  1. hey man how's that store looking so far. Did they...

    hey man how's that store looking so far. Did they tie a water tower to it or just VSR condensers....
  2. Replies
    16
    Views
    1,103

    I'm thinking this is a product issue and not a...

    I'm thinking this is a product issue and not a Refri problem....i have graphed these cases for over 5 days and its like clock work they don't hit 50* idk
  3. Replies
    16
    Views
    1,103

    The fans that are in this case are that ECM motor...

    The fans that are in this case are that ECM motor and blade combo they are black i forgot the exact name of it
  4. Replies
    16
    Views
    1,103

    yes it does and i don't lose any airflow at all....

    yes it does and i don't lose any airflow at all. At first i thought my coil was frosting up right before defrost but that wasn't the case
  5. Replies
    16
    Views
    1,103

    not that i have seen or smelled

    not that i have seen or smelled
  6. Replies
    16
    Views
    1,103

    I have thought of that cause out of all the cases...

    I have thought of that cause out of all the cases in this store this is the only line up with the issue. I have called HP and they have assured me i've got the right motor package
  7. Replies
    16
    Views
    1,103

    there is a staging area in the stock room where...

    there is a staging area in the stock room where the conditions are good as well
  8. Replies
    16
    Views
    1,103

    Odd Beer Case issue

    Ok i got a 24ft line up of Beer( Hill O5DM Case) the issue that im having is i'm getting some mold on the Beer packages.
    My case setpoint is 36* my rack is 404a +20SST. I've played with 3 defrost a...
  9. Thread: CPC

    by gatorfan9606
    Replies
    11
    Views
    1,332

    [QUOTE=Pounds;15435531]Does anyone know the part#...

    [QUOTE=Pounds;15435531]Does anyone know the part# for the ribbon cable that connects the PIB Board to the main processor board?. Can't find # anywhere online.[/QUOTh
    That's for an E2 is that what...
  10. Thread: CPC

    by gatorfan9606
    Replies
    11
    Views
    1,332

    i use the cpc-637-4801 noise abatement kit

    i use the cpc-637-4801 noise abatement kit
  11. Replies
    98
    Views
    10,549

    (R438a) is been used alot in the A/C conversions...

    (R438a) is been used alot in the A/C conversions down here in the big supermarket chains and 407a for racks it was R422d but that faded quick..
  12. Replies
    5
    Views
    599

    agree with jp its an excellent 3 or 5 day class....

    agree with jp its an excellent 3 or 5 day class. Copeland is always updating there equipment and components
  13. Replies
    16
    Views
    2,030

    Agree 100% there 3ways are not very srvc-able

    Agree 100% there 3ways are not very srvc-able
  14. Replies
    11
    Views
    1,473

    i have found the wires going to the 3 way valve...

    i have found the wires going to the 3 way valve or DDR valve with a short at the connector i have never had a bad control breaker your going to have to chase the common wire and see if you can find...
  15. Replies
    0
    Views
    550

    CX400 & FSD

    i have a cx that is not finding the fsd panel i have a cat 5. cable going to it now should the i.p on the fsd be minus 1 of the i.p prefix or the same as the i.p at the cx
  16. Thread: 404a/507

    by gatorfan9606
    Replies
    10
    Views
    999

    maybe 407-c??

    maybe 407-c??
  17. Thread: 404a/507

    by gatorfan9606
    Replies
    10
    Views
    999

    never heard of 507c i have heard of 507 and i...

    never heard of 507c i have heard of 507 and i have never changed gas on a ice machine if its been running on 507 why change???
  18. i have an 88ao board that does what you have we...

    i have an 88ao board that does what you have we have 2 cond set up's on the E2 one controls the ec motor with 1set of pressures the 2nd controls the standard motors with another pressure control...
  19. Replies
    10
    Views
    1,534

    so we're are using temp control instead of...

    so we're are using temp control instead of pressure?under the set up or are we using differential
  20. Replies
    29
    Views
    2,837

    thx for explaining it might have to try this

    thx for explaining it might have to try this
  21. Replies
    29
    Views
    2,837

    just a question phase.why would you want other...

    just a question phase.why would you want other circuits to run the float while the lead circuit is in defrost?when it comes out of defrost the float would be to high and now the that circuit is going...
  22. Replies
    29
    Views
    2,837

    if i understand you correctly if i set my suction...

    if i understand you correctly if i set my suction stpt to 14# and my min on the float to 16# and my delay every 5mins at 10mins it will start to go up to 16# i think im over thinking this lol
  23. Replies
    29
    Views
    2,837

    i agree with you 100% the min. should match the...

    i agree with you 100% the min. should match the suction setpoint for some reason i don't think the float app will not work if it doesn't match i could be wrong thats why i asked anytime i set one up...
  24. Replies
    11
    Views
    1,413

    we've been dealing with this problem for a very...

    we've been dealing with this problem for a very long time at one point T thought we were full of $*** now they just sent us 200 of those gaskets not fun replacing them either you almost need a troll...
  25. Replies
    29
    Views
    2,837

    ok i got a question that its been explain to me...

