  1. Replies
    7
    Views
    480

    I'm trying to do the batch edit of proxy points...

    I'm trying to do the batch edit of proxy points to change all the point IDs for example HP_01_01 to HP_01_02 as I copy folders but The replace function is unavailable in the point manager. Am I...
  2. Replies
    11
    Views
    337

    The points should show up in discovery. The...

    The points should show up in discovery.

    The points you need:
    Air Flow Maximum AV-47
    Air Flow Maximum Heat AV-46
    Air Flow Minimum AV-42
    Air Flow Minimum...
  3. Replies
    1
    Views
    181

    Intellipak is a device type 44. It would be a...

    Intellipak is a device type 44. It would be a different link as the TIMs if you still have other units on that link so it would require a different cable.
  4. Replies
    14
    Views
    963

    Without being connected to a controller I can't...

    Without being connected to a controller I can't see the screens to direct you exactly where to go but look in the configuration menu. Depending on your screen resolution, the load and save buttons...
  5. Replies
    14
    Views
    963

    The cable probably needs the other handshaking...

    The cable probably needs the other handshaking pins connected. A full 9 to 9 pin may be necessary.
  6. Replies
    14
    Views
    963

    Read all documentation available. There should...

    Read all documentation available. There should be no licensing required for the software.

    Connect to the original controller first, it should find it and tell you what you are connected to, then...
  7. Replies
    14
    Views
    963

    You need Trane Techview software: ...

    You need Trane Techview software:

    http://www.trane.com/commercial/north-america/us/en/controls/HVAC-equipment-controls/trane-lontalk-controllers/TechView.html

    A laptop with a serial port and a...
  8. Take at look at this FieldServer Document: ...

    Take at look at this FieldServer Document:

    http://www.fieldserver.com/docs/pdf/FS-8700-80_McQuay.pdf

    They have several OPM data maps in there.
  9. Thread: Trane Lon to AX

    by t-reck
    Replies
    15
    Views
    742

    You will have much more reliable performance with...

    You will have much more reliable performance with the proper terminating resistors installed.
  10. Thread: Trane Lon to AX

    by t-reck
    Replies
    15
    Views
    742

    The location of the repeater should not have a...

    The location of the repeater should not have a bearing on the retrofit, if they were communicating with the BCU properly then the Jace should be able to talk to them. The repeater is transparent to...
  11. Replies
    4
    Views
    384

    Check the AOP jumper to be sure they are in the V...

    Check the AOP jumper to be sure they are in the V position not the I position. Also, the AOPs (and AIPs) are not connected to either side of the 24V supply, it could be a common ground issue between...
  12. Replies
    3
    Views
    267

    The phone numbers are in Communications > BCU >...

    The phone numbers are in Communications > BCU > Phone Book
  13. Thread: Touch Screen

    by t-reck
    Replies
    17
    Views
    1,009

    I have tested although not used on a job yet...

    I have tested although not used on a job yet using an Android Tablet via ethernet connection. You have to use a Tablet that has a full featured USB port and a micro USB to ethernet adapter that is...
  14. Replies
    1
    Views
    260

    McQuay OPM Table for WSHPs

    Does anyone have a hex code table for the McQuay OPM data for WSHPs? I'm migrating the system from using a JCI MIG in between a Jace and the OPM. The HPs have microtech-I controllers. I have tested...
  15. Replies
    2
    Views
    299

    Thanks for the input. It's always difficult to...

    Thanks for the input. It's always difficult to estimate integration times when you've never touched a particular driver before.
  16. Replies
    2
    Views
    299

    AX with Siemens FLN Bus driver questions

    I'm looking for any input on using the Siemens FLN driver (Infocon I believe). We will be replacing an MBC that has devices on all 3 FLN busses. Does the driver license allow 3 ports to be used...
  17. Thread: Trane COMM3 CSC

    by t-reck
    Replies
    3
    Views
    386

    CSC Comm-3 is a supported controller on the...

    CSC Comm-3 is a supported controller on the standard Comm-3 link which should be supported on all versions of the BCU.
  18. Johnson MIG102 lost its configuration, need vct files

    I have a site with 2 Johnson MIG102-0 integrators. They both are configured for McQuay HPs. After an extended power failure, the lithium battery died on one of the MIGs. I can talk to both of them...
  19. Replies
    10
    Views
    855

    The PRV is probably setup as a minimum position...

    The PRV is probably setup as a minimum position control, typically used for an economizer damper. The EP solenoid may be tied to the fan starter to close the dampers when the fan is off.

    Of...
  20. Replies
    13
    Views
    882

    My 1st FX-60 job was very similar. A DX9100, a...

    My 1st FX-60 job was very similar. A DX9100, a few UNTs and 2 MIGs communicating with McQuay HPs w/Microtech-I controllers. MIGs communicate with McQuay bridges via RS232. Communication to MIGs is...
  21. Replies
    17
    Views
    1,720

    DCCA configuration is for changeover with NO...

    DCCA configuration is for changeover with NO auxiliary heat control. DCEA is intended for electric reheat. I believe the heat will be disabled if the RTU is in the heating mode. DCWA intended for...
  22. Replies
    17
    Views
    1,720

    The old Varitracs with the 25 pin connector do...

    The old Varitracs with the 25 pin connector do not have any handshaking control pins. A regular null cable or a 2-2, 3-3 and 5-7 cable (9-25 pin) will work.

    Baud rates were default at 1200 but...
  23. Oh, that was too easy! Thanks!

    Oh, that was too easy! Thanks!
  24. Exporting AlarmExtManager table to CSV or PDF in Niagara Workbench

    I am trying to generate a report to detail what points are being alarmed in the Station. The only export option when the AlarmExtManager is displayed is Export to Obix. I would like to generate a...
  25. Replies
    7
    Views
    1,042

    If the size of the system is not very large then...

    If the size of the system is not very large then you don't need the high capacity card. The high capacity card adds some stability to the Lon but you should be fine without it.

    Since you're only...