  1. Replies
    9
    Views
    1,285

    But you have stated/repeated: So...

    But you have stated/repeated:





    So strking the word "incredibly" from Sunteq's assertion and you would appear to be in complete agreement. Even we include the descriptive term "incredibly"...
  2. Replies
    9
    Views
    1,285

    No one has stated in this thread that two...

    No one has stated in this thread that two compressors are the norm.

    What Sunteq does unambiguously state at the url I sited is that they use (eg) five tons of coil for a two-ton unit a 2.5:1...
  3. Replies
    9
    Views
    1,285

    So -- keeping it in perspective -- Is the/your...

    So -- keeping it in perspective -- Is the/your answer "Yes" for standalone water-to-water units ? ;-)



    Here is a GSHP manufacturer using coils rated at 5 tons for 2-ton units and two 5-ton...
  4. Replies
    9
    Views
    1,285

    "Somewhat forgiving" is one matter. It would seem...

    "Somewhat forgiving" is one matter. It would seem to me that more than _doubling_ the water coil size as at least one geothermal manufacturer has done is quite another matter -- especially in the...
  5. Replies
    9
    Views
    1,285

    Oversized water coils and superheat

    Several manufacturers now advertise over-sized water coils, including for water-water units, as a feature that increases efficiency.

    How is this done and still keep the superheat within the...
  6. Replies
    13
    Views
    8,572

    Answering my own question: ...

    Answering my own question:

    http://www.multiaqua.com/

    Any others?

    Thanks ... Marc
  7. Replies
    13
    Views
    8,572

    And most of what I've seen are floor-mounted...

    And most of what I've seen are floor-mounted consoles that look straight out of a 1960's government office building .... Can you steer me to a low-sone, high-mounting, unit that has a hand-held...
  8. Replies
    13
    Views
    8,572

    Ground-loop efficiencies for Heat Controller's...

    Ground-loop efficiencies for Heat Controller's Comfort-Aire new HWW Series Water-to-Water Systems don't look so good once one realizes that they have the data for ground-water and ground-loop...
  9. Replies
    13
    Views
    8,572

    Thanks for the prompt reply. DX is not an...

    Thanks for the prompt reply.

    DX is not an option (I'm a hydrogeologist and that much refrigerant in the ground gives me the willies ...). A water well was drilled for open-loop but it failed to...
  10. Replies
    13
    Views
    8,572

    Ductless (multi-split) geothermal (GSHP) ?

    Historic house is three-story, 180-years-old, solid brick interior and exterior walls with installed (some badly) ducts. Low-R envelope and resulting high energy $ has driven us toward 9-ton,...