  1. Replies
    23
    Views
    732

    did it solve your problem with new TXV? i would...

    did it solve your problem with new TXV? i would go with adjustable one.
    I've had new Oem txv that having the same symptom.
  2. now tech support said the board is obsolete, can...

    now tech support said the board is obsolete, can be repaired for $10K. wow.
  3. YORK YPAL050 Optilogic stuck in self checking mode.

    could not recall full model#. waiting to hear back from tech support.

    Optilogic Control Center stuck in self checking mode .
    display shown

    Version A09
    Address 32
    Status No comm
    Startup OK...
  4. Thread: Reliatel Bible

    by cfe
    Replies
    49
    Views
    2,774

    Hi Rundawg, could you send me one please? much...

    Hi Rundawg, could you send me one please?
    much appreciated.
    need to sharpen my knowledge and future reference. we service and maintaining 5 trane unit @ 50 ton.

    thanks.
  5. Replies
    19
    Views
    3,371

    how do you test the IGV operation? is it thru the...

    how do you test the IGV operation? is it thru the I/0 connector and danfoss sofware on your computer ?
    i have a turbocor compressor # 2 that IGV only go up to 12 % . the ball bearing not even move...
  6. thank you . much appreciated.

    thank you . much appreciated.
  7. what is the tonnage of this copeland 6RK2-3500-TSE.

    need to change out the leaky TXV but could not tell what is the capacity.

    this green unit has no make and model. seems like its a custom made cooling unit with dual 6RK2-3500 Compressor.
    nothing...
  8. Replies
    19
    Views
    3,371

    what happen to the operation before repaired? did...

    what happen to the operation before repaired? did it not maintaining set point or else?
    we have thermal care chiller that using 2 turbocore compressor. so far is operate smoothly.
  9. Replies
    37
    Views
    1,274

    if the compressor capacity is almost the same, i...

    if the compressor capacity is almost the same, i think it should work good, not as new spec condition.
    this unit feel like walk in cooler temp .
  10. Replies
    37
    Views
    1,274

    it just came across my mind that the BMS sensor...

    it just came across my mind that the BMS sensor is inside the blower compartment and it showing 35* in their monitor.

    this job is coming from our sales team that provided quoted job for compressor...
  11. Replies
    37
    Views
    1,274

    80 f after liquid dryer. return 73 supply right...

    80 f after liquid dryer.
    return 73 supply right after evap coil 35 degree
  12. Replies
    37
    Views
    1,274

    if there is superheat there will be no liquid...

    if there is superheat there will be no liquid right? aside from high head pressure when ambient reach 80 or more.
    with 55 ambient and 230 head pressure and 73 return I think suction pressure...
  13. Replies
    37
    Views
    1,274

    What they have done in the past is using garden...

    What they have done in the past is using garden hose and spray mist the condenser Coil. Sort of watering your grass at home When outdoor above 90* f.
    there is a lot of scale damaged on the fins.
    ...
  14. Replies
    37
    Views
    1,274

    The condition of the condenser Coil is bad....

    The condition of the condenser Coil is bad.
    deteriorated fins. This unit 30 + years old.
    I think that's 230 psi is considered OK
  15. Replies
    37
    Views
    1,274

    its R-22 . after compressor changed did weight in...

    its R-22 . after compressor changed did weight in 10.5 lbs as name plate.
    pressurized the cap tube from opposite direction just to clear anything there and flushed out oil.
  16. Replies
    37
    Views
    1,274

    compressor carrying the oil out as fast as it's...

    compressor carrying the oil out as fast as it's coming back.

    that really make sense in this case , i need to drain some oil. thanks
  17. Replies
    37
    Views
    1,274

    no head control on this carrier. it should...

    no head control on this carrier. it should economizing for sure.
  18. Replies
    37
    Views
    1,274

    there is no evident of frost on all cap tube . ...

    there is no evident of frost on all cap tube .
    this unit runs like walk in cooler now. if its not because of anti ice switch it will iced up the compressor.

