  1. Replies
    1
    Views
    69

    Should be an easy fix for your son the HVAC guy....

    Should be an easy fix for your son the HVAC guy. We are prohibited from DYI. There are lethal voltages in that air handler. I'm sure your son can walk you thru it.
  2. Replies
    77
    Views
    1,558

    Trump has mentioned this tonight during his Tampa...

    Trump has mentioned this tonight during his Tampa rally. This country needs to tax incoming products.
  3. Wait until the weather is in the 80's and have a...

    Wait until the weather is in the 80's and have a good knowledgeable tech check the charge in cooling. FYI, one person's thermometer may read slightly different than someone else's. That is why we are...
  4. Replies
    2
    Views
    126

    Naima has them. Just use google. John's manville...

    Naima has them. Just use google. John's manville also has them.
  5. Replies
    6
    Views
    332

    I have been using the black vacuum rated hoses...

    I have been using the black vacuum rated hoses with the Uniweld quick disconnect with the bearing in it. The jury is still out. The Ritchie Yellow Jacket ends have been troublesome.
  6. Replies
    5
    Views
    314

    check all wires carefully for a rub thru. You...

    check all wires carefully for a rub thru. You could also put a smaller fuse inline with each wire and see which one blows.
  7. Replies
    4
    Views
    279

    I use mastic at the junction of the inside of the...

    I use mastic at the junction of the inside of the flex with a panduit strap, then bring the outer insulation and silver mylar to the junction of the duct board. I secure this with a panduit strap...
  8. Replies
    3
    Views
    248

    different capacitors for different HP

    different capacitors for different HP
  9. Replies
    4
    Views
    231

    The better contractors do Manual J and S when...

    The better contractors do Manual J and S when replacing equipment.
  10. You should have taken a cell phone photo of the...

    You should have taken a cell phone photo of the before wiring. When you signed up for the forum, it said ' "No DYI". We are not permitted to help you wire your unit due to liability issues. You have...
  11. Replies
    165
    Views
    5,891

    The Bluvacs can take a hit of pressure without...

    The Bluvacs can take a hit of pressure without damage.
  12. Replies
    44
    Views
    1,179

    Might have a fan blade slipping on the hub.

    Might have a fan blade slipping on the hub.
  13. Replies
    19
    Views
    1,015

    When I change a motor, sometimes I say to myself...

    When I change a motor, sometimes I say to myself that the new one won't last as long as the old capacitor. Sad but true.
  14. Rick, Check your yahoo account for email

    Rick,
    Check your yahoo account for email
  15. Rickteh, it would be easier on us if you only...

    Rickteh,
    it would be easier on us if you only had one post on this problem instead of multiple posts. What is the model number?
  16. And when you brazed the TXV's in, you flowed N2...

    And when you brazed the TXV's in, you flowed N2 right? And you purged the system with N2 when you had the TXV's off, right?
  17. Measure temps before and after check valve. Also...

    Measure temps before and after check valve. Also measure temps across TXV. Pull TXV bulb loose and see if warm/cool test changes gauge readings.
  18. Replies
    165
    Views
    5,891

    Even though Bluvacs can take a 400 to 500 psi...

    Even though Bluvacs can take a 400 to 500 psi pressure, I use a core tool inline with the micron gauge. This way, I can shut the core tool off to protect it. I do not use schraders when pulling...
  19. Replies
    165
    Views
    5,891

    I received it little guy today. I made a jig to...

    I received it little guy today. I made a jig to test it against my first Bluvac and the Ritchie yellow Jacket 69075. My jig was an empty refrigerant jug that I drilled 3 holes in the side and...
  20. Replies
    31
    Views
    793

    I am also getting notices that my blocker is...

    I am also getting notices that my blocker is doing its job. It is a trojan
  21. I used MO99 with no problems so far. I changed...

    I used MO99 with no problems so far. I changed the drier and almost used R407c until I came across the oil problem which was mineral oil. I called the manufacturer and they said no on using mineral...
  22. When you use 407c you have to change the oil to...

    When you use 407c you have to change the oil to POE.
  23. Replies
    165
    Views
    5,891

    I would perfer to put a few schrader caps in...

    I would perfer to put a few schrader caps in there. that way, you will always have them handy.
  24. Replies
    5
    Views
    366

    Just make sure you use a software rated for...

    Just make sure you use a software rated for commercial. A residential software will not work. you'll have lighting,ventilation,scheduling,door traffic,and occupancy loads to take into consideration.
  25. For those thinking about Elite, contact John...

