    IFM/Compressor phenomenon: Marginal flow can...

    IFM/Compressor phenomenon: Marginal flow can cause rapid temperature change at flow switch probe when compressors start/stop = Flutter effect/Nuisance trips.
    Glycol? Installed flow switch (cm/sec)?...
  2. Replies
    8
    Views
    793

    I have seen this a few times on Intellipaks with...

    I have seen this a few times on Intellipaks with an LCI-I/Lon board being used for comm. If unit has LCI-I, Switch unit control mode from BAS to LOCAL and see if unit starts.
  3. Replies
    3
    Views
    1,275

    A C02 error/fault will not shut the unit down,...

    A C02 error/fault will not shut the unit down, Unless BAS has something to do with it.
  4. Replies
    12
    Views
    765

    Why not use hot gas bypass and a liquid receiver.

    Why not use hot gas bypass and a liquid receiver.
  5. Replies
    41
    Views
    4,165

    This would be a true statement if this unit was a...

    This would be a true statement if this unit was a RTAA.

    graham,
    YOU SHOUTED OUT LOUDLY ABOUT THE FUNCTION OF THE GLASS, BUT YOU MISSED SUMTIN!
    The glass also indicates moisture. :D
  6. Replies
    41
    Views
    4,165

    Circuit charge can be checked with full load...

    Circuit charge can be checked with full load conditions and subcooling chart for tonnage/efficiency(standard,high) of that circuit. With a dropping film flooded type evaporator, Charge could be way...
  7. Replies
    37
    Views
    2,351

    :eek:

    :eek:
  8. Thread: CVHF

    by jimbob73
    Replies
    40
    Views
    2,521

    Yes, With dynaview/CH530, You need techview to...

    Yes, With dynaview/CH530, You need techview to service temperature sensors/pressure transducers or to operate devices manually like IGV, starter, etc.... This software is free and can be dowloaded...
  9. Thread: CVHE 650

    by jimbob73
    Replies
    27
    Views
    1,524

    Flows are incorrect, Crap load of oil in...

    Flows are incorrect, Crap load of oil in refrigerant/evaporator, Not enough flow, Glycol present, Hijacking "failure to accelerate thread" etc.........
  10. Thread: 5 ton RTU

    by jimbob73
    Replies
    18
    Views
    2,034

    Did you wash out in between the coils?

    Did you wash out in between the coils?
  11. Thread: CVHE 650

    by jimbob73
    Replies
    27
    Views
    1,524

    It can't be that easy, Although it seems 9 out of...

    It can't be that easy, Although it seems 9 out of 10 times it is. The 1 time it's not is when hairs start turning gray and hair loss increases.
  12. Replies
    46
    Views
    4,354

    It is an engineer designed hail guard for that...

    It is an engineer designed hail guard for that unit. If it can work on a piece of paper, then it will work on the unit. A classic example of how what is drawn on paper does not always work as well in...
  13. Thread: vacuum gauge

    by jimbob73
    Replies
    11
    Views
    1,008

    I really like the Inficon leak detectors, But the...

    I really like the Inficon leak detectors, But the Inficon vacuum gauge I don't care for. Been happy with my yellow jacket vacuum gauge.
  14. Thread: CVHF

    by jimbob73
    Replies
    40
    Views
    2,521

    T.O. makes things more interesting everywhere he...

    T.O. makes things more interesting everywhere he goes! I was gonna get rid of NFL Sunday ticket because the price of it is getting rediculous, But the BILLS keep finding ways to keep me paying for...
  15. Replies
    9
    Views
    1,478

    I agree with ascj, A remote panel with NSB (night...

    I agree with ascj, A remote panel with NSB (night setback) was used for setback control of the unit and I doubt they are still available.
  16. Thread: CVHF

    by jimbob73
    Replies
    40
    Views
    2,521

    It should have the new style economizer flanges? ...

    It should have the new style economizer flanges?
    If so, Silicon bead faces bolt heads, Torque in star pattern, 30 ft lbs then 55 ft lbs.
  17. Replies
    9
    Views
    927

    Plate and frame?

    Plate and frame?
  18. Replies
    9
    Views
    1,103

    I have replaced a few of em due to that. There...

    I have replaced a few of em due to that. There was a very rare problem with shaft/packing alignment on some of the suction butterfly valves. Only fix is to replace the entire butterfly valve.
  19. Replies
    24
    Views
    1,990

    An EBS guy in our office sent me those chiller...

    An EBS guy in our office sent me those chiller and CTV videos sometime back in November and that has been the only email I havn't deleted.


    About the bills and being in the midwest. I was born...
  20. Replies
    24
    Views
    1,990

    Here is another one for the CTV, Funny suff! :D ...

    Here is another one for the CTV, Funny suff! :D

    http://www.youtube.com/watch?v=_31uAoXzG7A&feature=related
  21. The Trane part number for that board is BRD00621....

    The Trane part number for that board is BRD00621. The factory no longer has it and there is no replacement available. You could try a electronics repair establishment or ebay. I heard of people...
  22. Thread: just curious

    by jimbob73
    Replies
    9
    Views
    625

    You guys can give me all the copper tubes, I'll...

    You guys can give me all the copper tubes, I'll get rid of them for ya! ;)
  23. Replies
    27
    Views
    2,446

    Simple Green, Then a pre moistened alcohol towel...

    Simple Green, Then a pre moistened alcohol towel just before assemply.
  24. Replies
    25
    Views
    3,803

    If you want to get technical, There is software...

    If you want to get technical, There is software that can be installed on a computer that can be hooked up to an Intellipak, It's called Tracer Summit! ;)

    I agree with graham, Post what active...
  25. Replies
    6
    Views
    616

    It hasn't done much good lately because a...

    It hasn't done much good lately because a majority of the PDF files are corrupt. Hopefully it will be fixed some time soon.
Results 1 to 25 of 284
Page 1 of 12 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event