  1. Replies
    1
    Views
    580

    Right Angle Air Cleaner

    Hi guys, I'm planning on having a right angle air cleaner installed and wanted your opinions. The ones I'm looking at are the Trion Air Bear and GeneralAire MAC-L. The Air Bear says it acts like a...
  2. Replies
    311
    Views
    20,645

    OK, so how did you do that, X? You never stated...

    OK, so how did you do that, X? You never stated what modifications you've done to your house to reduce the heat gain that much. I'm guessing you have quite a few trees shading your house, but...
  3. Replies
    105
    Views
    7,458

    They replaced the TXV. Tech took readings, and...

    They replaced the TXV. Tech took readings, and left me with the following:

    OAT: 85 *F
    High: 205 psi
    Low: 79 psi
    SC: 13 *F
    SH: 15 *F

    The gurgling is gone at the valve now; it sounds like a...
  4. Yes. But would they have pro-status on...

    Yes. But would they have pro-status on hvac-talk.com? Regardless, that doesn't change my opinion that it should be open to everyone. Obviously that's still up to the admins here.
  5. Why would it need to be pro-member only? There...

    Why would it need to be pro-member only? There are probably some very insightful people out there (not just some regular bob, but ones who hold BPI certifications/etc. and do things like energy...
  6. Replies
    105
    Views
    7,458

    I've seen the "spaghetti monster" from another...

    I've seen the "spaghetti monster" from another thread. My system is nothing like that. The majority of the ductwork is metal. When the auditor took his TESP readings 2 Winters ago, he measured...
  7. Replies
    105
    Views
    7,458

    The garage gets hot on hot days. It usually runs...

    The garage gets hot on hot days. It usually runs about 5-10 degrees cooler than the outdoor temp. The LL temp is one degree cooler at the evap than it is at the condenser. I will try to get...
  8. Replies
    105
    Views
    7,458

    The lineset runs between the upstairs floor, and...

    The lineset runs between the upstairs floor, and garage ceiling. This is an area where a thermal bypass used to exist, but I have since sealed the area with EPS and spray foam. The lineset length...
  9. Replies
    105
    Views
    7,458

    Duh, I should have known that. As usual, the...

    Duh, I should have known that. As usual, the tech didn't write them down. The only readings I've gotten in writing from any of the companies I've had out is because I asked them to write them down.
  10. Replies
    105
    Views
    7,458

    The ones on the first page would be the ones...

    The ones on the first page would be the ones taken when the SH and SC readings were taken.

    Since the superheat dropped to 10 when the bulb was put into the warm water, that shows the valve is...
  11. Replies
    105
    Views
    7,458

    Any ideas on my last TXV question, shophound?

    Any ideas on my last TXV question, shophound?
  12. Replies
    105
    Views
    7,458

    Sorry guys, I've been out-of-town the past few...

    Sorry guys, I've been out-of-town the past few days.



    Not like it makes a huge difference, but I'm at 948 feet in elevation. So it'd be:

    1405 CFM x 4.35 x 6.18 = 37770.6 / 12000 = 3.14...
  13. Replies
    105
    Views
    7,458

    TXV isn't adjusted, and unfortunately, the bulb...

    TXV isn't adjusted, and unfortunately, the bulb isn't replaceable. Bulb is replaceable on some commercial TXVs, right? Seems dumb to me that the charge in the bulb could go bad (for whatever...
  14. Replies
    105
    Views
    7,458

    Hopefully that answers all of your questions. :)

    Hopefully that answers all of your questions. :)
  15. Replies
    105
    Views
    7,458

    That's correct. No zoning or manual dampers...

    That's correct. No zoning or manual dampers either, unfortunately.
  16. Replies
    105
    Views
    7,458

    Sorry, I'm not sure I follow. The main return...

    Sorry, I'm not sure I follow. The main return trunk is 20" x 12" and the panned returns feed it. I have six 8"x16" (l/w of return grilles) and one 8" x 32" panned returns feeding the main return...
  17. Replies
    105
    Views
    7,458

    I live close to Kansas City. The joists are 16"...

    I live close to Kansas City. The joists are 16" on center. The panned joists downstairs go up the wall to meet the main return trunk. The panned joists upstairs go down to meet the main return...
  18. Replies
    105
    Views
    7,458

    I've attached the extended performance data for...

    I've attached the extended performance data for my system to this post. Here are the numbers for the A/C equipment:

    Brand: Armstrong Air
    Condensing Unit: 2SCU13LE142P
    Coil: EC1P43CM
    TXV...
  19. Replies
    105
    Views
    7,458

    Thanks for all the insight. My house is a slab,...

    Thanks for all the insight. My house is a slab, so no basement or crawl space.

    I'm not sure if you saw my earlier post (this thread is starting to get really long), but I measured the airflow...
  20. Replies
    105
    Views
    7,458

    Hey shophound. Are you saying that you think...

    Hey shophound. Are you saying that you think there's a problem with the CFM going across the e-coil, or being delivered to the supply registers?

    What pictures would you like? I have a total of 4...
  21. Replies
    105
    Views
    7,458

    When the subcooling was at 10 degrees, there was...

    When the subcooling was at 10 degrees, there was gurgling at the TXV and the superheat was 30 degrees. He added more refrigerant and the subcooling went to 18 degrees and superheat down to 18...
  22. Replies
    105
    Views
    7,458

    The point I was making in noting all of the...

    The point I was making in noting all of the things I've done to improve the home, is that I've slowly reduced both sensible and latent loads on the system, but since I've started doing those things,...
  23. Replies
    105
    Views
    7,458

    Airflow

    The company that was out last week called me back and said that they think it is the TXV. I asked them if they wanted to come back out and check airflow before condemning it, and they responded that...
  24. Replies
    105
    Views
    7,458

    Hopefully those of you who post to this site...

    Hopefully those of you who post to this site understand how misinformed tipsrfine is, and that he's more interested in trying to start fights than learn. There are so many bullsh!t lies in his post,...
  25. Replies
    105
    Views
    7,458

    I was just outside a little while ago and...

    I was just outside a little while ago and measured 88.5 *F 6" from the condenser fins, and 108.0 discharge. However, I didn't note the indoor temp/RH at that time. The unit is 13-seer. Hopefully...