    For those thinking about Elite, contact John Walsh at tftt@tftt.org. He has a book with photos that explains EVERY input and detail of Elite. I use Wrightsoft. I am staying with Wrightsoft only...
  26. Replies
    165
    Views
    5,891

    Jim I stopped by and you showed me the new toy...

    Jim I stopped by and you showed me the new toy you had.
  27. I have to correct myself. I checked with both...

    I have to correct myself. I checked with both Fieldpiece and Bacharach at the AHR show and I am in error. Bacharach does not make the SLR2 infared for Fieldpiece. Fieldpiece at one time copied the...
  28. Replies
    37
    Views
    5,472

    The Fieldpiece SLR8 works well with R410. It is...

    The Fieldpiece SLR8 works well with R410. It is not to good on R22. It is a heated diode type and uses sensors every couple of years depending upon usage. The new H10's are super-sensitive for R410.
  29. Replies
    4
    Views
    298

    If you studied, you'll be fine. Relax and have a...

    If you studied, you'll be fine. Relax and have a good night's rest. I hated the material but finished way early and scored 92+
  30. booth number?

    booth number?
  31. And who do you all think makes the Fieldpiece...

    And who do you all think makes the Fieldpiece leak detectors? Yep, Bacharach.
  32. Yes, you may be missing the point. Some...

    Yes, you may be missing the point. Some installers do not purge nitrogen thru the lines while brazing. nitrogen prevents the forming of black sludge deposits from forming inside the pipes. They also...
  33. Replies
    10
    Views
    298

    Trane at the present time is the only...

    Trane at the present time is the only manufacturer (same as American Standard) that has an air handler that is built like a refrigerator and will not sweat. So if you are installing the air handler...
  34. Replies
    2
    Views
    232

    Please disregard. I found it. Thanks anyway.

    Please disregard. I found it. Thanks anyway.
  35. Replies
    2
    Views
    232

    Rundawg, Do you have this one?

    Carrier electronic air cleaner. It is an older one model 31RX01610

    TIA
  36. Thread: Self report

    by Gunslinger
    Replies
    27
    Views
    2,124

    If you're real particular like me, try rubbing...

    If you're real particular like me, try rubbing compound. If that won't work, buy a can a spray paint from Trane. Get a scuff pad and touch it up. Problem solved until the next time.
  37. Replies
    165
    Views
    5,891

    Accutools is the most customer friendly supplier...

    Accutools is the most customer friendly supplier I have ever run across. This item appears to be another winner. I can not get to AHR fast enough.
  38. Carrier, Bryant, Tempstar, Eco-Temp, Heil, Day...

    Carrier, Bryant, Tempstar, Eco-Temp, Heil, Day and Night, Payne, Comfortmaker, and a bunch more are owned by the same parent company. Carrier has some higher end equipment along with Bryant. These...
  39. Replies
    3
    Views
    562

    Just go to their website and search for it.

    Just go to their website and search for it.
  40. Replies
    3
    Views
    562

    New Fluke 902

    I see it is bluetooth. They increased the resistance range to read 60K full scale but that is not enough for testing ECM motor windings to ground. Genteq wants 100K to ground.
  41. that is not normal. Call a service tech.

    that is not normal. Call a service tech.
  42. Replies
    1
    Views
    234

    You should be ok with 6 feet

    You should be ok with 6 feet
  43. Replies
    14
    Views
    1,120

    Fluke 902 does not have a good resistance range....

    Fluke 902 does not have a good resistance range. 10K is not enough to test ECM motor windings for grounds and leakage to ground. You need at least 100K
  44. Replies
    11
    Views
    427

    Your system has one muffler located in the...

    Your system has one muffler located in the discharge line of the compressor. You had 2 liquid driers inside the unit that can be removed and replaced by a biflow drier in the liquid line. The...
  45. Replies
    11
    Views
    427

    If you give me model number and serial, I can...

    If you give me model number and serial, I can look up the system's layout.
  46. original poster....give the model and serial...

    original poster....give the model and serial numbers of both units.
  47. Just tell him your whole story and let him find...

    Just tell him your whole story and let him find it.
  48. Replies
    3
    Views
    249

    Does the unit purge water when the purge switch...

    Does the unit purge water when the purge switch is pressed? IF not, looke at the high temp sensor switch. You can short it out for testing.
  49. Replies
    4
    Views
    317

    I realize your frustration however we can not see...

    I realize your frustration however we can not see your system from a keyboard. The model number you stated is an air handler. The outside unit is referred to as a heat pump. If you have the proper...
  50. I believe the new Tempstar evaporators are...

    I believe the new Tempstar evaporators are aluminum coils. The Trane air handler is the composite case built like a refrigerator. They do not sweat. They have aluminum coils on the evaporators also....