Search:

Type: Posts; User: porttss

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Replies
    9
    Views
    1,541

    Does any one have the datamate basic soft ware...

    Does any one have the datamate basic soft ware ,you can ,e mail to me at Email Address Removed, I,ll buy you a beer if I ever ran into you at the local pub
  2. Replies
    16
    Views
    2,182

    CW I would like to Thank you on the help you gave...

    CW I would like to Thank you on the help you gave me on my problem , I know you know much more about these things then I do, I do know them low ambient fan blades can cause a lot of recirculation I...
  3. Thread: RTAA-300

    by porttss
    Replies
    32
    Views
    1,562

    Thanks Graham for responding, I went through the...

    Thanks Graham for responding, I went through the service bulletin RTAA-SB-18 and everything seems to fit, at 70% RLA and lower, at times this thing seemed to work, a few weeks ago, also very high...
  4. Thread: RTAA-300

    by porttss
    Replies
    32
    Views
    1,562

    Just an update ,I manually through the gauges fed...

    Just an update ,I manually through the gauges fed suction pressor for unload and head to load, no problens loading and unloading. Where ever I stopped the value held (RLA), so I believe the main...
  5. Thread: RTAA-300

    by porttss
    Replies
    32
    Views
    1,562

    after reading through this sb I think I was right...

    after reading through this sb I think I was right the 1st time without knowing it , I had it narrowed down to either pill filter or lip seal after reading through this sb , then I remembered, I was...
  6. Thread: RTAA-300

    by porttss
    Replies
    32
    Views
    1,562

    OK THIS SB EXPLAINS IT THIS IS WHAT I WAS LOOKING...

    OK THIS SB EXPLAINS IT THIS IS WHAT I WAS LOOKING FOR THANK YOU TIM
  7. Thread: RTAA-300

    by porttss
    Replies
    32
    Views
    1,562

    One more question the term lip seal bypass I did...

    One more question the term lip seal bypass I did not want to bypass that which was all ready there,I thought this was the replacement parts for the load and unload assembly less the coils , I...
  8. Thread: RTAA-300

    by porttss
    Replies
    32
    Views
    1,562

    Then if I use my gauges to load and unload the...

    Then if I use my gauges to load and unload the piston via the suction port and the oil port and it works I can rule out the slide valve, Isolate the comp. check pill filters , and throw them out , I...
  9. Thread: RTAA-300

    by porttss
    Replies
    32
    Views
    1,562

    Thanks Graham, I will let you know how it goes ,...

    Thanks Graham, I will let you know how it goes , hope you did not mind my attempt at comedy. TIM
  10. Thread: RTAA-300

    by porttss
    Replies
    32
    Views
    1,562

    On this particular comp. I was not looking to...

    On this particular comp. I was not looking to reinvent the wheel, I assumed from info I got on this web site it replaced the part,s of this load and unload assembly, minus the coils. On the kit...
  11. Thread: RTAA-300

    by porttss
    Replies
    32
    Views
    1,562

    I ordered the kit but did not get it yet , It...

    I ordered the kit but did not get it yet , It states that it does have valves,VAL02843 and x13320327010 2 of each TIM
  12. Thread: RTAA-300

    by porttss
    Replies
    32
    Views
    1,562

    Yes one at a time , Thanks again TIM

    Yes one at a time , Thanks again TIM
  13. Thread: RTAA-300

    by porttss
    Replies
    32
    Views
    1,562

    Yes it is magnetised, but still no unload, I am...

    Yes it is magnetised, but still no unload, I am going to put gauge,s on that shrader tomorrow, and make sure it loads and unloads with me sending these pressures there via the manifold gauges from...
  14. Thread: RTAA-300

    by porttss
    Replies
    32
    Views
    1,562

    I,m kinda wondering did you guys read my post?...

    I,m kinda wondering did you guys read my post? I,ll go over this again I put 110 v to the load and unload solenoids The RLA went up but not down , the cond. coil s are clean and the dp switch is ok ,...
  15. Thread: RTAA-300

    by porttss
    Replies
    32
    Views
    1,562

    I,m getting a little confused I thought this ,kit...

    I,m getting a little confused I thought this ,kit just rebuilt what was allready there,on the one comp. it loads fine it just does not unload, I,m pretty sure it is most likely just the unload...
  16. Thread: RTAA-300

    by porttss
    Replies
    32
    Views
    1,562

    Thanks Graham for you input , I just started...

    Thanks Graham for you input , I just started working on these chillers because the guy that was, failed miseribly, On No#1 chiller there was a broken wire feeding 2 fans,blowing fuses ,on chiller 2,...
  17. Thread: RTAA-300

    by porttss
    Replies
    32
    Views
    1,562

    CW thanks a lot for answering. Before I left work...

    CW thanks a lot for answering. Before I left work today I noticed another compressor that was not unloading, on crt 2 C. There has not been a shrader put on the port yet so I will have to do this 1st...
  18. Thread: RTAA-300

    by porttss
    Replies
    32
    Views
    1,562

    I just seen in the manual this option is disabled...

    I just seen in the manual this option is disabled on are arrangement,and the half flow blade must not have been intened to be on there in the 1st place. Any input on this would be appreciated , and...
  19. Thread: RTAA-300

    by porttss
    Replies
    32
    Views
    1,562

    RTAA-300

    Does any one have any SB related to this machine? Any would be appreciated ,I need to do a lip seal by pass so sb 18 would be helpful also sb4 ,sb-12 and anything on the fans , Also Can I replace...
Results 1 to 19 of 31