  1. Replies
    6
    Views
    311

    N2 to Ethernet convertion?

    I have a high school with an older Johnson system that has the N2 comm wire run underground to the various buildings. The problem is the underground conduit is always getting full of water & messing...
  2. Replies
    1
    Views
    191

    IBSMS driver for Microsmart controllers

    I believe the IBSMS driver is for Robert Shaw MicroSmart controllers.
  3. Replies
    21
    Views
    3,308

    Worked fine for me

    I used Problocks for over 2 years without any real problems, so I am inclined to use it again. The only real problem I had was it didn't completely back up the OSS blocks, it didn't pull in the...
  4. Replies
    21
    Views
    3,308

    I know this thread has been dead for quite awhile...

    I know this thread has been dead for quite awhile but my company had decided to start working on Network 8000. Since I used to work on Network 8000 many years ago I have been tasked with getting a...
  5. Replies
    35
    Views
    2,609

    I would be grateful for a copy of your guide....

    I would be grateful for a copy of your guide. Thanks in advance.
  6. Replies
    1
    Views
    229

    TAC's ASD driver has an object (labelled PSI)...

    TAC's ASD driver has an object (labelled PSI) that has to be installed in the station for PSI to work on the ASD bus.
  7. Replies
    281
    Views
    43,836

    Windows XP was the last version of windows that...

    Windows XP was the last version of windows that any software was made for Network 8000.
  8. Replies
    11
    Views
    1,428

    The K-factor is a fudge factor to get correct air...

    The K-factor is a fudge factor to get correct air flow. It will be different for identical vav boxes because of the ducting. In real life you do not find the recommended 5 to 10 duct diameters of...
  9. Replies
    10
    Views
    1,470

    Where can I find a copy of NUDL?

    Where can I find a copy of NUDL?
  10. Replies
    3
    Views
    462

    Control Man, That may all be well & good, I...

    Control Man,
    That may all be well & good, I realize all good (and not so good things) must come to an end. I don't thing my ex boss was bsing me. He tends to be a bit colorful in his descriptions....
  11. Replies
    3
    Views
    462

    Another Network 8000 Request

    I worked for an Invesys distributor 4 or 5 years ago. My new employer has a number of sites with Network 8000 & wants me to take care of them. I tried contacting the local Shneider Electric dealer,...
  12. Replies
    10
    Views
    1,264

    When I was working at Siemens I would use the...

    When I was working at Siemens I would use the following procedure.
    1. Set P to a large & probably outrageous value, I & D set to zero.
    2. Adjust P down until you get the smallest P value without...
  13. Replies
    9
    Views
    1,327

    Can't find my old CD's

    I can't find my old Insight CD's :(, I haven't worked for Siemens in a quite a while, but I was able to look up the application guide for VAV TEC's on the internet & point 58 is the point to change...
  14. Replies
    9
    Views
    1,327

    Depends on the TEC Application

    What application is the TEC using? Check the application point list. If you can change the action there will be a binary point to change the action. You should then be able to change the action from...
  15. Replies
    6
    Views
    1,495

    Probably Low On RAM

    I haven't worked on Siemens equipment in 5 years now & I haven't worked on their BACNet equipment :rolleyes: but what you describe sounds like the panel is low on RAM. The panel is probably rebooting...
  16. Replies
    13
    Views
    912

    Extra Code

    Check to see if there is an object called PSI in the R2. This is required because the ASD driver did not allow for PSI (as a second master) originally. I'm not sure if it is required for tunneling...
  17. Replies
    18
    Views
    1,360

    Your com port should be COM1 or COM2. PSI is a...

    Your com port should be COM1 or COM2. PSI is a DOS program & so can only see those 2 com ports.
  18. Replies
    7
    Views
    860

    GCM Conversion

    You might want to look at Smartware Tech. They are a TAC (formally Invesys, ect. dealer). The claim to be able to convert your GCM database to a R2 data base, for a fee of course. It would be...
  19. Replies
    7
    Views
    824

    RS-485 Driver

    Since your system originally had a GCM & the problem has been around since the UNC was installed, it could be an ASD wiring issue. When Invensys gave Tridium their specs for the RS-485 hardware in...
  20. Replies
    15
    Views
    2,451

    A Possibility

    There is a possibility you have a corrupted node table. It has been a few years since I was at Siemens but let me see if I can explain it. If any of the MEC's & PCX were added to the BLN from one of...
  21. Replies
    2
    Views
    445

    Need the point list

    You need the point list from McQuay. Alerton is bacnet so they do not control the points McQuay chooses to show the system. The board might be a gateway from McQuay's proprietary communications &...
  22. Thread: Siemens FLN

    by Ex-Man
    Replies
    4
    Views
    1,262

    TEC & UC's Oh My

    Siemens TECs have their programs burned into EEPROM at the factory & you can't change them. They use a points list of 0-99. Included are the TEC address, the application number, and the rest are...
  23. Too Old?

    It could be they don't want to deal with a front end as old as yours. Since you mention Powers I am guessing your front end is using at best Win95, more likely Win3.1. They may not have anyone...
  24. Replies
    281
    Views
    43,836

    Network 8000 Programming Manuals

    I have a job coming up that will be replacing 2 GCM's with Jaces using the ASD driver. I need a copys of the GCM, MicroZone2 & PEM programming manuals. Can anyone help me here. I worked for an...
  25. Replies
    7
    Views
    1,507

    In the GCM

    Everything you see on the Signal screen is happening in the GCM. You need to figure out your GCM programming to figure out what is going on.