    Well, looking at the picture I see BX cable, not...

    Well, looking at the picture I see BX cable, not MC so the armor serves as the ground. Hence the reason for no green wire in the cable and the presence of the bonding wire, meant to keep the armor...
  2. Replies
    4
    Views
    933

    New RTU Annoyances and A Rant

    Rant On,

    Just installed a new 20 Ton Trane Voyager. I go to start it up and found circuit 2 flat. Checked condensor and found a large leak at the bottom just past the u bend at the tube sheet. A...
  3. This sounds like a logical approach. The LCI-R...

    This sounds like a logical approach. The LCI-R interface is readily available for the Reliatel and the other units could easily be controlled by lon t'stats.

    Any preference between Echelon I-Lon...
  4. Are these custom units with the operation for...

    Are these custom units with the operation for process?
    They are not custom units
    Do you need OPC for their SCADA system (if they have this)?
    They don't have a SCADA system.
    Do you prefer a local...
  5. Suggestions for light industrial HVAC control system

    I am looking for some suggestions for HVAC control systems for a small factory. They are looking to have control of all the systems from one place and limited operator control locally (like the...
  6. Thread: MEATLOAF

    by txvsrule
    Replies
    10
    Views
    2,236

    I got the recipe from a radio show about 3 years...

    I got the recipe from a radio show about 3 years ago. It's the best I've ever had.

    Italian meat loaf

    2 pounds lean ground sirloin
    1 cup Italian bread crumbs
    2 eggs beaten
    Salt and pepper to...
  7. Replies
    8
    Views
    1,545

    5 gallons of oil, holy sh't. NewportNic is...

    5 gallons of oil, holy sh't.

    NewportNic is right if you are lucky. Remove every last bit of lithium-bromide and water. Ask the factory for a 'recomended degreaser', nice clean rust free steam...
  8. Replies
    213
    Views
    11,746

    Oddly enough I understand exactly what you are...

    Oddly enough I understand exactly what you are saying. I am assuming that the 6cph setting is not requiring the furnace to shut down every 10 minutes, but not allowing it to cycle any shorter than 10...
  9. Replies
    213
    Views
    11,746

    Regarding humidity, I have no humidifier of any...

    Regarding humidity, I have no humidifier of any sort. I really do need one or two desperately though. In my situation given the longer run times on the air handlers, even though the air handlers...
  10. Replies
    213
    Views
    11,746

    In my own home I had 2 comfortmaker single stage...

    In my own home I had 2 comfortmaker single stage furnaces 80% with a total btu output of 250,000 btu. They were replaced with a hydro-air system utilizing a mod-con boiler with a max output of...
  11. Replies
    103
    Views
    8,390

    A Jewish Deli Sloppy Joe- Corned Beef, Pastrami,...

    A Jewish Deli Sloppy Joe- Corned Beef, Pastrami, Turkey, Roast Beef on Triple Decker Rye Bread With Russian Dressing And Coleslaw on the sandwich and a pickle on the side with some greasy fries...
  12. Replies
    5
    Views
    556

    The only ill effects I have ever seen because of...

    The only ill effects I have ever seen because of the heating coil being on the return were on resi ECM motors, but this doesn't apply here. It should be fine. The only thing you'll be heating is the...
  13. Replies
    13
    Views
    3,954

    Nope that's no mis-application they probably have...

    Nope that's no mis-application they probably have 208v 3~ and are looking for 220V.

    http://www.solaheviduty.com/products/transformers/pdfs/bboost/bbselect3ph.pdf

    Depending on the type of 3~,...
  14. Replies
    10
    Views
    1,216

    Do a search on my screen name, I responded in...

    Do a search on my screen name, I responded in detail a while ago to another person asking the same question. In my opinion the Aprilaire t'stat stinks. It's compensation programming is way to loose...
  15. Thread: DV Gas Insert

    by txvsrule
    Replies
    2
    Views
    857

    DV Gas Insert

    I have a Majestic WMC42 wood burning fireplace in my own home. This was installed and surrounded on all sides by full thickness brick. At some point a set of gas logs were installed. The fire looks...
  16. Replies
    4
    Views
    668

    You probably have an ARKLA/SERVEL/ROBUR. That is...

    You probably have an ARKLA/SERVEL/ROBUR. That is not the condensor loop that has the brine in it. It is the chilled water loop and unless you want to freeze the unit in the winter, it takes a...
  17. Replies
    23
    Views
    6,051

    Yeah, The Federals are bad, between arcing of the...

    Yeah, The Federals are bad, between arcing of the bus and non-trips they really stink, the later breakers are supposed to be a little better in the trip dept, but the bus bar has to be real clean and...
  18. Replies
    2
    Views
    629

    They are there to provide a small amount of power...

    They are there to provide a small amount of power between the W1 & R and W2 & R even when the limits are open for power stealing thermostats or older electronic thermostats that use triacs for...
  19. Replies
    21
    Views
    2,819

    Show me a clean room that uses electronic air...

    Show me a clean room that uses electronic air filters only, in a similar arrangement to a home EAC, with just a small 1" pre-filter and no other filtration.
    You will never see this.

    However you...
  20. Replies
    21
    Views
    2,819

    If humidity is not an issue then the UV lights...

    If humidity is not an issue then the UV lights are really not needed. I feel strongly against electronic air filters, as I've seen too many that weren't cleaned properly shut down and allow all the...
  21. Replies
    21
    Views
    2,819

    Agreed, get any 5" Pleated Media filter. The...

    Agreed, get any 5" Pleated Media filter. The problem with electronic filters is that they are high maintenance and their efficiency drops as they get dirty, to the point where they shut down no...
  22. You say that you are in Central NJ and have...

    You say that you are in Central NJ and have perimeter ducts in a slab. The majority of houses like this I've seen have ductwork that doesn't lend itself well to central air. (I'm not saying it won't...
  23. Replies
    3
    Views
    710

    Get the Burner manual for the Powerflame from...

    Get the Burner manual for the Powerflame from their website. They have good troubleshooting and set-up instructions. Check your flame sensor for dirt. Check to make sure on startup that your air...
  24. Replies
    10
    Views
    809

    Being that it is a Weil McClain, Series 88 I...

    Being that it is a Weil McClain, Series 88 I imagine, it probably has the pressure switches in a tap in the front of the boiler. The way the pressure switches are mounted stinks. If you remove all...
  25. Replies
    14
    Views
    2,954

    I think that water heater is a Tragesser Coppper...

    I think that water heater is a Tragesser Coppper Core. Those tanks were copper lined and lasted just about forever.