    checked blower speed rpm is well...
  19. Replies
    37
    Views
    1,274

    its 8 capillary tube with header. oil level full...

    its 8 capillary tube with header. oil level full at sight glass.
    during start up head pressure fluctuate up to 320 psi and back to 230 psi after a minute or so.

    i suspected the oil in evaporator...
  20. Replies
    37
    Views
    1,274

    too much oil lodging in evaporator coil?

    replaced compressor on old carrier unit COPELAND BRE2-0750-TFC-904 to ZR94KCE-TFE-950.
    the original compressor failed both suction and head pressure equalize and runs like that for 2 years. no...
  21. Replies
    7
    Views
    2,168

    Have you find the culprit? I have similar case...

    Have you find the culprit?
    I have similar case where flame failure a few times a week.
  22. Replies
    6
    Views
    692

    your theory are excellent, my problem is bad...

    your theory are excellent, my problem is bad connection at harness connector to hi limit.
    with clean 24V it sparking perfect.

    many thanks Mr.
  23. Replies
    6
    Views
    692

    Did installed ground wire from electrode screw to...

    Did installed ground wire from electrode screw to clean solid ground .
    No spark at all. I can see the electrode if it does sparking.
  24. Replies
    6
    Views
    692

    No common just ground terminal. Yes travel...

    No common just ground terminal.
    Yes travel through series of safety and ending powered the module.
    Did jump the rollout switch and pressure switch but no effect.
    I'll try it with clean 24v...
  25. Replies
    6
    Views
    692

    Igniter will not spark issue Lennox LGA120

    LENNOX RTU M #LGA120SH1J S # 5697H03406

    having issue with igniter won't spark. LED BLINK 6 HARWARE FAULT DETECTED.
    DIRECT SPARK IGNITER
    Ignition module terminal MV/POWER/FS/GROUND.
    ...
  26. Replies
    13
    Views
    1,205

    [QUOTE=BBeerme;18929931]Can you get tonnage off...

    [QUOTE=BBeerme;18929931]Can you get tonnage off of the TEV's?

    measure the orifice. That'll give you a pretty big clue to the tonnage.
    no more Data on the TXV head. measuring orifice is way to go...
  27. Replies
    13
    Views
    1,205

    its not the same. I think an older 240RA series. ...

    its not the same. I think an older 240RA series. don't understand the numbering valve body R0404 1 240RA-H9 represent.
    liquid pipe 7/8. my guessing is about 25-50 ton capacity. an older carrier...
  28. Replies
    13
    Views
    1,205

    took it apart and there is damaged valve seat.

    took it apart and there is damaged valve seat.
  29. Replies
    13
    Views
    1,205

    solenoid valve replacement help

    could not find specs on this solenoid valve. this number from valve body R0404 1 240RA-H9.
    looking for tonnage capacity.
    leaky solenoid need replacement.

    coil specs Emerson R0607 AMG 120v 17...
  30. 06D series compressor, some have solenoid...

    06D series compressor, some have solenoid capacity control and some has pressure actuated capacity control.
    its hard to tell if the tone change if all other compressors runs at same time.
    amperage...
  31. how to check pressure actuated unloader on Carlyle compressors.

    never work on pressure actuated Unloader before, how it work and how to check if its loading or unloading!
  32. Thread: Ypal schematics

    by cfe
    Replies
    4
    Views
    436

    Hi YORKAPPRENTICE, having trouble with this...

    Hi YORKAPPRENTICE,

    having trouble with this unit have no respond to keypad. their is password on the panel 9725 but I don't know how to enter it.

    display showing
    Version A09
    Address 32...
  33. Replies
    3
    Views
    931

    Hi Pete Mccarthy, I have 9725 written on the...

    Hi Pete Mccarthy,

    I have 9725 written on the panel but I don't know which button to enter the password. I have tried all button none is responding.

    display shown
    Version A09
    Address ...
  34. Replies
    15
    Views
    1,610

    27 volt secondary transformer, 24 volt back to...

