  1. Replies
    24
    Views
    1,585

    All txv pins are made of stainless steel,but all...

    All txv pins are made of stainless steel,but all the gunk is collecting where the pressure drop is taking place.
  2. Replies
    8
    Views
    378

    GM engines produce so much crap, they clog the...

    GM engines produce so much crap, they clog the oil pickup strainer. I even ran mobil 1, clog at 275000 miles.
  3. Replies
    27
    Views
    909

    Since they changed their model #S differentiating...

    Since they changed their model #S differentiating units became a pain. The SY model comes as a Quiet cube and a remote same with the Indigo.
  4. Thread: c-frame motors

    by ararams
    Replies
    13
    Views
    711

    Toward the copper bar

    Toward the copper bar
  5. Replies
    27
    Views
    909

    Be careful when recovering refrigerant from those...

    Be careful when recovering refrigerant from those machines. Without power to the liquid line solenoid valve refrigerant is trapped at the drier.
  6. Replies
    27
    Views
    909

    It seems that the building has three phase power...

    It seems that the building has three phase power supply. If true,you do not want the machine to be on the high leg if one is present.
  7. Replies
    124
    Views
    5,947

    Can a clock/timer be added? This plus recording...

    Can a clock/timer be added? This plus recording event can help find troublesome intermittent problems.
  8. Replies
    41
    Views
    2,653

    Your boss thought his initial donation to the...

    Your boss thought his initial donation to the German economy was enough, not so .If he need those vans running he have to make some more donation with each part that carries the Benz symbol.
  9. Replies
    612
    Views
    106,040

    Earlier this week I had to drive an hour plus one...

    Earlier this week I had to drive an hour plus one way for a new unit not cooling only to find the thermostat set on heat. Invoice ---- closed open low voltage circuit.
  10. Normally a rack has the equipment to handle the...

    Normally a rack has the equipment to handle the backup of liquid before it hits the compressor,on single units it's a death sentence for that compressor.
  11. I hope you don't have an aftermarket accumulator.

    I hope you don't have an aftermarket accumulator.
  12. Did you replace the low pressure control with a...

    Did you replace the low pressure control with a new one? I ask this because there was a change in the setting. You are most likely working on a 2000 lb unit
  13. Replies
    31
    Views
    1,257

    There is a reason all machines have model...

    There is a reason all machines have model numbers,without it we don't know witch unit you are looking at.
  14. Replies
    2
    Views
    342

    May be the instructions are in Japanese and no...

    May be the instructions are in Japanese and no one can read it .
  15. Replies
    14
    Views
    2,134

    That's the biggest split system I have seen.

    That's the biggest split system I have seen.
  16. Replies
    25
    Views
    2,351

    Have you checked the discharge temp? Maybe the...

    Have you checked the discharge temp? Maybe the oil has started cooking. This is common with r22 systems with run away superheat,the same can happen with 410a or any refrigerant for that matter.
  17. If the arms are getting cold, how are the the...

    If the arms are getting cold, how are the the legs.
  18. Replies
    36
    Views
    5,222

    Stupidity has no borders nor language barriers.

    Stupidity has no borders nor language barriers.
  19. Replies
    21
    Views
    955

    I also think he's looking at a headmaster. ...

    I also think he's looking at a headmaster. As for the cooler (where the owner turns off the fans) I normally install a relay or contactor with a coil voltage similar to the evaporator fans in a...
  20. Thread: accumulators

    by ararams
    Replies
    3
    Views
    278

    Some have them on the bottom and they sometime...

    Some have them on the bottom and they sometime leak for no apparent reason.
  21. Replies
    5
    Views
    347

    Does the compressor have a decal saying it is...

    Does the compressor have a decal saying it is protecting itself by not pumping?
  22. Most if not all the products in there are package...

    Most if not all the products in there are package products, low humidity will not really affect quality. High humidity will definitely affect your beer because if it"s slimy, slips out of your hands...
  23. Thread: Whistling TXV

    by ararams
    Replies
    10
    Views
    871

    That whistling noise you are hearing is the...

    That whistling noise you are hearing is the universal language txv speaks, the oscillating part comes when the pressure varies with the fan cycle control. When a valve is well fed it's quiet but the...
  24. Replies
    10
    Views
    700

    You already have your amp meter in your...

    You already have your amp meter in your hand,continue using it to check how much amps is drawn by the run and the start windings. If they are both pulling amperage then you have good windings but a...
  25. That's exactly how I look at it because we are...

    That's exactly how I look at it because we are looking at a failed part.