Seeking Professional Refrigeration Technicians for Chapel Hill, North Carolina Area
Come join our family at Boer Brothers Heating and Cooling. You can never have too many brothers. We are inviting... -
02-15-2012, 06:49 PM
Thread: WaterFurnace Geothermal Change Out
by brybo nc- Replies
- 15
- Views
- 1,986
Thanks,I might take you up on that.
Thanks,I might take you up on that.
-
12-18-2011, 07:54 PM
Thread: WaterFurnace Geothermal Change Out
by brybo nc- Replies
- 15
- Views
- 1,986
I am always impressed with your videos, nice...
I am always impressed with your videos, nice installs too. I think that we will start doing this and posting on our website.
Bryan -
10-21-2011, 04:33 PM
Thread: blooming chocolate? how do we stop this.
by brybo nc- Replies
- 9
- Views
- 570
Thanks for the reply. There are several...
Thanks for the reply.
There are several different kinds in the cases and three of them recommend temps the 65-68 degree range. these cases are for short term storage
BTW the store does have high... -
10-21-2011, 09:32 AM
Thread: blooming chocolate? how do we stop this.
by brybo nc- Replies
- 9
- Views
- 570
Thanks for the replies. I think that what has...
Thanks for the replies.
I think that what has happened is that there were 4) 45 min. off cycle defrosts on the candy circuit that were programmed in when we replaces the controller for the rack. I... -
10-19-2011, 03:15 PM
Thread: blooming chocolate? how do we stop this.
by brybo nc- Replies
- 9
- Views
- 570
blooming chocolate? how do we stop this.
Hey guys,
I have a few Barker cases that are set to 67 degrees 3 diff and 50% humidity (recommended settings) that are blooming the chocolate (condensing water on the tops of the $7.00 per piece... -
08-02-2011, 06:09 AM
Thread: Geo loop question:
by brybo nc- Replies
- 3
- Views
- 1,446
If it is that slow of a leak, try some loop...
If it is that slow of a leak, try some loop conditioner or a non-pressurized flow center.
Bryan -
08-02-2011, 05:54 AM
Thread: 650 foot well?
by brybo nc- Replies
- 7
- Views
- 1,738
The original well was for potable water for the...
The original well was for potable water for the house and it just did not hit enough water so we are trying to make lemonade out of this lemon.
-
08-02-2011, 05:51 AM
Thread: 650 foot well?
by brybo nc- Replies
- 7
- Views
- 1,738
the one gpm number is for the unusable 650ft...
the one gpm number is for the unusable 650ft water well that we would change to a closed loop 8-9 gpm well. (one loop, pressurized and grouted top to bottom)
-
08-01-2011, 08:02 PM
Thread: 650 foot well?
by brybo nc- Replies
- 7
- Views
- 1,738
650 foot well?
I have a house that I am getting ready to install a 038 ttv climatemaster at, the house has a 2.4 ton cooling load and I was planning on using two 300ft vertical wells with one inch pipe. The water...
-
09-01-2009, 09:05 PM
- Replies
- 2
- Views
- 1,053
ERV VS. ventilating dehumidifier (humid south)
So I had made up my mind that ventilating dehumidifiers are the way to go for tight houses in my area that require a fresh air vent, but I now have a builder that wants to use ERV's. what do you guys...
-
06-12-2009, 07:15 PM
Thread: hydro heat tax credits
by brybo nc- Replies
- 2
- Views
- 324
hydro heat tax credits
does anyone know if there are any hydro/dx fan coil match ups that achieve 16 seer?
-
05-30-2009, 06:44 AM
Thread: heatcraft clearance reduction
by brybo nc- Replies
- 3
- Views
- 499
Yes I was needing a letter from heatcraft for a...
Yes I was needing a letter from heatcraft for a city inspector. I got one from heatcraft for 18''. They gave it to me because I was elevating the units on racks and there would be airflow from below....
-
05-28-2009, 07:35 PM
Thread: heatcraft clearance reduction
by brybo nc- Replies
- 3
- Views
- 499
heatcraft clearance reduction
Any one ever get a letter from heatcraft saying that it would be OK to face the coil on a condenser 18'' from the wall instead of the width of the unit 38'' from the wall. I just cant fit it that far...
-
03-10-2009, 08:54 PM
- Replies
- 4
- Views
- 487
Aldridge seems like a pretty good company. Never...
Aldridge seems like a pretty good company. Never knew anyone that worked there but they seem to do good work.
-
03-08-2009, 11:23 PM
Thread: Help with new AC and Furnace Choice
by brybo nc- Replies
- 14
- Views
- 962
That's just not necessary, I've put in all of...
That's just not necessary, I've put in all of those including trane and there all fine. You have been tranewashed!
-
03-08-2009, 07:02 PM
Thread: water treatment for ice machine
by brybo nc- Replies
- 9
- Views
- 507
Bingo, allot of micro brews. How well does the...
Bingo, allot of micro brews. How well does the Mani self cleaning thing do? any treatments for yeast?
-
03-08-2009, 02:31 PM
Thread: water treatment for ice machine
by brybo nc- Replies
- 9
- Views
- 507
water treatment for ice machine
I have got a Manitowoc that has a pre filter and two charcoal filters that is just plane slimy. Are there any companies that will test the water and design a filter-anti slime system for you? I have...
-
03-08-2009, 01:58 PM
Thread: New Spring 2009 It's here
by brybo nc- Replies
- 13
- Views
- 451
It sure is a beautiful weekend. Keep up the...
It sure is a beautiful weekend. Keep up the positive attitude. It is obvious to me that your a survivor!
B:) -
03-07-2009, 06:43 PM
Thread: 95% Goodman installation
by brybo nc- Replies
- 23
- Views
- 3,001
nice paperwork holder, great job all around!
nice paperwork holder, great job all around!
-
03-07-2009, 06:16 PM
- Replies
- 16
- Views
- 4,553
Hey bud, welcome to the site. I'm one of the...
Hey bud, welcome to the site. I'm one of the "Brothers" that calls you for advice from time to time;) It will be good to have another expert opinion on here.
-
03-07-2009, 05:51 PM
Thread: 17 seer from a 14 seer A/C?
by brybo nc- Replies
- 9
- Views
- 573
The Heil 14 seer 2 1/2 ton heat pump with...
The Heil 14 seer 2 1/2 ton heat pump with variable speed blower I just sold is a 16seer match. It seems like the three ton units (Heil, Trane) seem to match up better than the 2, 4, and 5 ton.
-
02-21-2009, 03:44 PM
Thread: NC HVAC Licensing App question
by brybo nc- Replies
- 6
- Views
- 507
You better say you were an installer.
You better say you were an installer.
-
02-15-2009, 12:39 PM
Thread: New Yellow Jacket Digital Gauges??
by brybo nc- Replies
- 26
- Views
- 1,911
Is ACR out of North Carolina going to sell the...
Is ACR out of North Carolina going to sell the dsra's. They are a great supplier to work with. (at least from a costumers standpoint.)
B -
02-11-2009, 07:14 PM
Thread: 2009 Energy tax credits
by brybo nc- Replies
- 27
- Views
- 2,292
Go Carolina! Duke Sucks!
Go Carolina! Duke Sucks!
Results 1 to 25 of 250