    27 volt secondary transformer, 24 volt back to rooftop with jumper at thermostat.
    even 17 Volt with Nest , on call for cool did not witness any chatter at all and could last more than a month until...
  35. Replies
    15
    Views
    1,610

    there is dispute between the landlord ant the...

    there is dispute between the landlord ant the tenant regarding who's at fault and bill to.

    need solid prove that the Nest thermostat indeed is the problem.
    tenant stated that they installed Nest...
  36. Replies
    15
    Views
    1,610

    any other Nest thermostat problem reported?

    an office just installed Nest thermostat them self 3 months ago and its took out the compressor Contactor (welded). changed out the contactor 2 months ago.
    today back with same problem plus...
  37. Replies
    14
    Views
    1,293

    it was set by Hussmann local distributor who have...

    it was set by Hussmann local distributor who have the original contract with the store.
    we are not allowed to change any setting. sort of sub contractor for this store.

    was told that 10 ppm is...
  38. Replies
    14
    Views
    1,293

    how big is 10 ppm leak? can not find the leak

    leak detections system at supermarket set at 10 ppm leak, 100 ppm spill, 300 ppm evacuate. R-22 system.

    inside the walk in cooler where one of the zone air sample filter located pick-up 12 ppm...
  39. I did and the problem is leaking at Hydrophobic...

    I did and the problem is leaking at Hydrophobic filter. replaced the filter and seems runs good.
  40. thanks for the link, the model is different from...

    thanks for the link, the model is different from the one i'm dealing with HGM-MZ . are they pretty much the same way of diagnostic?
  41. feeling the suction directly from the pump it...

    feeling the suction directly from the pump it sucking good. don't remember the actual psia reading in diagnostic screen.
    system temporary disabled.
  42. BACHARACH HGM-MZ HALOGEN GAS MONITOR NO FLOW PROBLEM !!!

    refrigerant leak monitoring systems with 16 zone keeps going into alarm every 15 min.

    alarm fault code 0800 no flow zones on multiple zones. it will cleared itself next sampling cycle but...
  43. No, I'm talking about 24 V fuse on control board....

    No, I'm talking about 24 V fuse on control board. the unit it self 575 Volt with 40 amp breaker.

    I would install resettable fuse till found the problem.
  44. Replies
    9
    Views
    1,555

    recently have similar problem, Eng-A MUA shut...

    recently have similar problem, Eng-A MUA shut down intermittent. customer reset it by on/off breaker and back to normal for about 30 min and shut down again.
    flame failure error, clean the flame...
  45. had the same problem with carrier rooftop unit,...

    had the same problem with carrier rooftop unit, found shorted 24 volt control wire to economizer wounded to chassis that intermittent blowing 5 amp fuse. had to move the top panel to see it.
  46. Replies
    86
    Views
    10,002

    JP, what temp expected for a good separator?...

    JP, what temp expected for a good separator? should it be slightly lower than discharge temp?
  47. Replies
    10
    Views
    734

    Glad your on board, have you work on engineered...

    Glad your on board,
    have you work on engineered air model#FWB-182/DJ-60-CO I think is made in your City, Edmonton.

    421151421161421151421161

    did maintenance few days ago but have no idea how...
  48. Thanks for all inputs, Leak check entire system,...

    Thanks for all inputs,
    Leak check entire system, electronic leak detector doesn't pickup anything. No oil residue present.

    If this is original charge then it survived last winter. If there is...
  49. I thought 80% is total charged, mean nothing in...

    I thought 80% is total charged, mean nothing in condenser and liquid line.

    some condensing unit i have seen with LAC have label that add certain amount of lbs after clear sight glass.

    in this...
  50. it could go down to 0 - 10* F in winter the...

    it could go down to 0 - 10* F in winter

    the cooler fairly new, installed in 2011 by other company.
Results 1 to 50 of 164