Search:

Type: Posts; User: Tex76

Search: Search took 0.00 seconds.

  1. Thread: GE Refrigerator

    by Tex76
    Replies
    7
    Views
    719

    GE Refrigerator

    I had a friend give me a small GE Refrigerator that He said is low on 134A. I was going to try to get it running. I am a residential guy so I thought I would ask the refrigeration experts. What...
  2. Replies
    13
    Views
    1,223

    Again it is most likely is the defrost board bad....

    Again it is most likely is the defrost board bad. Get a professional out to make the repair. The coil iced up indicates the unit not going into defrost mode. if the defrost clamp on stat is made...
  3. Thread: my first child

    by Tex76
    Replies
    34
    Views
    2,115

    Congratulations! I have 2 boys 5 and 2. They...

    Congratulations! I have 2 boys 5 and 2. They are the joy of our life! Many good times to come! Cherish each moment time goes by too quick!
  4. Replies
    13
    Views
    1,223

    I agree with armament, but I would also suspect...

    I agree with armament, but I would also suspect defrost t-stat, Defrost board, or both.
  5. Replies
    13
    Views
    1,955

    If I am pulling a vacuum through a 2-valve...

    If I am pulling a vacuum through a 2-valve manifold those two 1/4 inch hoses one to high-side one to low-side are pulling through the 1/4" port in middle of the manifold. So by using yellow jacket...
  6. You are right the reason that a by-pass damper is...

    You are right the reason that a by-pass damper is there is to circulate excess air of the blower output across the coil when only one or sometimes two zones are calling. You must have at least...
  7. Replies
    13
    Views
    1,955

    On the yellow jacket tree there are two 3/8...

    On the yellow jacket tree there are two 3/8 branch ends that go to the system. One going to high side 1/4 inch the other to the low side 1/4 inch. I will probably have to get two 1/4 inch hoses and...
  8. Replies
    13
    Views
    1,955

    I forgot to mention that I am working on getting...

    I forgot to mention that I am working on getting my posts up so I can be accepted into professional forum. I cant wait. I just have to get use to getting on the computer more. I tend to go to...
  9. Replies
    13
    Views
    1,955

    Do you use 3/8 by 1/4 metal hoses with the tree...

    Do you use 3/8 by 1/4 metal hoses with the tree to perform a blank off test because charging hoses will not hold a deep vacuum. You can pull a vacuum through charging hoses(manifold hoses) but cant...
  10. Replies
    14
    Views
    2,712

    I would request heat loss/gain calcs from both...

    I would request heat loss/gain calcs from both contractors. Compare unit outputs to loss/gain calcs of house load. This is to determine whether you need a 3 ton or 4 ton unit. You just want to...
  11. Replies
    11
    Views
    2,542

    In performance no difference between vertical vs...

    In performance no difference between vertical vs horizontal as long as designed properly. However the cost of the vertical will generally cost more due to drilling costs. You will be putting more...
  12. Replies
    13
    Views
    1,955

    Using 410A Guages and hoses for R-22?

    I am looking at speeding my vacuum time with replacing my 2-valve manifold with JB Zeppelin 4-valve manifold. This gives me a 3/8 port to evacuate with instead of 1/4 inch that chokes the flow. I...
  13. Replies
    29
    Views
    2,323

    I forgot to answer a question. I will assume I...

    I forgot to answer a question. I will assume I will be doing a little more ref. work in the future although my expertise is in HVAC and Geo-exchange residential. I do take pride in learning the job...
  14. Replies
    29
    Views
    2,323

    First of all I will apologize. I did not mean to...

    First of all I will apologize. I did not mean to say I was making a living and you guys are not I know that is not the case. Thank you for the help. I am sorry I have no more information for you...
  15. Replies
    29
    Views
    2,323

    sorry took so long to get back on-line. Been out...

    sorry took so long to get back on-line. Been out making a living. Ok I get it about just using the gauges I got and pt charts. I guess I just get my superheat back to compressor and the liquid sub...
  16. Make sure Honeywell Zone board in installer set...

    Make sure Honeywell Zone board in installer set up menu is set up were t-stats are controlling equip not time staging. May have to get the installer to do that.
  17. Replies
    29
    Views
    2,323

    Thank you every one for the advice. I will...

    Thank you every one for the advice. I will continue to learn from this experience. The condenser is outside and I did not want to put my dedicated 410A or R22 gauges on this system because I do not...
  18. Replies
    29
    Views
    2,323

    Yes I Liquid charged as the bottle directed. I...

    Yes I Liquid charged as the bottle directed. I did inform them that the leak needs to be found and repaired and we will do that in the future. If I continue to work on their refrigeration equip I...
  19. Replies
    25
    Views
    4,547

    No other way to cook! I have done it all in a...

    No other way to cook! I have done it all in a dutch oven. Biscuits, cakes, pies, stews, soups, oh and cobblers. I use a hanging hook system to control heat. The keys keep ovens cured, watch and...
  20. Replies
    29
    Views
    2,323

    Did I do it Right?

    We have been doing work for a hospital in our local area. It snowed 3 ft. they could not contact anyone. Their walk in Refrigerator was above 40 deg. They called me to come get it going. They...
Results 1 to 20 of 20
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event