Search:

Type: Posts; User: jeffinok

Search: Search took 0.00 seconds.

  1. Replies
    9
    Views
    1,131

    if it was hooked up and sealed properly the 14 in...

    if it was hooked up and sealed properly the 14 in flex is still only good for 2 1/2 tons of air .
  2. Replies
    33
    Views
    5,488

    the horizontal drain pan is at the top the drain...

    the horizontal drain pan is at the top the drain is coming out of the vertical pan
  3. Replies
    30
    Views
    5,325

    i would tell him to call me when hes ready for a...

    i would tell him to call me when hes ready for a new furnace . i wouldnt want to be responsable
    for that hacked up mess!!
  4. Replies
    65
    Views
    6,146

    my new favorite tool is a hydrualic swaging tool....

    my new favorite tool is a hydrualic swaging tool. makes fitting and sweating copper alot easier.
    only one joint to sweat instead of two with a coupling ..
  5. Replies
    19
    Views
    1,010

    i gave myself a new dewalt heated jacket ... ...

    i gave myself a new dewalt heated jacket ... its warm!!!!:grin2:
  6. Replies
    16
    Views
    1,686

    i like the klein 612-4 1/8" Terminal Block...

    i like the klein 612-4 1/8" Terminal Block Screwdriver also it has the small tip for working on thermostats but it has a regular size handle . much better to keep my hands from cramping up...
  7. Replies
    5
    Views
    693

    three phase compressures will run backwards for a...

    three phase compressures will run backwards for a short time . i know this from doing startups .
    you have to check for proper rotation on three phase the first time you start up a unit. just...
  8. my vacuum pump wouldnt pull below 576 on my...

    my vacuum pump wouldnt pull below 576 on my micron gauge .
    i tried what the guy did in the last post here ...
  9. Thread: 30 + 30= 60??

    by jeffinok
    Replies
    41
    Views
    2,750

    thanks for the replys. i know in series what...

    thanks for the replys.
    i know in series what ever two you combine halves it . just wanted to make sure i could mix and match uf ratings in parrallel . again thanks
  10. Thread: 30 + 30= 60??

    by jeffinok
    Replies
    41
    Views
    2,750

    question on the subject. i was told when you...

    question on the subject. i was told when you parrallel two capacitors they must be the same uf .
    example 10+10=20 . said you couldnt put a 10uf with another uf rated cap such as a 5uf? is this...
  11. Replies
    41
    Views
    6,636

    doesnt anybody run metalpipe anymore? instant...

    doesnt anybody run metalpipe anymore? instant pipe in a bag .
    glad thats not going in my house:Faint:
  12. Thread: hello

    by jeffinok
    Replies
    5
    Views
    374

    thanks for the welcome . i have wired new units...

    thanks for the welcome . i have wired new units , pulled copper , checked roof tops on start ups ,adjusted belts checked pullys under the supervision of a service tech on a multiple unit start up ...
  13. Thread: Snips

    by jeffinok
    Replies
    17
    Views
    1,201

    as stated midwest seems to hold up the best for...

    as stated midwest seems to hold up the best for me. i have tried malco wiss and several others over the years .
  14. Thread: hello

    by jeffinok
    Replies
    5
    Views
    374

    hello

    hello, my name is jeff . i have been fabricating and installing commercial sheetmetal jobs for the last 16 years . i would like to do service . i know the basics of the systems just not the details....
  15. im glad i had the priviledge of working with an...

    im glad i had the priviledge of working with an old school sheetmetel worker for my first 6 years . i have been doing sheet metal for 15 years now . just getting into service . theres no book i have...
  16. if i didnt know the person i was buying it from i...

    if i didnt know the person i was buying it from i wouldnt.
    i need to trust my meter . you make your living with this and use it every day if you spend $ 96 and not everything works you now have to...
  17. Replies
    12
    Views
    2,332

    wow is all i can say!!!! that coil is definately...

    wow is all i can say!!!! that coil is definately choked on air flow . it looks like they had plenty of clearance around
    the coil and furnace to do it right.
  18. Replies
    6
    Views
    1,763

    i have made replacement doors out of sheetmetal...

    i have made replacement doors out of sheetmetal never tape :gah:.

    dont they know your supposed to use duct tape not fsk? :gah::bump::grin2: lol
  19. Replies
    7
    Views
    1,759

    more return is an understatement. poor blower...

    more return is an understatement. poor blower motor is starving
  20. Replies
    7
    Views
    1,191

    might want to check your local codes . ductwork...

    might want to check your local codes . ductwork run in an unconditioned space isnt up to code around here.
  21. Replies
    38
    Views
    8,064

    midwest offsets are my favorite . have tried many...

    midwest offsets are my favorite . have tried many over the last 16 years
Results 1 to 21 of 22
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event