turn signals

    by Airczech
    Replies
    31
    Views
    1,695

    Back in the good old days, we used to go camping...

    Back in the good old days, we used to go camping a lot and I decided to install a CB radio in my truck. Thinking how great it will be to talk to all the nice folks on the road while driving. Little...
  43. Replies
    27
    Views
    1,549

    Give the guy some credit. He spends money on...

    Give the guy some credit. He spends money on tools, not toys.
  44. Replies
    45
    Views
    2,049

    I have never killed a charger with an inverter,...

    I have never killed a charger with an inverter, but I did killed an inverter with a charger. It was my 2500 W unit. The charger that killed it was a kid's toy charger. I have overloaded the inverter...
  45. Replies
    64
    Views
    6,590

    Buy a Mac. I have never owned a one single piece...

    Buy a Mac. I have never owned a one single piece of anti virus software. And I have been on the internet for longer than I care to admit. On the other hand, Mongolia depends on PC owners for steady...
  46. Replies
    20
    Views
    1,440

    There are people here in LA, who demolish old...

    There are people here in LA, who demolish old houses, load everything up on a truck and haul it down to Mexico. Over there, they sell it as a construction material, even an old garage door! Who...
  47. Replies
    28
    Views
    2,202

    A smart man can learn something even from a fool....

    A smart man can learn something even from a fool. A fool never learns.
  48. Replies
    11
    Views
    541

    I'm also new to this site. Don't have my pro...

    I'm also new to this site. Don't have my pro membership yet, but I'm already learning a great deal! Forums are by by far the best source of information.
  49. Company vehicles

    No changes, no alterations. Not even a bumper sticker. Standard protocol.
  50. Thread: Mushrooms???

    by Airczech
    Replies
    29
    Views
    3,164

    I was born and raised in the Check Republik -...

    I was born and raised in the Check Republik - central Europe. Picking wild rooms was the thing to do, every year during the summer and the fall. I remember getting up at five in the morning and...
Results 1 to 50 of 111
Page 1 of 3 1 2 3

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Quality Home Comfort Awards