    ok i got a question that its been explain to me 10 diff ways:when setting up a float app.on an E2 or RMCC and your suction set point is say 14# now under float set up under min-max do you start your...
  26. Replies
    18
    Views
    2,349

    whats controls the rack an E2?maybe short...

    whats controls the rack an E2?maybe short cycling??i dont have too many problems with this set up at all in the few stores that have it
  27. Replies
    10
    Views
    1,006

    well said if we just take the time to do the task...

    well said if we just take the time to do the task at hand calls will drop this trade isn't for everyone but this is just a fun,hard,kick in the butt job and you learn everyday
  28. Replies
    14
    Views
    1,147

    i have ran a new lineset behind the cabinet it...

    i have ran a new lineset behind the cabinet it has worked well and only used 10oz
  29. Replies
    23
    Views
    1,808

    or pee in a gatorade bottle thinking the other...

    or pee in a gatorade bottle thinking the other guy was done drinking!!! it
    both guys got fired for fighting in the store
  30. Replies
    12
    Views
    855

    jaybee yes if the comm. voltage is bad i would...

    jaybee yes if the comm. voltage is bad i would check the ccb before or the p.i.b on D port or B port if you have an E2 i have seen ccb's do some odd stuff
  31. Replies
    29
    Views
    2,072

    Are you guys getting training classes in the west...

    Are you guys getting training classes in the west coast??cause i havent heard of any in the east for C02 glycol been taking off like crazy in my area
  32. Replies
    4
    Views
    534

    good point^ check the dipswitch

    good point^ check the dipswitch
  33. Replies
    4
    Views
    534

    what is your D.B? are you on standard or enhance...

    what is your D.B? are you on standard or enhance suction? are your H.P settings the same for are the pumps ?i know E2 likes big numbers under H.P like the mbtu/h of each pump etc....(imo)
  34. Replies
    7
    Views
    600

    your one lucky guy to have 3 stores i got 30+...

    your one lucky guy to have 3 stores i got 30+ what i did was run another ultrasite with 4.7 and i renamed the files
  35. Replies
    7
    Views
    600

    yes i did but i didnt notice it saying anything...

    yes i did but i didnt notice it saying anything about rmc's?so..your saying you can view rmc offline? i had techsupport also verify this and they couldnt either view rmc's
  36. Replies
    50
    Views
    3,103

    jp let us know what you come up with this is got...

    jp let us know what you come up with this is got me thinking.....
  37. Replies
    7
    Views
    600

    ultrasite-fyi

    the new ultrasite software 4.81 does not read rmc's offline nor does it let you restore them some ver of rmcc's are having the same problem and i was told you can't downgrade which when i get home i...
  38. Replies
    20
    Views
    1,957

    i will tell you this if stores would put back...

    i will tell you this if stores would put back into there stores that would be great am doing remodels now where they're not replacing 15-20yr old copper pipe we used to upgrade compressors and A/C's...
  39. Replies
    20
    Views
    1,957

    i love it when they cant hit superheat and leave...

    i love it when they cant hit superheat and leave the tev wide open and ask for a new valve and the screen was cloged!!ugh during startup i clean all the screens within 24&48hrs along with the...
  40. Replies
    20
    Views
    1,957

    i agree!!

    i agree!!
  41. Replies
    9
    Views
    889

    i have done that i have used actual amps i have...

    i have done that i have used actual amps i have used btu/h etc on the 4D nothing seems to have settled i have ran that abandon option want to give it a fair chance so far am seen more run time out of...
  42. Replies
    9
    Views
    889

    nevermind i had to log in under level 5 to see it

    nevermind i had to log in under level 5 to see it
  43. Replies
    9
    Views
    889

    where is this enable abandoned option am on...

    where is this enable abandoned option am on ultrasite and cant find it?
  44. Replies
    9
    Views
    889

    tightest control and am going to log on to my...

    tightest control and am going to log on to my store and check out that option of the enable abandoned
  45. Replies
    9
    Views
    889

    enhanced suction/E2

    i've got a rack with an E2 (2.72f01) that always picks on one compressor all the time
    i have played with the h.p i have deleted and added the group again and i can come back with -in 48hrs and its...
  46. Replies
    10
    Views
    1,379

    drill

    drill
  47. Replies
    3
    Views
    1,093

    nevermind after searching there new nightmare...

    nevermind after searching there new nightmare site i found it
  48. Replies
    3
    Views
    1,093

    C.T i see that it said E2 2.81 but if am correct...

    C.T i see that it said E2 2.81 but if am correct the web site has 2.72 as its latest??am i missing something
  49. Replies
    3
    Views
    1,474

    i think i ran in to this and my sensors went bad...

    i think i ran in to this and my sensors went bad have you checked the transduser??
  50. Replies
    32
    Views
    2,396

    (imo) tif zx is very good we have lower the...

    (imo) tif zx is very good we have lower the amount of gas we been dumping into these racks for years the tif can pick up a bee fart lol its that good the down fall is the sensor!i dont know why but...